EM 6400 Digital Power Analyzer


These state-of-the-art, true RMS, 3- line display multi-function meters can be used in Control Panels, Motor Control Centers and Genset Panels. The models in this series are characterized by their rugged construction, compact size, and low installation costs.
 


Features

  • Global: UL,CUL Listed, CE, C-Tick certified
  • Accuracy Class 1.0 (0.5 Option)
  • EC 61036 / CBIP 88
  • True RMS, Accurate on Distorted waveforms
  • Simultaneous sampling of Volts & Amps
  • Low PT, CT burden
  • Crisp, Bright Display
  • View 3 Parameters together
  • Auto Scaling from Kilo to Mega to Giga
  • Programmable CT, PT ratios
  • Built-in phase analyser
  • Quick and easy installation
  • Auto Scrolling
  • Communication with PCs, PLCs, DCS through optional RS 485 Serial Port
  • 10 year back-up of integrated data
  • Tamper Proof Cover option
  • Sealed dust-proof construction
  • Simplest to operate - One touch key
  • Measures 4 Quadrant Power & 2 Quadrant Energy (IE option measures 4 Quadrant Energy)
  • Monitors Demand (Option)

TECHNICAL CHARACTERISTICS

Sensing/Measuement True RMS, 1 sec update time, 4 Quadrant Power & Energy
Accuracy(Wh) Class 1.0 as per IEC 62052-11,62053-23, class 0.5(optional) as per IEC62052-11, 62053-22 and ANSI C12.20
Input Voltage 4 voltage input(V1, V2, V3, Vn) 110 or 415V L-L nominal (Range 80 to 600V L-L)

Aux Supply

44 - 300V ac/dc
Input Current Current inputs(A1,A2, A3) 20mA -6A (Field configurable 1A or 5A)
Overload 10A max continuous, 50A max for 3 seconds
Burden 0.2VA max per Volts/Amps input, 3VA on Auxiary Supply
Frequency 45 - 65 Hz
Resolution RMS 4 digit, INTEG 8 digit
Communication RS485 serial channel connection Industry standard Modbus RTU protocol
Isolation 2000 volts ac isolation for one minute between communication and other circuits
Demand Integration period multiple of 5 minutes from 5 to 30 minutes 15 sec update time
Safety Measurement category III, Pollution Degree 2, Protection against shock by double insulation at user accessible area
Environmental Operating Temperature -10°C to 60°C, Storage Temperature -25°C to 70°C Humidity 5% to 95% non condensing
Weight 400 gms approx. unpacked, 500 grms approx. shipping
Warranty 2 years from date of invoice(Canada & USA only)
Optional Accuracy CL 0.5, Demand, Import/Export, THD