Five test voltages: 50, 100, 250, 500 and 1000VDC.
Actual test voltages display.
Insulation resistance up to 20 G Ohm.
Automatic discharge after finished test.
AC and DC voltage measurement.
Frequency measurement.
Low resistance with 0.01 Ohm resolution.
Test lead resistance compensation .
Low test current for fast resistance measurement on inductive
loads.
Automatic polarity reversal for increased accuracy.
1000 memory locations, RS232 output, computer
Auto power off.
Self contained, rugged industrial case.
One year warranty parts and labour.
Technical Specification:
Insulation:
Test
voltages: 50, 100, 250, 500 and 1000V DC
Range:
0 to 200 M Ohm, 0 to 20 G Ohm on 500 and 1000V
Basic
Accuracy: 3% of reading
Resistance:
Range:
0 to 2000 Ohm
Resolution:
0.01 Ohm
Basic
Accuracy: 2% of reading
Continuity:
Range:
0 to 2000 Ohm, low test current for inductive loads
Resolution:
0.1 Ohm
Basic
Accuracy: 5% of reading
Voltage:
Range:
0 to 600 V AC and DC
Resolution:
1 V
Basic
Accuracy: 3% of reading
Included
accessories
Test
probe, push on clip and prod, instruction manual
Optional
PC software(Note:
software is password protected, require serial number of instrument
before being installed) with RS232 cable, soft carry case,
battery charger with a set of 4 pcs NiCd rechargeable batteries