STAR3 Digital Energy and Harmonics
Analyzer
For single phase and unbalanced three phase systems
Volt (RMS), Amp (RMS), P.F., kW, kVA, kWh, Hz
SUPERIOR PERFORMANCE
- Digital Energy and Harmonics Analyzer
96*96
- True RMS measurement
- Displays 52 values and 352 measures
for model with harmonics
- Unbalanced three phase systems delta
or star, bi-phase, single phase
- High accuracy : Voltage, Current and
Power error <0.5%
- Bright back-lighted red numbers on
dark background LCD display. It is visible in any
lighting conditions also from long distance
- Cogeneration Counters
- Total harmonic distortion factor per
phase
- Alarm, pulses and analogue outputs
- RS485 communication port included
in all models
- Multi-protocol interface
- Easy and extremely flexible Set up
menu including CT and VT ratios selection
- Password protection for setup and
resets
- Model with three phase Harmonic Analysis
up to the 25th order and 352 measures
- 3 years warranty period
|
|
| This
high quality 96x96 panel energy analyser provides brilliant
features at a price never reached before.
The new bright red LCD display, the harmonic
analysis , the wide set of measured parameters including the
THD available in all the models, the multi-protocol capability
of the RS485 port and the high accuracy class 0.5%, the 3
years-warranty period, allow to consider the STAR3 the new
state of art of the panel analysers market. It is a perfect,
professional and low cost solution for the electrical panels,
sub-metering systems, OEM applications, supervisory systems,
Building and Factory automation systems.
The high flexibility of the instrument
makes it adaptable to totally different applications. The
model with harmonics allows a permanent based control of one
of the most important aspect of the power supply quality.
Such important possibility, up to now, was reserved only to
high-cost device. The STAR3 breaks this price barrier bringing,
for the first time, the harmonic analysis into the market
of the panel analysers
|
|
|
3ph TOT
|
L1
|
L2
|
L3
|
Neutral
|
|
Voltage
|
Ö
|
Ö
|
Ö
|
Ö
|
|
|
Phase-phase voltage
|
|
L1-L2
|
L2-L3
|
L3-L1
|
|
|
Current
|
Ö
|
Ö
|
Ö
|
Ö
|
Ö
|
|
Power factor
|
Ö
|
Ö
|
Ö
|
Ö
|
|
|
Frequency
|
|
Ö
|
|
|
|
|
Current Avg
|
|
Ö
|
Ö
|
Ö
|
|
|
Current
maximum demand
|
|
Ö
|
Ö
|
Ö
|
|
|
|
|
|
|
|
|
|
KW
|
Ö
|
Ö
|
Ö
|
Ö
|
|
|
KVAr
|
Ö
|
Ö
|
Ö
|
Ö
|
|
|
kVA
|
Ö
|
Ö
|
Ö
|
Ö
|
|
|
kW Avg
|
Ö
|
|
|
|
|
|
kVAr Avg
|
Ö
|
|
|
|
|
|
kVA Avg
|
Ö
|
|
|
|
|
|
kW maximum demand
|
Ö
|
|
|
|
|
|
kVA
maximum demand
|
Ö
|
|
|
|
|
|
|
|
|
|
|
|
|
kWh imported +
|
Ö
|
|
|
|
|
|
kWh exported -
|
Ö
|
|
|
|
|
|
kVArh leading +
|
Ö
|
|
|
|
|
|
kVArh lagging -
|
Ö
|
|
|
|
|
|
|
|
|
|
|
|
|
THD Current
|
Ö
|
Ö
|
Ö
|
Ö
|
|
|
THD Voltage
|
Ö
|
Ö
|
Ö
|
Ö
|
|
|
Four models available:
1) STAR3
Basic model. It shows all the measures listed in the above table.
Includes an RS485 output with multi-protocol capability: Modbus RTU,
Modbus IEEE and Modbus ASCII . The importance of the communication
and the lower cost of the components allow today the inclusion of
the RS485 port as a default features.
Even if you are not interested in making a network of instruments,
this possibility will remains always available for future developments.
2) STAR3 ALM:
as the basic model+ two relay outputs. The outputs can be set be
for either alarms signalling or pulses or remote relay control.
The function "alarm" can be associated with several measures including
V,A,W,THD and harmonics. Each relay has a maximum and a minimum
threshold, the histeresys and the delay time. All the settings can
be adjusted. If used in "pulse" mode the relays generate pulses
proportional to the associated measures. Also in this case the behaviour
is adjustable with the setup menu. In "remote control" the position
of the relay is decided by an external master device (PLC, PC, etc)
through the RS485 line . This is very convenient for load shedding
application.
3) STAR3 4-20mA:
as the basic model + two analogue outputs 4-20 mA or 0-20 mA.
4) STAR3 HARMO:
as Star3 ALM+ three phase harmonics spectrum for voltage and current.
In addition to the basic measures of the above table, the harmonics
model displays complete information about the spectrum.
Technical Specifications:
Maximum dimensions (mm): instrument:
96 X 96 X 115.4. Cut-out template: 91 X 91
Power supply: from network 230 V or 115 V +15%-20% @ 35÷400
Hz (4 VA).
Display: reverse red LCD with LED backlight
Voltmeter inputs: VL1, VL2, VL3, N up to 430 V phase-neutral, 750
V phase-to-phase, 35÷400 Hz
Voltmeter input impedance: 2 Mohm
Voltage input overload: max 850 V phase-neutral
Current inputs: AL1, AL2, AL3, COM. , consumption 1 VA. Three or
two 5A external curr.transf. required
Measuring range: 0-120% In
Sensitivity: current 20 mA ; voltage 10 mV
Overcurrent :withstand 50 amps for 1 min.
Number of scales: 1 voltage scale, 2 current scales
Measurements: True R.M.S. up to25th harmonic = 1250Hz with fundamental
@50 Hz
Sampling frequency: 2.5 kHz.
Accuracy: <0.5% for Voltage and current and Power
Connection: Single phase or three phase star, three phase delta,
or diphase systems
Weight : 0.6 Kg
Protection level: instrument IP20, front panel IP40
Temperature range: -10°C ÷ + 50°C
Relative humidity range :(R.H.): from 20% to 90%.
Condensation: non condensing.
|
For your price and delivery enquires, application details,
comments and general feedback,
please feel free to use our Feedback
Mailbox
|
PDF
Brochure
|
 |
Last modified April, 2006.
|