{"title":"Insulation Testers (Megger-Style Insulation Resistance Meters) Up to 20kV","description":"\u003ch2 data-end=\"278\" data-start=\"197\"\u003eInsulation Testers You Can Trust – Digital, High Voltage, and CSA-Certified\u003c\/h2\u003e\n\u003cp data-end=\"626\" data-start=\"280\"\u003eExplore our selection of professional \u003cstrong data-end=\"340\" data-start=\"318\"\u003einsulation testers\u003c\/strong\u003e designed for electrical contractors, maintenance technicians, and industrial users across Canada. Whether you're performing routine testing or troubleshooting insulation breakdowns, we offer trusted models from leading brands including \u003cstrong data-end=\"587\" data-start=\"577\"\u003eMetrel\u003c\/strong\u003e, \u003cstrong data-end=\"597\" data-start=\"589\"\u003eAEMC\u003c\/strong\u003e, \u003cstrong data-end=\"610\" data-start=\"599\"\u003eSeaward\u003c\/strong\u003e, and \u003cstrong data-end=\"625\" data-start=\"616\"\u003eFluke\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"672\" data-start=\"628\"\u003eFrom \u003cstrong data-end=\"650\" data-start=\"633\"\u003e1 kV to 15 kV\u003c\/strong\u003e, our lineup includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"753\" data-start=\"675\"\u003e\n\u003cstrong data-end=\"705\" data-start=\"675\"\u003eDigital insulation testers\u003c\/strong\u003e with advanced data logging and display features\u003c\/li\u003e\n\u003cli data-end=\"826\" data-start=\"756\"\u003e\n\u003cstrong data-end=\"791\" data-start=\"756\"\u003eHigh voltage insulation testers\u003c\/strong\u003e for heavy-duty and substation work\u003c\/li\u003e\n\u003cli data-end=\"875\" data-start=\"829\"\u003e\n\u003cstrong data-end=\"847\" data-start=\"829\"\u003eCompact models\u003c\/strong\u003e ideal for field inspections\u003c\/li\u003e\n\u003cli data-end=\"939\" data-start=\"878\"\u003e\n\u003cstrong data-end=\"903\" data-start=\"878\"\u003eCSA-certified testers\u003c\/strong\u003e that meet Canadian safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1146\" data-start=\"941\"\u003eEvery model is backed by expert support from our Canadian team. Need help choosing? We're happy to recommend the best insulation tester for your voltage range, test application, or compliance requirements.\u003c\/p\u003e\n\u003chr data-end=\"1151\" data-start=\"1148\"\u003e\n\u003ch3 data-end=\"1177\" data-start=\"1153\"\u003eCommon Applications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"1208\" data-start=\"1180\"\u003eIndustrial plant maintenance\u003c\/li\u003e\n\u003cli data-end=\"1239\" data-start=\"1211\"\u003eElectrical panel inspections\u003c\/li\u003e\n\u003cli data-end=\"1265\" data-start=\"1242\"\u003eCable and motor testing\u003c\/li\u003e\n\u003cli data-end=\"1313\" data-start=\"1268\"\u003eAcceptance testing and predictive maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1454\" data-start=\"1315\"\u003eWe carry everything from \u003cstrong data-end=\"1379\" data-start=\"1340\"\u003e1000V insulation resistance testers\u003c\/strong\u003e to \u003cstrong data-end=\"1412\" data-start=\"1383\"\u003e15kV digital megohmmeters\u003c\/strong\u003e—in stock and ready to ship across Canada.\u003c\/p\u003e\n\u003chr data-end=\"1459\" data-start=\"1456\"\u003e\n\u003cp data-end=\"1501\" data-start=\"1461\"\u003e\u003cstrong\u003e🔎 Looking for a specific voltage range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"1501\" data-start=\"1461\"\u003e🔹   \u003ca href=\"https:\/\/duncaninstr.com\/collections\/1000v-insulation-testers\"\u003e1,000V Insulation Testers\u003c\/a\u003e\u003cbr data-start=\"606\" data-end=\"609\"\u003e🔹   \u003ca href=\"https:\/\/duncaninstr.com\/collections\/2500v-insulation-testers\"\u003e2,500V Insulation Testers\u003c\/a\u003e\u003cbr data-start=\"640\" data-end=\"643\"\u003e🔹   \u003ca href=\"https:\/\/duncaninstr.com\/collections\/5000v-insulation-testers\"\u003e5,000V Insulation Testers\u003c\/a\u003e\u003cbr data-start=\"675\" data-end=\"678\"\u003e🔹 \u003ca href=\"https:\/\/duncaninstr.com\/collections\/10000v-insulation-testers\"\u003e10,000V Insulation Testers\u003c\/a\u003e\u003cbr\u003e🔹 \u003ca href=\"https:\/\/duncaninstr.com\/collections\/15000v-insulation-testers\"\u003e15,000V Insulation Testers\u003c\/a\u003e\u003ca data-start=\"681\" data-end=\"714\" class=\"\" rel=\"noopener\" href=\"#\"\u003e\u003c\/a\u003e\u003cbr data-start=\"714\" data-end=\"717\"\u003e🔹 \u003ca href=\"https:\/\/duncaninstr.com\/collections\/20000v-insulation-testers\"\u003e20,000V Insulation Testers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-end=\"2129\" data-start=\"1959\"\u003eStill comparing options? Read our \u003ca href=\"#\" rel=\"noopener\" class=\"\" data-end=\"2028\" data-start=\"1993\"\u003eInsulation Tester Buying Guide\u003c\/a\u003e to understand the differences between analog vs. digital models, voltage ranges, and accuracy specs.\u003c\/p\u003e\n\u003chr data-end=\"2134\" data-start=\"2131\"\u003e\n\u003ch2 data-end=\"2173\" data-start=\"2136\"\u003eWhy Order from Duncan Instruments?\u003c\/h2\u003e\n\u003cul data-end=\"2336\" data-start=\"2175\"\u003e\n\u003cli data-end=\"2216\" data-start=\"2175\"\u003e\n\u003cp data-end=\"2216\" data-start=\"2177\"\u003e🇨🇦 Canadian company, established 1968\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2257\" data-start=\"2217\"\u003e\n\u003cp data-end=\"2257\" data-start=\"2219\"\u003e⚡ Expert support from real technicians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2290\" data-start=\"2258\"\u003e\n\u003cp data-end=\"2290\" data-start=\"2260\"\u003e🚚 Fast shipping across Canada\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2336\" data-start=\"2291\"\u003e\n\u003cp data-end=\"2336\" data-start=\"2293\"\u003e📞 Talk to us before or after your purchase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"mi3202","title":"Metrel MI 3202 Gigaohm – 5kV High-Voltage Insulation Resistance Teste","description":"\u003cp data-start=\"267\" data-end=\"340\" class=\"\"\u003e\u003cstrong data-start=\"267\" data-end=\"340\"\u003eAdvanced Diagnostic Insulation Tester with PI\/DAR and USB Data Export\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"342\" data-end=\"802\" class=\"\"\u003e\u003cstrong data-start=\"342\" data-end=\"363\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"363\" data-end=\"366\"\u003eThe \u003cstrong data-start=\"370\" data-end=\"396\"\u003eMetrel MI 3202 Gigaohm\u003c\/strong\u003e is a \u003cstrong data-start=\"402\" data-end=\"446\"\u003e5kV digital insulation resistance tester\u003c\/strong\u003e designed for \u003cstrong data-start=\"460\" data-end=\"508\"\u003eadvanced high-voltage insulation diagnostics\u003c\/strong\u003e in power utilities, heavy industry, and electrical infrastructure. With selectable test voltages up to 5000 V and insulation resistance measurements up to \u003cstrong data-start=\"664\" data-end=\"673\"\u003e10 TΩ\u003c\/strong\u003e, this tester offers unmatched precision for critical equipment such as transformers, cables, switchgear, and rotating machinery.\u003c\/p\u003e\n\u003cp data-start=\"804\" data-end=\"1057\" class=\"\"\u003eEquipped with \u003cstrong data-start=\"818\" data-end=\"845\"\u003ePolarization Index (PI)\u003c\/strong\u003e and \u003cstrong data-start=\"850\" data-end=\"887\"\u003eDielectric Absorption Ratio (DAR)\u003c\/strong\u003e testing, as well as \u003cstrong data-start=\"908\" data-end=\"939\"\u003eUSB data export and logging\u003c\/strong\u003e, the MI 3202 is ideal for technicians who demand high accuracy, detailed reporting, and dependable field performance.\u003c\/p\u003e\n\u003chr data-start=\"1059\" data-end=\"1062\" class=\"\"\u003e\n\u003ch3 data-start=\"1064\" data-end=\"1085\" class=\"\"\u003e\u003cstrong data-start=\"1068\" data-end=\"1085\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1086\" data-end=\"1577\"\u003e\n\u003cli data-start=\"1086\" data-end=\"1150\" class=\"\"\u003e\n\u003cp data-start=\"1088\" data-end=\"1150\" class=\"\"\u003e\u003cstrong data-start=\"1088\" data-end=\"1106\"\u003eTest Voltages:\u003c\/strong\u003e 50 V to 5000 V (adjustable in 25 V steps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1151\" data-end=\"1211\" class=\"\"\u003e\n\u003cp data-start=\"1153\" data-end=\"1211\" class=\"\"\u003e\u003cstrong data-start=\"1153\" data-end=\"1185\"\u003eInsulation Resistance Range:\u003c\/strong\u003e Up to 10 TΩ (10,000 GΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1212\" data-end=\"1275\" class=\"\"\u003e\n\u003cp data-start=\"1214\" data-end=\"1275\" class=\"\"\u003e\u003cstrong data-start=\"1214\" data-end=\"1234\"\u003ePI \u0026amp; DAR Testing\u003c\/strong\u003e – Essential for predictive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1276\" data-end=\"1332\" class=\"\"\u003e\n\u003cp data-start=\"1278\" data-end=\"1332\" class=\"\"\u003e\u003cstrong data-start=\"1278\" data-end=\"1309\"\u003eReal-Time Graphical Display\u003c\/strong\u003e of insulation trends\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1333\" data-end=\"1388\" class=\"\"\u003e\n\u003cp data-start=\"1335\" data-end=\"1388\" class=\"\"\u003e\u003cstrong data-start=\"1335\" data-end=\"1365\"\u003eInternal Memory + USB Port\u003c\/strong\u003e for easy data export\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1389\" data-end=\"1433\" class=\"\"\u003e\n\u003cp data-start=\"1391\" data-end=\"1433\" class=\"\"\u003e\u003cstrong data-start=\"1391\" data-end=\"1431\"\u003eAutomatic Discharge of Tested Object\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1434\" data-end=\"1475\" class=\"\"\u003e\n\u003cp data-start=\"1436\" data-end=\"1475\" class=\"\"\u003e\u003cstrong data-start=\"1436\" data-end=\"1473\"\u003eTimer and Ramp Test Functionality\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1476\" data-end=\"1529\" class=\"\"\u003e\n\u003cp data-start=\"1478\" data-end=\"1529\" class=\"\"\u003e\u003cstrong data-start=\"1478\" data-end=\"1527\"\u003eProtective Transport Case \u0026amp; Field-Ready Build\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1530\" data-end=\"1577\" class=\"\"\u003e\n\u003cp data-start=\"1532\" data-end=\"1577\" class=\"\"\u003e\u003cstrong data-start=\"1532\" data-end=\"1577\"\u003eSafety Rated to CAT IV 600 V \/ EN 61010-1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1579\" data-end=\"1582\" class=\"\"\u003e\n\u003ch3 data-start=\"1584\" data-end=\"1601\" class=\"\"\u003e\u003cstrong data-start=\"1588\" data-end=\"1601\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1602\" data-end=\"1791\"\u003e\n\u003cli data-start=\"1602\" data-end=\"1646\" class=\"\"\u003e\n\u003cp data-start=\"1604\" data-end=\"1646\" class=\"\"\u003eSubstations and utility grid maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1647\" data-end=\"1700\" class=\"\"\u003e\n\u003cp data-start=\"1649\" data-end=\"1700\" class=\"\"\u003eTransformer and motor manufacturing and servicing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1701\" data-end=\"1733\" class=\"\"\u003e\n\u003cp data-start=\"1703\" data-end=\"1733\" class=\"\"\u003eCable insulation diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1734\" data-end=\"1791\" class=\"\"\u003e\n\u003cp data-start=\"1736\" data-end=\"1791\" class=\"\"\u003ePredictive maintenance programs with data documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1793\" data-end=\"1796\" class=\"\"\u003e\n\u003ch3 data-start=\"1798\" data-end=\"1822\" class=\"\"\u003e\u003cstrong data-start=\"1802\" data-end=\"1822\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1823\" data-end=\"1998\"\u003e\n\u003cli data-start=\"1823\" data-end=\"1867\" class=\"\"\u003e\n\u003cp data-start=\"1825\" data-end=\"1867\" class=\"\"\u003eMetrel MI 3202 Gigaohm Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1868\" data-end=\"1906\" class=\"\"\u003e\n\u003cp data-start=\"1870\" data-end=\"1906\" class=\"\"\u003eHigh-voltage test leads and probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1907\" data-end=\"1940\" class=\"\"\u003e\n\u003cp data-start=\"1909\" data-end=\"1940\" class=\"\"\u003eUSB cable and Metrel software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1941\" data-end=\"1958\" class=\"\"\u003e\n\u003cp data-start=\"1943\" data-end=\"1958\" class=\"\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1959\" data-end=\"1974\" class=\"\"\u003e\n\u003cp data-start=\"1961\" data-end=\"1974\" class=\"\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1975\" data-end=\"1998\" class=\"\"\u003e\n\u003cp data-start=\"1977\" data-end=\"1998\" class=\"\"\u003eBatteries (installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2000\" data-end=\"2003\" class=\"\"\u003e\n\u003ch3 data-start=\"2005\" data-end=\"2032\" class=\"\"\u003e🔍 \u003cstrong data-start=\"2012\" data-end=\"2032\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2033\" data-end=\"2978\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2033\" data-end=\"2150\"\u003e\n\u003ctr data-start=\"2033\" data-end=\"2150\"\u003e\n\u003cth data-start=\"2033\" data-end=\"2065\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2065\" data-end=\"2090\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2067\" data-end=\"2085\"\u003eMetrel MI 3202\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2090\" data-end=\"2118\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2092\" data-end=\"2110\"\u003eKyoritsu 3125A\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2118\" data-end=\"2150\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2120\" data-end=\"2134\"\u003eFluke 1555\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2270\" data-end=\"2978\"\u003e\n\u003ctr data-start=\"2270\" data-end=\"2389\"\u003e\n\u003ctd data-start=\"2270\" data-end=\"2302\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2302\" data-end=\"2328\" data-col-size=\"sm\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2328\" data-end=\"2357\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2357\" data-end=\"2389\"\u003e10,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2390\" data-end=\"2509\"\u003e\n\u003ctd data-start=\"2390\" data-end=\"2422\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-start=\"2422\" data-end=\"2448\" data-col-size=\"sm\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-start=\"2448\" data-end=\"2477\" data-col-size=\"sm\"\u003e1 TΩ\u003c\/td\u003e\n\u003ctd data-start=\"2477\" data-end=\"2509\" data-col-size=\"sm\"\u003e2 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2510\" data-end=\"2626\"\u003e\n\u003ctd data-start=\"2510\" data-end=\"2542\" data-col-size=\"sm\"\u003ePI\/DAR Test Capability\u003c\/td\u003e\n\u003ctd data-start=\"2542\" data-end=\"2567\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2567\" data-end=\"2595\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2595\" data-end=\"2626\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2627\" data-end=\"2743\"\u003e\n\u003ctd data-start=\"2627\" data-end=\"2659\" data-col-size=\"sm\"\u003eGraphical Display\u003c\/td\u003e\n\u003ctd data-start=\"2659\" data-end=\"2684\" data-col-size=\"sm\"\u003e✅ Yes (real-time)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2684\" data-end=\"2712\"\u003e❌ No\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2712\" data-end=\"2743\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2744\" data-end=\"2860\"\u003e\n\u003ctd data-start=\"2744\" data-end=\"2776\" data-col-size=\"sm\"\u003eData Logging \u0026amp; Export\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2776\" data-end=\"2801\"\u003e✅ USB\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2801\" data-end=\"2829\"\u003e✅ (limited memory)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2829\" data-end=\"2860\"\u003e✅ USB\/PC Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2861\" data-end=\"2978\"\u003e\n\u003ctd data-start=\"2861\" data-end=\"2893\" data-col-size=\"sm\"\u003eBest Use\u003c\/td\u003e\n\u003ctd data-start=\"2893\" data-end=\"2922\" data-col-size=\"sm\"\u003eHigh-precision field + lab\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2922\" data-end=\"2946\"\u003eUtility field use\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2946\" data-end=\"2978\"\u003eExtended high-voltage testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Metrel","offers":[{"title":"Default Title","offer_id":1990792839212,"sku":"MTMI3202","price":2327.6,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/MTMI3202.png?v=1517503037"},{"product_id":"mi3201","title":"Metrel MI 3201 Teraohm 5kV Plus – High-Voltage Diagnostic Insulation Tester","description":"\u003cp\u003e\u003cspan\u003eMI 3201 TeraOhm 5 kV insulation tester is a portable instrument intended to measure insulation resistance through the use of high voltage DC test voltages up to 5 kV. The large LCD screen allows real-time R(t) graphs to be displayed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis insulation tester is also being sold as \u003ca rel=\"noopener noreferrer\" href=\"https:\/\/www.greenlee.com\/products\/Megohmmeter%2540c-5kV%2540c-Insulation-Tester.html\" target=\"_blank\"\u003eGreenlee 5990A\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMEASURING FUNCTIONS\u003c\/h3\u003e\n\u003cp data-start=\"284\" data-end=\"366\" class=\"\"\u003e\u003cstrong data-start=\"284\" data-end=\"366\"\u003eTop-Tier 5kV Insulation Resistance Tester with 10 TΩ Range and PC Connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"368\" data-end=\"788\" class=\"\"\u003e\u003cstrong data-start=\"368\" data-end=\"389\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"389\" data-end=\"392\"\u003eThe \u003cstrong data-start=\"396\" data-end=\"431\"\u003eMetrel MI 3201 Teraohm 5kV Plus\u003c\/strong\u003e is a high-end \u003cstrong data-start=\"446\" data-end=\"486\"\u003edigital insulation resistance tester\u003c\/strong\u003e designed for demanding industrial, utility, and laboratory environments. It offers \u003cstrong data-start=\"570\" data-end=\"618\"\u003eadjustable test voltages from 50 V to 5000 V\u003c\/strong\u003e and insulation resistance measurement up to \u003cstrong data-start=\"663\" data-end=\"672\"\u003e10 TΩ\u003c\/strong\u003e, making it ideal for advanced diagnostics of motors, generators, transformers, switchgear, and high-voltage cables.\u003c\/p\u003e\n\u003cp data-start=\"790\" data-end=\"1083\" class=\"\"\u003ePacked with features such as \u003cstrong data-start=\"819\" data-end=\"846\"\u003ePolarization Index (PI)\u003c\/strong\u003e and \u003cstrong data-start=\"851\" data-end=\"888\"\u003eDielectric Absorption Ratio (DAR)\u003c\/strong\u003e testing, \u003cstrong data-start=\"898\" data-end=\"919\"\u003egraphical display\u003c\/strong\u003e, and \u003cstrong data-start=\"925\" data-end=\"944\"\u003eUSB data export\u003c\/strong\u003e, the MI 3201 is built for professionals who need precise measurements, traceable results, and reliable performance under tough conditions.\u003c\/p\u003e\n\u003chr data-start=\"1085\" data-end=\"1088\" class=\"\"\u003e\n\u003ch3 data-start=\"1090\" data-end=\"1111\" class=\"\"\u003e\u003cstrong data-start=\"1094\" data-end=\"1111\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1112\" data-end=\"1610\"\u003e\n\u003cli data-start=\"1112\" data-end=\"1181\" class=\"\"\u003e\n\u003cp data-start=\"1114\" data-end=\"1181\" class=\"\"\u003e\u003cstrong data-start=\"1114\" data-end=\"1137\"\u003eTest Voltage Range:\u003c\/strong\u003e 50 V to 5000 V (adjustable in 25 V steps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1182\" data-end=\"1242\" class=\"\"\u003e\n\u003cp data-start=\"1184\" data-end=\"1242\" class=\"\"\u003e\u003cstrong data-start=\"1184\" data-end=\"1216\"\u003eInsulation Resistance Range:\u003c\/strong\u003e Up to 10 TΩ (10,000 GΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1243\" data-end=\"1315\" class=\"\"\u003e\n\u003cp data-start=\"1245\" data-end=\"1315\" class=\"\"\u003e\u003cstrong data-start=\"1245\" data-end=\"1265\"\u003ePI \u0026amp; DAR Testing\u003c\/strong\u003e – Predict insulation degradation before failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1316\" data-end=\"1361\" class=\"\"\u003e\n\u003cp data-start=\"1318\" data-end=\"1361\" class=\"\"\u003e\u003cstrong data-start=\"1318\" data-end=\"1359\"\u003eRamp Test and Step Voltage Test Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1362\" data-end=\"1413\" class=\"\"\u003e\n\u003cp data-start=\"1364\" data-end=\"1413\" class=\"\"\u003e\u003cstrong data-start=\"1364\" data-end=\"1411\"\u003eReal-Time Graphical Display of Test Results\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1414\" data-end=\"1479\" class=\"\"\u003e\n\u003cp data-start=\"1416\" data-end=\"1479\" class=\"\"\u003e\u003cstrong data-start=\"1416\" data-end=\"1446\"\u003eUSB Port + Metrel Software\u003c\/strong\u003e for data download and analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1480\" data-end=\"1526\" class=\"\"\u003e\n\u003cp data-start=\"1482\" data-end=\"1526\" class=\"\"\u003e\u003cstrong data-start=\"1482\" data-end=\"1524\"\u003eAutomatic Discharge of Capacitive Load\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1527\" data-end=\"1564\" class=\"\"\u003e\n\u003cp data-start=\"1529\" data-end=\"1564\" class=\"\"\u003e\u003cstrong data-start=\"1529\" data-end=\"1562\"\u003eRobust Carrying Case Included\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1565\" data-end=\"1610\" class=\"\"\u003e\n\u003cp data-start=\"1567\" data-end=\"1610\" class=\"\"\u003e\u003cstrong data-start=\"1567\" data-end=\"1610\"\u003eCAT IV 600 V Safety Rating (EN 61010-1)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1612\" data-end=\"1615\" class=\"\"\u003e\n\u003ch3 data-start=\"1617\" data-end=\"1634\" class=\"\"\u003e\u003cstrong data-start=\"1621\" data-end=\"1634\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1635\" data-end=\"1833\"\u003e\n\u003cli data-start=\"1635\" data-end=\"1676\" class=\"\"\u003e\n\u003cp data-start=\"1637\" data-end=\"1676\" class=\"\"\u003eSubstation and power grid maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1677\" data-end=\"1727\" class=\"\"\u003e\n\u003cp data-start=\"1679\" data-end=\"1727\" class=\"\"\u003eTransformer and high-voltage motor diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1728\" data-end=\"1783\" class=\"\"\u003e\n\u003cp data-start=\"1730\" data-end=\"1783\" class=\"\"\u003eIndustrial insulation audits and compliance testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1784\" data-end=\"1833\" class=\"\"\u003e\n\u003cp data-start=\"1786\" data-end=\"1833\" class=\"\"\u003eManufacturers performing type and routine tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1835\" data-end=\"1838\" class=\"\"\u003e\n\u003ch3 data-start=\"1840\" data-end=\"1864\" class=\"\"\u003e\u003cstrong data-start=\"1844\" data-end=\"1864\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1865\" data-end=\"2031\"\u003e\n\u003cli data-start=\"1865\" data-end=\"1900\" class=\"\"\u003e\n\u003cp data-start=\"1867\" data-end=\"1900\" class=\"\"\u003eMetrel MI 3201 Teraohm 5kV Plus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1901\" data-end=\"1928\" class=\"\"\u003e\n\u003cp data-start=\"1903\" data-end=\"1928\" class=\"\"\u003eHigh-voltage test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1929\" data-end=\"1962\" class=\"\"\u003e\n\u003cp data-start=\"1931\" data-end=\"1962\" class=\"\"\u003eUSB cable and Metrel software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1963\" data-end=\"1980\" class=\"\"\u003e\n\u003cp data-start=\"1965\" data-end=\"1980\" class=\"\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1981\" data-end=\"2003\" class=\"\"\u003e\n\u003cp data-start=\"1983\" data-end=\"2003\" class=\"\"\u003eInstruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2004\" data-end=\"2031\" class=\"\"\u003e\n\u003cp data-start=\"2006\" data-end=\"2031\" class=\"\"\u003eBatteries (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2033\" data-end=\"2036\" class=\"\"\u003e\n\u003ch3 data-start=\"2038\" data-end=\"2065\" class=\"\"\u003e🔍 \u003cstrong data-start=\"2045\" data-end=\"2065\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2066\" data-end=\"3032\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2066\" data-end=\"2185\"\u003e\n\u003ctr data-start=\"2066\" data-end=\"2185\"\u003e\n\u003cth data-start=\"2066\" data-end=\"2100\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2100\" data-end=\"2127\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2102\" data-end=\"2120\"\u003eMetrel MI 3201\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2127\" data-end=\"2154\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2129\" data-end=\"2147\"\u003eMetrel MI 3202\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2154\" data-end=\"2185\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2156\" data-end=\"2170\"\u003eFluke 1555\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2309\" data-end=\"3032\"\u003e\n\u003ctr data-start=\"2309\" data-end=\"2430\"\u003e\n\u003ctd data-start=\"2309\" data-end=\"2343\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2343\" data-end=\"2371\" data-col-size=\"sm\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2371\" data-end=\"2399\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2399\" data-end=\"2430\"\u003e10,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2431\" data-end=\"2552\"\u003e\n\u003ctd data-start=\"2431\" data-end=\"2465\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-start=\"2465\" data-end=\"2493\" data-col-size=\"sm\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-start=\"2493\" data-end=\"2521\" data-col-size=\"sm\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2521\" data-end=\"2552\"\u003e2 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2553\" data-end=\"2671\"\u003e\n\u003ctd data-start=\"2553\" data-end=\"2587\" data-col-size=\"sm\"\u003ePI\/DAR Test Capability\u003c\/td\u003e\n\u003ctd data-start=\"2587\" data-end=\"2614\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2614\" data-end=\"2641\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2641\" data-end=\"2671\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2672\" data-end=\"2790\"\u003e\n\u003ctd data-start=\"2672\" data-end=\"2706\" data-col-size=\"sm\"\u003eGraphical Display\u003c\/td\u003e\n\u003ctd data-start=\"2706\" data-end=\"2733\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2733\" data-end=\"2760\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2760\" data-end=\"2790\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2791\" data-end=\"2909\"\u003e\n\u003ctd data-start=\"2791\" data-end=\"2825\" data-col-size=\"sm\"\u003eData Export\u003c\/td\u003e\n\u003ctd data-start=\"2825\" data-end=\"2852\" data-col-size=\"sm\"\u003e✅ USB\u003c\/td\u003e\n\u003ctd data-start=\"2852\" data-end=\"2879\" data-col-size=\"sm\"\u003e✅ USB\u003c\/td\u003e\n\u003ctd data-start=\"2879\" data-end=\"2909\" data-col-size=\"sm\"\u003e✅ USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2910\" data-end=\"3032\"\u003e\n\u003ctd data-start=\"2910\" data-end=\"2944\" data-col-size=\"sm\"\u003eBest Use\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2944\" data-end=\"2972\"\u003eHeavy industrial + lab\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2972\" data-end=\"3001\"\u003eUtility \u0026amp; field diagnostics\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3001\" data-end=\"3032\"\u003eUltra high-voltage testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"csc-default\" id=\"c7635\"\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated testing - PI, DD, DAR calculations with automated resistance ranging (AR). All data is displayed during one single measurement.\u003c\/li\u003e\n\u003cli\u003eFault finding - Fully programmable step voltage and withstanding voltage test functions to assist in diagnosing faults in insulation.\u003c\/li\u003e\n\u003cli\u003eR(t) graph - Real time resistance against time graph plotting facility to graphically illustrate the response of a material to an applied test voltage.\u003c\/li\u003e\n\u003cli\u003eFaster testing - High 5 mA charging current quickly charges capacitive loads.\u003c\/li\u003e\n\u003cli\u003eAccurate - Selectable noise rejection filters (up to 5 mA) and shielded cables as standard ensure accurate readings.\u003c\/li\u003e\n\u003cli\u003eSafe - High CAT IV, 600 V voltage protection\u003c\/li\u003e\n\u003cli\u003ePortable - Lightweight 3 kg design with carry handle and shoulder strap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eMI 3201 Standard set\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstrument TeraOhm 5 kV Plus\u003c\/li\u003e\n\u003cli\u003eSmall soft carrying bag\u003c\/li\u003e\n\u003cli\u003eMains cable\u003c\/li\u003e\n\u003cli\u003e10 kV shielded test lead, black, 2 m\u003c\/li\u003e\n\u003cli\u003e10 kV shielded test lead, red, 2 m\u003c\/li\u003e\n\u003cli\u003e10 kV crocodile clip, 2 pcs (black, red)\u003c\/li\u003e\n\u003cli\u003eGuard lead, green, 2 m\u003c\/li\u003e\n\u003cli\u003eCrocodile clip, green\u003c\/li\u003e\n\u003cli\u003e6 x 1.2 V NiMH rechargeable batteries, type C\u003c\/li\u003e\n\u003cli\u003eHandbook on CD\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDownload:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener noreferrer\" href=\"http:\/\/www.metrel.si\/fileadmin\/BAZA_od_Damijan_Dolinar\/Metrel\/PDF_dokumentacija\/Single_leaflets\/MI_3201_TeraOhm_5_kV_Plus\/Ang\/Single_2011_MI_3201TeraOhm_5_kV_Plus_Ang.pdf\" target=\"_blank\"\u003eDatasheet for MI 3201 TeraOhm 5kV Plus\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener noreferrer\" href=\"http:\/\/www.metrel.si\/fileadmin\/BAZA_od_Damijan_Dolinar\/Metrel\/PDF_dokumentacija\/Single_leaflets\/PC_SW_HVLink_PRO\/Ang\/HVLink_PRO.pdf\" target=\"_blank\"\u003eDatasheet PC SW HVLink Pro\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener noreferrer\" href=\"http:\/\/www.metrel.si\/fileadmin\/BAZA_od_Damijan_Dolinar\/Metrel\/Navodila_instrumentov\/Instruments\/MI_3201_TerOhm_5_kV_Plus\/Ang\/MI_3201_TeraOhm_5_kV_Plus_ANG_Ver_1.7_20_751_272.pdf\" target=\"_blank\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Metrel","offers":[{"title":"Default Title","offer_id":2163292471340,"sku":"MTMI3201","price":2598.2,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/MI_3201_TeraOhm_5_kV_Plus_side.jpg?v=1517876522"},{"product_id":"kyoritsu-3125a","title":"Kyoritsu 3125A – 5kV Digital High-Voltage Insulation Resistance Tester (Up to 1 TΩ)","description":"\u003cp class=\"\" data-end=\"342\" data-start=\"272\"\u003e\u003cstrong data-end=\"342\" data-start=\"272\"\u003eProfessional-Grade Megohmmeter for High-Voltage Electrical Testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"342\" data-start=\"272\"\u003e\u003cstrong data-end=\"342\" data-start=\"272\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eThe KEW 3125A is no longer available\u003c\/span\u003e, replaced by \u003ca href=\"https:\/\/duncaninstr.com\/products\/kyoritsu-kew-3125b\"\u003eKEW 3125B\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"770\" data-start=\"344\"\u003e\u003cstrong data-end=\"365\" data-start=\"344\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-end=\"368\" data-start=\"365\"\u003eThe \u003cstrong data-end=\"390\" data-start=\"372\"\u003eKyoritsu 3125A\u003c\/strong\u003e is a high-performance \u003cstrong data-end=\"457\" data-start=\"413\"\u003e5kV digital insulation resistance tester\u003c\/strong\u003e engineered for industrial and utility applications. With an insulation resistance range up to \u003cstrong data-end=\"572\" data-start=\"552\"\u003e1 TΩ (1 tera-ohm)\u003c\/strong\u003e and selectable test voltages from 250 V to 5000 V, this tester is ideal for checking insulation integrity in high-voltage equipment such as transformers, switchgear, cables, and rotating machinery.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1009\" data-start=\"772\"\u003eIts large LCD with bar graph, built-in memory, and intuitive interface make the 3125A a top-tier instrument for electrical engineers and maintenance professionals conducting regular testing and commissioning in high-voltage environments.\u003c\/p\u003e\n\u003chr class=\"\" data-end=\"1014\" data-start=\"1011\"\u003e\n\u003ch3 class=\"\" data-end=\"1037\" data-start=\"1016\"\u003e\u003cstrong data-end=\"1037\" data-start=\"1020\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1524\" data-start=\"1038\"\u003e\n\u003cli class=\"\" data-end=\"1097\" data-start=\"1038\"\u003e\n\u003cp class=\"\" data-end=\"1097\" data-start=\"1040\"\u003e\u003cstrong data-end=\"1058\" data-start=\"1040\"\u003eTest Voltages:\u003c\/strong\u003e 250 V, 500 V, 1000 V, 2500 V, 5000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1155\" data-start=\"1098\"\u003e\n\u003cp class=\"\" data-end=\"1155\" data-start=\"1100\"\u003e\u003cstrong data-end=\"1132\" data-start=\"1100\"\u003eInsulation Resistance Range:\u003c\/strong\u003e Up to 1 TΩ (1000 GΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1207\" data-start=\"1156\"\u003e\n\u003cp class=\"\" data-end=\"1207\" data-start=\"1158\"\u003e\u003cstrong data-end=\"1185\" data-start=\"1158\"\u003eAuto Discharge Function\u003c\/strong\u003e for operator safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1283\" data-start=\"1208\"\u003e\n\u003cp class=\"\" data-end=\"1283\" data-start=\"1210\"\u003e\u003cstrong data-end=\"1273\" data-start=\"1210\"\u003eDielectric Absorption Ratio (DAR) \u0026amp; Polarization Index (PI)\u003c\/strong\u003e testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1336\" data-start=\"1284\"\u003e\n\u003cp class=\"\" data-end=\"1336\" data-start=\"1286\"\u003e\u003cstrong data-end=\"1334\" data-start=\"1286\"\u003eLarge Backlit Digital Display with Bar Graph\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1388\" data-start=\"1337\"\u003e\n\u003cp class=\"\" data-end=\"1388\" data-start=\"1339\"\u003e\u003cstrong data-end=\"1386\" data-start=\"1339\"\u003eMemory for Data Storage (up to 43 readings)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1438\" data-start=\"1389\"\u003e\n\u003cp class=\"\" data-end=\"1438\" data-start=\"1391\"\u003e\u003cstrong data-end=\"1436\" data-start=\"1391\"\u003eTimer Function for Timed Insulation Tests\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1480\" data-start=\"1439\"\u003e\n\u003cp class=\"\" data-end=\"1480\" data-start=\"1441\"\u003e\u003cstrong data-end=\"1464\" data-start=\"1441\"\u003eOverload Protection\u003c\/strong\u003e on all ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1524\" data-start=\"1481\"\u003e\n\u003cp class=\"\" data-end=\"1524\" data-start=\"1483\"\u003e\u003cstrong data-end=\"1524\" data-start=\"1483\"\u003eIEC 61010-1 CAT IV 600 V Safety Rated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"\" data-end=\"1529\" data-start=\"1526\"\u003e\n\u003ch3 class=\"\" data-end=\"1548\" data-start=\"1531\"\u003e\u003cstrong data-end=\"1548\" data-start=\"1535\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1755\" data-start=\"1549\"\u003e\n\u003cli class=\"\" data-end=\"1595\" data-start=\"1549\"\u003e\n\u003cp class=\"\" data-end=\"1595\" data-start=\"1551\"\u003eHigh-voltage maintenance and commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1636\" data-start=\"1596\"\u003e\n\u003cp class=\"\" data-end=\"1636\" data-start=\"1598\"\u003eSubstation and power utility testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1692\" data-start=\"1637\"\u003e\n\u003cp class=\"\" data-end=\"1692\" data-start=\"1639\"\u003eTransformer, motor, and generator insulation checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1755\" data-start=\"1693\"\u003e\n\u003cp class=\"\" data-end=\"1755\" data-start=\"1695\"\u003eIndustrial reliability and predictive maintenance programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"\" data-end=\"1760\" data-start=\"1757\"\u003e\n\u003ch3 class=\"\" data-end=\"1786\" data-start=\"1762\"\u003e\u003cstrong data-end=\"1786\" data-start=\"1766\"\u003eWhat's Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1940\" data-start=\"1787\"\u003e\n\u003cli class=\"\" data-end=\"1827\" data-start=\"1787\"\u003e\n\u003cp class=\"\" data-end=\"1827\" data-start=\"1789\"\u003eKyoritsu 3125A 5kV Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1875\" data-start=\"1828\"\u003e\n\u003cp class=\"\" data-end=\"1875\" data-start=\"1830\"\u003eHigh-voltage test leads and alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1893\" data-start=\"1876\"\u003e\n\u003cp class=\"\" data-end=\"1893\" data-start=\"1878\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1916\" data-start=\"1894\"\u003e\n\u003cp class=\"\" data-end=\"1916\" data-start=\"1896\"\u003eInstruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1940\" data-start=\"1917\"\u003e\n\u003cp class=\"\" data-end=\"1940\" data-start=\"1919\"\u003eBatteries (installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"\" data-end=\"1945\" data-start=\"1942\"\u003e\n\u003ch3 class=\"\" data-end=\"1974\" data-start=\"1947\"\u003e🔍 \u003cstrong data-end=\"1974\" data-start=\"1954\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2972\" data-start=\"1975\"\u003e\n\u003cthead data-end=\"2097\" data-start=\"1975\"\u003e\n\u003ctr data-end=\"2097\" data-start=\"1975\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2008\" data-start=\"1975\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2034\" data-start=\"2008\"\u003e\u003cstrong data-end=\"2028\" data-start=\"2010\"\u003eKyoritsu 3125A\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2064\" data-start=\"2034\"\u003e\u003cstrong data-end=\"2051\" data-start=\"2036\"\u003eFluke 1550C\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2097\" data-start=\"2064\"\u003e\u003cstrong data-end=\"2084\" data-start=\"2066\"\u003eMetrel MI 3205\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2972\" data-start=\"2223\"\u003e\n\u003ctr data-end=\"2348\" data-start=\"2223\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2256\" data-start=\"2223\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-end=\"2283\" data-start=\"2256\" data-col-size=\"sm\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-end=\"2314\" data-start=\"2283\" data-col-size=\"sm\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-end=\"2348\" data-start=\"2314\" data-col-size=\"sm\"\u003e5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2474\" data-start=\"2349\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2382\" data-start=\"2349\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2409\" data-start=\"2382\"\u003e1 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2440\" data-start=\"2409\"\u003e1 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2474\" data-start=\"2440\"\u003e1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2597\" data-start=\"2475\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2508\" data-start=\"2475\"\u003eDAR\/PI Capability\u003c\/td\u003e\n\u003ctd data-end=\"2534\" data-start=\"2508\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-end=\"2564\" data-start=\"2534\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-end=\"2597\" data-start=\"2564\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2720\" data-start=\"2598\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2631\" data-start=\"2598\"\u003eInternal Memory\u003c\/td\u003e\n\u003ctd data-end=\"2657\" data-start=\"2631\" data-col-size=\"sm\"\u003e✅ Yes (43 readings)\u003c\/td\u003e\n\u003ctd data-end=\"2687\" data-start=\"2657\" data-col-size=\"sm\"\u003e✅ Yes (full logging)\u003c\/td\u003e\n\u003ctd data-end=\"2720\" data-start=\"2687\" data-col-size=\"sm\"\u003e✅ Yes (PC interface available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2846\" data-start=\"2721\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2754\" data-start=\"2721\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2781\" data-start=\"2754\"\u003eLCD + Bar Graph\u003c\/td\u003e\n\u003ctd data-end=\"2812\" data-start=\"2781\" data-col-size=\"sm\"\u003eLCD + Analog scale\u003c\/td\u003e\n\u003ctd data-end=\"2846\" data-start=\"2812\" data-col-size=\"sm\"\u003eLCD + Graphical Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2972\" data-start=\"2847\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2880\" data-start=\"2847\"\u003ePortability\u003c\/td\u003e\n\u003ctd data-end=\"2907\" data-start=\"2880\" data-col-size=\"sm\"\u003eCompact and rugged\u003c\/td\u003e\n\u003ctd data-end=\"2938\" data-start=\"2907\" data-col-size=\"sm\"\u003eLarger, rugged case\u003c\/td\u003e\n\u003ctd data-end=\"2972\" data-start=\"2938\" data-col-size=\"sm\"\u003eBench\/field hybrid unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kyoritsu","offers":[{"title":"Default Title","offer_id":6830601633836,"sku":"KEW3125","price":1452.2,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/KEW_3125_A_KYORITSU_5_kV_eristysvastusmittari_ml.gif?v=1536829433"},{"product_id":"kyoritsu-3127","title":"Kyoritsu 3127 – 5kV High-Voltage Digital Insulation Tester (Up to 10 TΩ)","description":"\u003cp data-start=\"282\" data-end=\"363\" class=\"\"\u003e\u003cstrong data-start=\"282\" data-end=\"363\"\u003eAdvanced 5kV Megohmmeter with Wide Resistance Range and Built-in Data Logging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"365\" data-end=\"805\" class=\"\"\u003e\u003cstrong data-start=\"365\" data-end=\"386\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"386\" data-end=\"389\"\u003eThe \u003cstrong data-start=\"393\" data-end=\"410\"\u003eKyoritsu 3127\u003c\/strong\u003e is a premium \u003cstrong data-start=\"424\" data-end=\"468\"\u003e5kV digital insulation resistance tester\u003c\/strong\u003e capable of measuring insulation resistance up to \u003cstrong data-start=\"518\" data-end=\"527\"\u003e10 TΩ\u003c\/strong\u003e, making it a top choice for \u003cstrong data-start=\"556\" data-end=\"616\"\u003eutility companies, high-voltage labs, and heavy industry\u003c\/strong\u003e. With selectable test voltages from 250 V to 5000 V, real-time graphical output, and onboard memory, the 3127 is designed for \u003cstrong data-start=\"743\" data-end=\"804\"\u003eprecision diagnostics and long-term insulation monitoring\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"807\" data-end=\"1003\" class=\"\"\u003eIdeal for motors, switchgear, cables, and high-voltage installations, it also features \u003cstrong data-start=\"894\" data-end=\"916\"\u003ePI and DAR testing\u003c\/strong\u003e, \u003cstrong data-start=\"918\" data-end=\"934\"\u003estep voltage\u003c\/strong\u003e, \u003cstrong data-start=\"936\" data-end=\"951\"\u003etimer modes\u003c\/strong\u003e, and \u003cstrong data-start=\"957\" data-end=\"977\"\u003eUSB connectivity\u003c\/strong\u003e for seamless data export.\u003c\/p\u003e\n\u003chr data-start=\"1005\" data-end=\"1008\" class=\"\"\u003e\n\u003ch3 data-start=\"1010\" data-end=\"1031\" class=\"\"\u003e\u003cstrong data-start=\"1014\" data-end=\"1031\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1032\" data-end=\"1509\"\u003e\n\u003cli data-start=\"1032\" data-end=\"1091\" class=\"\"\u003e\n\u003cp data-start=\"1034\" data-end=\"1091\" class=\"\"\u003e\u003cstrong data-start=\"1034\" data-end=\"1052\"\u003eTest Voltages:\u003c\/strong\u003e 250 V, 500 V, 1000 V, 2500 V, 5000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1092\" data-end=\"1152\" class=\"\"\u003e\n\u003cp data-start=\"1094\" data-end=\"1152\" class=\"\"\u003e\u003cstrong data-start=\"1094\" data-end=\"1126\"\u003eInsulation Resistance Range:\u003c\/strong\u003e Up to 10 TΩ (10,000 GΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1153\" data-end=\"1230\" class=\"\"\u003e\n\u003cp data-start=\"1155\" data-end=\"1230\" class=\"\"\u003e\u003cstrong data-start=\"1155\" data-end=\"1220\"\u003ePI (Polarization Index) and DAR (Dielectric Absorption Ratio)\u003c\/strong\u003e testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1231\" data-end=\"1291\" class=\"\"\u003e\n\u003cp data-start=\"1233\" data-end=\"1291\" class=\"\"\u003e\u003cstrong data-start=\"1233\" data-end=\"1260\"\u003eLarge Graphical Display\u003c\/strong\u003e with bar graph and backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1292\" data-end=\"1326\" class=\"\"\u003e\n\u003cp data-start=\"1294\" data-end=\"1326\" class=\"\"\u003e\u003cstrong data-start=\"1294\" data-end=\"1324\"\u003eStep Voltage \u0026amp; Timer Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1327\" data-end=\"1377\" class=\"\"\u003e\n\u003cp data-start=\"1329\" data-end=\"1377\" class=\"\"\u003e\u003cstrong data-start=\"1329\" data-end=\"1375\"\u003eUSB Port for Data Logging and PC Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1378\" data-end=\"1426\" class=\"\"\u003e\n\u003cp data-start=\"1380\" data-end=\"1426\" class=\"\"\u003e\u003cstrong data-start=\"1380\" data-end=\"1399\"\u003eInternal Memory\u003c\/strong\u003e for storing test results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1427\" data-end=\"1463\" class=\"\"\u003e\n\u003cp data-start=\"1429\" data-end=\"1463\" class=\"\"\u003e\u003cstrong data-start=\"1429\" data-end=\"1461\"\u003eAutomatic Discharge Function\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1464\" data-end=\"1509\" class=\"\"\u003e\n\u003cp data-start=\"1466\" data-end=\"1509\" class=\"\"\u003e\u003cstrong data-start=\"1466\" data-end=\"1509\"\u003eCAT IV 600V Safety Rating \/ IEC 61010-1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1511\" data-end=\"1514\" class=\"\"\u003e\n\u003ch3 data-start=\"1516\" data-end=\"1533\" class=\"\"\u003e\u003cstrong data-start=\"1520\" data-end=\"1533\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1534\" data-end=\"1732\"\u003e\n\u003cli data-start=\"1534\" data-end=\"1583\" class=\"\"\u003e\n\u003cp data-start=\"1536\" data-end=\"1583\" class=\"\"\u003eElectrical utility and substation maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1584\" data-end=\"1623\" class=\"\"\u003e\n\u003cp data-start=\"1586\" data-end=\"1623\" class=\"\"\u003eTransformer and motor manufacturers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1624\" data-end=\"1683\" class=\"\"\u003e\n\u003cp data-start=\"1626\" data-end=\"1683\" class=\"\"\u003eIndustrial quality assurance and predictive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1684\" data-end=\"1732\" class=\"\"\u003e\n\u003cp data-start=\"1686\" data-end=\"1732\" class=\"\"\u003eHigh-voltage laboratories and diagnostic teams\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1734\" data-end=\"1737\" class=\"\"\u003e\n\u003ch3 data-start=\"1739\" data-end=\"1763\" class=\"\"\u003e\u003cstrong data-start=\"1743\" data-end=\"1763\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1764\" data-end=\"1947\"\u003e\n\u003cli data-start=\"1764\" data-end=\"1799\" class=\"\"\u003e\n\u003cp data-start=\"1766\" data-end=\"1799\" class=\"\"\u003eKyoritsu 3127 Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1800\" data-end=\"1847\" class=\"\"\u003e\n\u003cp data-start=\"1802\" data-end=\"1847\" class=\"\"\u003eHigh-voltage test leads and alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1848\" data-end=\"1874\" class=\"\"\u003e\n\u003cp data-start=\"1850\" data-end=\"1874\" class=\"\"\u003eUSB cable and software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1875\" data-end=\"1896\" class=\"\"\u003e\n\u003cp data-start=\"1877\" data-end=\"1896\" class=\"\"\u003eRugged carry case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1897\" data-end=\"1919\" class=\"\"\u003e\n\u003cp data-start=\"1899\" data-end=\"1919\" class=\"\"\u003eInstruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1920\" data-end=\"1947\" class=\"\"\u003e\n\u003cp data-start=\"1922\" data-end=\"1947\" class=\"\"\u003eBatteries (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1949\" data-end=\"1952\" class=\"\"\u003e\n\u003ch3 data-start=\"1954\" data-end=\"1981\" class=\"\"\u003e🔍 \u003cstrong data-start=\"1961\" data-end=\"1981\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1982\" data-end=\"2984\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1982\" data-end=\"2104\"\u003e\n\u003ctr data-start=\"1982\" data-end=\"2104\"\u003e\n\u003cth data-start=\"1982\" data-end=\"2016\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2016\" data-end=\"2043\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2018\" data-end=\"2035\"\u003eKyoritsu 3127\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2043\" data-end=\"2072\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2045\" data-end=\"2063\"\u003eMetrel MI 3205\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2072\" data-end=\"2104\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2074\" data-end=\"2088\"\u003eFluke 1555\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2232\" data-end=\"2984\"\u003e\n\u003ctr data-start=\"2232\" data-end=\"2358\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2267\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2267\" data-end=\"2296\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2296\" data-end=\"2326\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2326\" data-end=\"2358\"\u003e10,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2359\" data-end=\"2485\"\u003e\n\u003ctd data-start=\"2359\" data-end=\"2394\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2394\" data-end=\"2423\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2423\" data-end=\"2453\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2453\" data-end=\"2485\"\u003e2 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2486\" data-end=\"2609\"\u003e\n\u003ctd data-start=\"2486\" data-end=\"2521\" data-col-size=\"sm\"\u003ePI\/DAR Testing\u003c\/td\u003e\n\u003ctd data-start=\"2521\" data-end=\"2549\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2549\" data-end=\"2578\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2578\" data-end=\"2609\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2610\" data-end=\"2733\"\u003e\n\u003ctd data-start=\"2610\" data-end=\"2645\" data-col-size=\"sm\"\u003eData Logging \u0026amp; Export\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2645\" data-end=\"2673\"\u003e✅ USB + Memory\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2673\" data-end=\"2702\"\u003e✅ USB\/RS232 + Memory\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2702\" data-end=\"2733\"\u003e✅ USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2734\" data-end=\"2857\"\u003e\n\u003ctd data-start=\"2734\" data-end=\"2769\" data-col-size=\"sm\"\u003eGraphical Display\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2769\" data-end=\"2797\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2797\" data-end=\"2826\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2826\" data-end=\"2857\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2858\" data-end=\"2984\"\u003e\n\u003ctd data-start=\"2858\" data-end=\"2893\" data-col-size=\"sm\"\u003eBest Use\u003c\/td\u003e\n\u003ctd data-start=\"2893\" data-end=\"2922\" data-col-size=\"sm\"\u003eField + lab HV diagnostics\u003c\/td\u003e\n\u003ctd data-start=\"2922\" data-end=\"2952\" data-col-size=\"sm\"\u003eIndustrial \u0026amp; utility work\u003c\/td\u003e\n\u003ctd data-start=\"2952\" data-end=\"2984\" data-col-size=\"sm\"\u003eHV testing with Fluke tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kyoritsu","offers":[{"title":"Default Title","offer_id":6830828716076,"sku":"KEW3127","price":3745.87,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/kew3127-1.jpg?v=1536829397"},{"product_id":"copy-of-kyoritsu-3132a-1000v-analogue-insulation-tester","title":"KYORITSU 3132A 1000V Analogue Insulation Tester","description":"\u003cp\u003eTest insulation up to 100MΩ at 250V, 200MΩ at 500V, 400MΩ at 1000V and continuity up to 500Ω. Easy-to-read, illuminated analogue scale.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDust and drip proof construction. (designed to IEC 60529 IP54)\u003c\/li\u003e\n\u003cli\u003eDesigned to meet IEC 61010-1 and IEC 61557 safety standard.\u003c\/li\u003e\n\u003cli\u003e1mA rated test current at the minimum resistance.\u003c\/li\u003e\n\u003cli\u003e200mA measuring current on continuity testing.\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge of circuit capacitance. (Any charge stored in the circuit under test will be automatically discharged after testing.)\u003c\/li\u003e\n\u003cli\u003eLive circuit warning buzzer and neon lamp.\u003c\/li\u003e\n\u003cli\u003eSmall and lightweight. Shock resistant new case material.\u003c\/li\u003e\n\u003cli\u003eAC voltmeter with linear, easy-to-read scale.\u003c\/li\u003e\n\u003cli\u003eOperates on AA, R6 × 6 dry batteries.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1 year warranty. Serviced in Toronto\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eSpecifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"2\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e\u003cstrong data-spm-anchor-id=\"2114.10010108.1000023.i0.513b2d86EtdrZ8\"\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTest Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e250V\/500V\/1000V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eMeasuring Ranges \u003cbr\u003e(Mid-scale Value)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e100MΩ\/200MΩ\/400MΩ \u003cbr\u003e(1MΩ) (2MΩ) (4MΩ)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eOutput Voltage \u003cbr\u003eon open circuit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eRated test voltage+20%, -0%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eNominal Current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e1mA DC min.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eOutput Short\u003cbr\u003eCircuit Current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e1~2mA DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e0.1~10MΩ\/0.2~20MΩ\/0.4~40MΩ\u003cbr\u003e(Accuracy Guaranteed Ranges) ±5% of indicated value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e\u003cstrong\u003eContinuity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eMeasuring Ranges \u003cbr\u003e(Mid-scale Value)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e3Ω\/500Ω\u003cbr\u003e(1.5Ω) \/ (20Ω)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eOutput Voltage \u003cbr\u003eon open circuit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e4.1V DC approx.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eMeasuring Current\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e210mA DC min.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e|±1.5% of scale length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eAC Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e0~600V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e|±5% of scale length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eSafety Standard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eIEC 61010-1 CAT.III 600V Pollution Degree 2\u003cbr\u003eIEC 61010-2-031\u003cbr\u003eIEC 61557-1\/2\/4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eIEC 60529-IP54\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eEMC Standard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eIEC 61326-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eWithstand Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e3700V AC for 1 minute\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003ePower Source\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eR6P (AA) (1.5V) × 6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e106(L) × 160(W) × 72(D)mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e560g approx.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e(Test leads) Pouch for test leads\u003cbr\u003e8923 (F500mA\/600V fuse) × 2\u003cbr\u003eR6P (AA) × 6 \u003cbr\u003eShoulder Strap \u003cbr\u003eInstruction Manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eDownload\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/download\/dl\/496\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/download\/dl\/396\/\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCompare to\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.aliexpress.com\/item\/Kyoritsu-Insulation-continuity-Tester-Protected-Japan-3132A-KEW-NEW\/1886858167.html#!\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eKyoritsu Insulation continuity Tester Protected Japan 3132A KEW !!NEW!!\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Kyoritsu","offers":[{"title":"Default Title","offer_id":6910102241324,"sku":"KEW3132A","price":562.93,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/kyoritsu_3132A.jpg?v=1536829337"},{"product_id":"metrel-mi3205","title":"Metrel MI 3205 TeraOhmXA – 5kV Advanced High-Voltage Insulation Resistance Tester","description":"\u003cp data-start=\"272\" data-end=\"354\" class=\"\"\u003e\u003cstrong data-start=\"272\" data-end=\"354\"\u003eHigh-Accuracy 5kV Insulation Tester with 10 TΩ Range, PI\/DAR, and Data Logging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"356\" data-end=\"798\" class=\"\"\u003e\u003cstrong data-start=\"356\" data-end=\"377\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"377\" data-end=\"380\"\u003eThe \u003cstrong data-start=\"384\" data-end=\"412\"\u003eMetrel MI 3205 TeraOhmXA\u003c\/strong\u003e is a \u003cstrong data-start=\"418\" data-end=\"471\"\u003elaboratory-grade 5kV insulation resistance tester\u003c\/strong\u003e designed for \u003cstrong data-start=\"485\" data-end=\"544\"\u003ehigh-end industrial, utility, and research applications\u003c\/strong\u003e. It offers insulation resistance measurement up to \u003cstrong data-start=\"596\" data-end=\"605\"\u003e10 TΩ\u003c\/strong\u003e, supports \u003cstrong data-start=\"616\" data-end=\"664\"\u003eselectable test voltages from 50 V to 5000 V\u003c\/strong\u003e, and features a powerful suite of diagnostic functions such as \u003cstrong data-start=\"728\" data-end=\"755\"\u003ePI (Polarization Index)\u003c\/strong\u003e and \u003cstrong data-start=\"760\" data-end=\"797\"\u003eDAR (Dielectric Absorption Ratio)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"800\" data-end=\"1082\" class=\"\"\u003eThis advanced instrument is ideal for testing high-voltage motors, generators, transformers, cables, and switchgear. With \u003cstrong data-start=\"922\" data-end=\"953\"\u003ereal-time graphical display\u003c\/strong\u003e, \u003cstrong data-start=\"955\" data-end=\"974\"\u003ebuilt-in memory\u003c\/strong\u003e, and \u003cstrong data-start=\"980\" data-end=\"1009\"\u003eUSB\/RS232 PC connectivity\u003c\/strong\u003e, the MI 3205 delivers both portability and deep analytical capabilities.\u003c\/p\u003e\n\u003chr data-start=\"1084\" data-end=\"1087\" class=\"\"\u003e\n\u003ch3 data-start=\"1089\" data-end=\"1110\" class=\"\"\u003e\u003cstrong data-start=\"1093\" data-end=\"1110\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1111\" data-end=\"1594\"\u003e\n\u003cli data-start=\"1111\" data-end=\"1178\" class=\"\"\u003e\n\u003cp data-start=\"1113\" data-end=\"1178\" class=\"\"\u003e\u003cstrong data-start=\"1113\" data-end=\"1142\"\u003eAdjustable Test Voltages:\u003c\/strong\u003e 50 V to 5000 V in 10 V\/25 V steps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1179\" data-end=\"1239\" class=\"\"\u003e\n\u003cp data-start=\"1181\" data-end=\"1239\" class=\"\"\u003e\u003cstrong data-start=\"1181\" data-end=\"1213\"\u003eInsulation Resistance Range:\u003c\/strong\u003e Up to 10 TΩ (10,000 GΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1312\" class=\"\"\u003e\n\u003cp data-start=\"1242\" data-end=\"1312\" class=\"\"\u003e\u003cstrong data-start=\"1242\" data-end=\"1264\"\u003ePI and DAR Testing\u003c\/strong\u003e – For insulation aging and quality monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1313\" data-end=\"1353\" class=\"\"\u003e\n\u003cp data-start=\"1315\" data-end=\"1353\" class=\"\"\u003e\u003cstrong data-start=\"1315\" data-end=\"1351\"\u003eGraphical LCD with Trend Display\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1354\" data-end=\"1411\" class=\"\"\u003e\n\u003cp data-start=\"1356\" data-end=\"1411\" class=\"\"\u003e\u003cstrong data-start=\"1356\" data-end=\"1409\"\u003eBuilt-in Memory and USB\/RS232 Communication Ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1412\" data-end=\"1455\" class=\"\"\u003e\n\u003cp data-start=\"1414\" data-end=\"1455\" class=\"\"\u003e\u003cstrong data-start=\"1414\" data-end=\"1453\"\u003eRamp, Step Voltage, and Timer Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1456\" data-end=\"1503\" class=\"\"\u003e\n\u003cp data-start=\"1458\" data-end=\"1503\" class=\"\"\u003e\u003cstrong data-start=\"1458\" data-end=\"1501\"\u003eAutomatic Discharge of Capacitive Loads\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1504\" data-end=\"1557\" class=\"\"\u003e\n\u003cp data-start=\"1506\" data-end=\"1557\" class=\"\"\u003e\u003cstrong data-start=\"1506\" data-end=\"1555\"\u003eProtective Carrying Case for Rugged Field Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1558\" data-end=\"1594\" class=\"\"\u003e\n\u003cp data-start=\"1560\" data-end=\"1594\" class=\"\"\u003e\u003cstrong data-start=\"1560\" data-end=\"1594\"\u003eEN 61010-1, CAT IV 600 V Rated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1596\" data-end=\"1599\" class=\"\"\u003e\n\u003ch3 data-start=\"1601\" data-end=\"1618\" class=\"\"\u003e\u003cstrong data-start=\"1605\" data-end=\"1618\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1619\" data-end=\"1846\"\u003e\n\u003cli data-start=\"1619\" data-end=\"1677\" class=\"\"\u003e\n\u003cp data-start=\"1621\" data-end=\"1677\" class=\"\"\u003eElectrical utility substations and grid infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1678\" data-end=\"1734\" class=\"\"\u003e\n\u003cp data-start=\"1680\" data-end=\"1734\" class=\"\"\u003eTransformer and high-voltage equipment manufacturers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1735\" data-end=\"1795\" class=\"\"\u003e\n\u003cp data-start=\"1737\" data-end=\"1795\" class=\"\"\u003eCondition monitoring and predictive maintenance programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1796\" data-end=\"1846\" class=\"\"\u003e\n\u003cp data-start=\"1798\" data-end=\"1846\" class=\"\"\u003ePower plants and industrial quality control labs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1848\" data-end=\"1851\" class=\"\"\u003e\n\u003ch3 data-start=\"1853\" data-end=\"1877\" class=\"\"\u003e\u003cstrong data-start=\"1857\" data-end=\"1877\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1878\" data-end=\"2079\"\u003e\n\u003cli data-start=\"1878\" data-end=\"1906\" class=\"\"\u003e\n\u003cp data-start=\"1880\" data-end=\"1906\" class=\"\"\u003eMetrel MI 3205 TeraOhmXA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1907\" data-end=\"1954\" class=\"\"\u003e\n\u003cp data-start=\"1909\" data-end=\"1954\" class=\"\"\u003eHigh-voltage test leads and alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1955\" data-end=\"1979\" class=\"\"\u003e\n\u003cp data-start=\"1957\" data-end=\"1979\" class=\"\"\u003eUSB and RS232 cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1980\" data-end=\"2006\" class=\"\"\u003e\n\u003cp data-start=\"1982\" data-end=\"2006\" class=\"\"\u003ePC software and manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2007\" data-end=\"2029\" class=\"\"\u003e\n\u003cp data-start=\"2009\" data-end=\"2029\" class=\"\"\u003eHard carrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2030\" data-end=\"2057\" class=\"\"\u003e\n\u003cp data-start=\"2032\" data-end=\"2057\" class=\"\"\u003eCalibration certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2058\" data-end=\"2079\" class=\"\"\u003e\n\u003cp data-start=\"2060\" data-end=\"2079\" class=\"\"\u003eBatteries installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2081\" data-end=\"2084\" class=\"\"\u003e\n\u003ch3 data-start=\"2086\" data-end=\"2113\" class=\"\"\u003e🔍 \u003cstrong data-start=\"2093\" data-end=\"2113\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2114\" data-end=\"3100\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2114\" data-end=\"2234\"\u003e\n\u003ctr data-start=\"2114\" data-end=\"2234\"\u003e\n\u003cth data-start=\"2114\" data-end=\"2148\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2148\" data-end=\"2173\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2150\" data-end=\"2168\"\u003eMetrel MI 3205\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2173\" data-end=\"2202\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2175\" data-end=\"2193\"\u003eMetrel MI 3201\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2202\" data-end=\"2234\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2204\" data-end=\"2218\"\u003eFluke 1555\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2360\" data-end=\"3100\"\u003e\n\u003ctr data-start=\"2360\" data-end=\"2484\"\u003e\n\u003ctd data-start=\"2360\" data-end=\"2395\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2395\" data-end=\"2422\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2422\" data-end=\"2452\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2452\" data-end=\"2484\"\u003e10,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2485\" data-end=\"2609\"\u003e\n\u003ctd data-start=\"2485\" data-end=\"2520\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2520\" data-end=\"2547\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2547\" data-end=\"2577\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2577\" data-end=\"2609\"\u003e2 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2610\" data-end=\"2731\"\u003e\n\u003ctd data-start=\"2610\" data-end=\"2645\" data-col-size=\"sm\"\u003ePI\/DAR Capability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2645\" data-end=\"2671\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2671\" data-end=\"2700\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2700\" data-end=\"2731\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2732\" data-end=\"2853\"\u003e\n\u003ctd data-start=\"2732\" data-end=\"2767\" data-col-size=\"sm\"\u003eGraphical Display\u003c\/td\u003e\n\u003ctd data-start=\"2767\" data-end=\"2793\" data-col-size=\"sm\"\u003e✅ Yes (real-time)\u003c\/td\u003e\n\u003ctd data-start=\"2793\" data-end=\"2822\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2822\" data-end=\"2853\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2854\" data-end=\"2975\"\u003e\n\u003ctd data-start=\"2854\" data-end=\"2889\" data-col-size=\"sm\"\u003eData Export\u003c\/td\u003e\n\u003ctd data-start=\"2889\" data-end=\"2915\" data-col-size=\"sm\"\u003e✅ USB + RS232\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2915\" data-end=\"2944\"\u003e✅ USB\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2944\" data-end=\"2975\"\u003e✅ USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2976\" data-end=\"3100\"\u003e\n\u003ctd data-start=\"2976\" data-end=\"3011\" data-col-size=\"sm\"\u003eBest Use\u003c\/td\u003e\n\u003ctd data-start=\"3011\" data-end=\"3038\" data-col-size=\"sm\"\u003eLab + field diagnostics\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3038\" data-end=\"3068\"\u003eIndustrial diagnostics\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3068\" data-end=\"3100\"\u003eHV field testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Metrel","offers":[{"title":"Standard","offer_id":7195572830252,"sku":"MTMI3205 Standard","price":3304.48,"currency_code":"CAD","in_stock":true},{"title":"Canadian","offer_id":29506575499308,"sku":"MTMI3205 Canadian","price":3575.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/Untitled.jpg?v=1519265137"},{"product_id":"metrel-mi3210","title":"Metrel MI 3210 TeraOhm XA 10kV – High-Voltage Insulation Resistance Tester","description":"\u003cp class=\"\" data-end=\"397\" data-start=\"299\"\u003e\u003cstrong data-end=\"397\" data-start=\"299\"\u003eMetrel MI 3210 is no longer available. Recommended replacement: \u003ca href=\"https:\/\/duncaninstr.com\/products\/mi-3211\"\u003eMetrel MI 3211\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"397\" data-start=\"299\"\u003e\u003cstrong data-end=\"397\" data-start=\"299\"\u003eLaboratory-Grade 10kV Insulation Tester with 10 TΩ Range, PI\/DAR, USB, and Graphical Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"819\" data-start=\"399\"\u003e\u003cstrong data-end=\"420\" data-start=\"399\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-end=\"423\" data-start=\"420\"\u003eThe \u003cstrong data-end=\"461\" data-start=\"427\"\u003eMetrel MI 3210 TeraOhm XA 10kV\u003c\/strong\u003e is a \u003cstrong data-end=\"531\" data-start=\"467\"\u003eprofessional-grade high-voltage insulation resistance tester\u003c\/strong\u003e designed for demanding applications in \u003cstrong data-end=\"658\" data-start=\"571\"\u003eutilities, high-voltage labs, transformer manufacturing, and predictive maintenance\u003c\/strong\u003e. With test voltages up to 10,000 V and insulation resistance measurement up to \u003cstrong data-end=\"747\" data-start=\"738\"\u003e10 TΩ\u003c\/strong\u003e, this instrument delivers unmatched precision and advanced diagnostics.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1148\" data-start=\"821\"\u003eEquipped with \u003cstrong data-end=\"862\" data-start=\"835\"\u003ePI (Polarization Index)\u003c\/strong\u003e and \u003cstrong data-end=\"904\" data-start=\"867\"\u003eDAR (Dielectric Absorption Ratio)\u003c\/strong\u003e testing, a \u003cstrong data-end=\"947\" data-start=\"916\"\u003ereal-time graphical display\u003c\/strong\u003e, and \u003cstrong data-end=\"983\" data-start=\"953\"\u003eUSB\/RS232 PC communication\u003c\/strong\u003e, the MI 3210 provides comprehensive test results for critical insulation systems, including \u003cstrong data-end=\"1114\" data-start=\"1076\"\u003eramp testing, step voltage testing\u003c\/strong\u003e, and programmable test sequences.\u003c\/p\u003e\n\u003chr class=\"\" data-end=\"1153\" data-start=\"1150\"\u003e\n\u003ch3 class=\"\" data-end=\"1176\" data-start=\"1155\"\u003e\u003cstrong data-end=\"1176\" data-start=\"1159\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1683\" data-start=\"1177\"\u003e\n\u003cli class=\"\" data-end=\"1241\" data-start=\"1177\"\u003e\n\u003cp class=\"\" data-end=\"1241\" data-start=\"1179\"\u003e\u003cstrong data-end=\"1208\" data-start=\"1179\"\u003eAdjustable Test Voltages:\u003c\/strong\u003e 50 V to 10,000 V in 25 V steps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1308\" data-start=\"1242\"\u003e\n\u003cp class=\"\" data-end=\"1308\" data-start=\"1244\"\u003e\u003cstrong data-end=\"1282\" data-start=\"1244\"\u003eInsulation Resistance Measurement:\u003c\/strong\u003e Up to 10 TΩ (10,000 GΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1368\" data-start=\"1309\"\u003e\n\u003cp class=\"\" data-end=\"1368\" data-start=\"1311\"\u003e\u003cstrong data-end=\"1331\" data-start=\"1311\"\u003ePI \u0026amp; DAR Testing\u003c\/strong\u003e – For insulation quality over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1430\" data-start=\"1369\"\u003e\n\u003cp class=\"\" data-end=\"1430\" data-start=\"1371\"\u003e\u003cstrong data-end=\"1428\" data-start=\"1371\"\u003eReal-Time Graphical LCD Display with Trend Monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1479\" data-start=\"1431\"\u003e\n\u003cp class=\"\" data-end=\"1479\" data-start=\"1433\"\u003e\u003cstrong data-end=\"1477\" data-start=\"1433\"\u003eRamp, Step Voltage, and Timer Test Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1537\" data-start=\"1480\"\u003e\n\u003cp class=\"\" data-end=\"1537\" data-start=\"1482\"\u003e\u003cstrong data-end=\"1535\" data-start=\"1482\"\u003eAutomatic Discharge of Capacitive Load for Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1606\" data-start=\"1538\"\u003e\n\u003cp class=\"\" data-end=\"1606\" data-start=\"1540\"\u003e\u003cstrong data-end=\"1604\" data-start=\"1540\"\u003eUSB and RS232 Interfaces for PC Connectivity and Data Export\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1647\" data-start=\"1607\"\u003e\n\u003cp class=\"\" data-end=\"1647\" data-start=\"1609\"\u003e\u003cstrong data-end=\"1645\" data-start=\"1609\"\u003eInternal Memory for Test Storage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1683\" data-start=\"1648\"\u003e\n\u003cp class=\"\" data-end=\"1683\" data-start=\"1650\"\u003e\u003cstrong data-end=\"1683\" data-start=\"1650\"\u003eIEC 61010, CAT IV 600 V Rated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"\" data-end=\"1688\" data-start=\"1685\"\u003e\n\u003ch3 class=\"\" data-end=\"1707\" data-start=\"1690\"\u003e\u003cstrong data-end=\"1707\" data-start=\"1694\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1916\" data-start=\"1708\"\u003e\n\u003cli class=\"\" data-end=\"1744\" data-start=\"1708\"\u003e\n\u003cp class=\"\" data-end=\"1744\" data-start=\"1710\"\u003eHigh-voltage utility diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1782\" data-start=\"1745\"\u003e\n\u003cp class=\"\" data-end=\"1782\" data-start=\"1747\"\u003eTransformer and generator testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1819\" data-start=\"1783\"\u003e\n\u003cp class=\"\" data-end=\"1819\" data-start=\"1785\"\u003eCable and switchgear maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1868\" data-start=\"1820\"\u003e\n\u003cp class=\"\" data-end=\"1868\" data-start=\"1822\"\u003eLaboratory compliance and long-term analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1916\" data-start=\"1869\"\u003e\n\u003cp class=\"\" data-end=\"1916\" data-start=\"1871\"\u003ePredictive maintenance with detailed trending\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"\" data-end=\"1921\" data-start=\"1918\"\u003e\n\u003ch3 class=\"\" data-end=\"1947\" data-start=\"1923\"\u003e\u003cstrong data-end=\"1947\" data-start=\"1927\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2174\" data-start=\"1948\"\u003e\n\u003cli class=\"\" data-end=\"1984\" data-start=\"1948\"\u003e\n\u003cp class=\"\" data-end=\"1984\" data-start=\"1950\"\u003eMetrel MI 3210 Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2022\" data-start=\"1985\"\u003e\n\u003cp class=\"\" data-end=\"2022\" data-start=\"1987\"\u003eHigh-voltage test leads and clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2061\" data-start=\"2023\"\u003e\n\u003cp class=\"\" data-end=\"2061\" data-start=\"2025\"\u003eUSB and RS232 communication cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2097\" data-start=\"2062\"\u003e\n\u003cp class=\"\" data-end=\"2097\" data-start=\"2064\"\u003eMetrel software and user manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2122\" data-start=\"2098\"\u003e\n\u003cp class=\"\" data-end=\"2122\" data-start=\"2100\"\u003eRugged carrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2174\" data-start=\"2123\"\u003e\n\u003cp class=\"\" data-end=\"2174\" data-start=\"2125\"\u003eCalibration certificate and batteries (installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"\" data-end=\"2179\" data-start=\"2176\"\u003e\n\u003ch3 class=\"\" data-end=\"2208\" data-start=\"2181\"\u003e🔍 \u003cstrong data-end=\"2208\" data-start=\"2188\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"3219\" data-start=\"2209\"\u003e\n\u003cthead data-end=\"2332\" data-start=\"2209\"\u003e\n\u003ctr data-end=\"2332\" data-start=\"2209\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2243\" data-start=\"2209\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2270\" data-start=\"2243\"\u003e\u003cstrong data-end=\"2263\" data-start=\"2245\"\u003eMetrel MI 3210\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2300\" data-start=\"2270\"\u003e\u003cstrong data-end=\"2286\" data-start=\"2272\"\u003eFluke 1555\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2332\" data-start=\"2300\"\u003e\u003cstrong data-end=\"2322\" data-start=\"2302\"\u003eMegabras MI15KVE\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"3219\" data-start=\"2461\"\u003e\n\u003ctr data-end=\"2588\" data-start=\"2461\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2496\" data-start=\"2461\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2524\" data-start=\"2496\"\u003e10,000 V\u003c\/td\u003e\n\u003ctd data-end=\"2555\" data-start=\"2524\" data-col-size=\"sm\"\u003e10,000 V\u003c\/td\u003e\n\u003ctd data-end=\"2588\" data-start=\"2555\" data-col-size=\"sm\"\u003e15,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2716\" data-start=\"2589\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2624\" data-start=\"2589\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2652\" data-start=\"2624\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2683\" data-start=\"2652\"\u003e2 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2716\" data-start=\"2683\"\u003e1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2841\" data-start=\"2717\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2752\" data-start=\"2717\"\u003ePI\/DAR Capability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2779\" data-start=\"2752\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2809\" data-start=\"2779\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2841\" data-start=\"2809\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2966\" data-start=\"2842\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2877\" data-start=\"2842\"\u003eGraphical Display\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2904\" data-start=\"2877\"\u003e✅ Yes (real-time graph)\u003c\/td\u003e\n\u003ctd data-end=\"2934\" data-start=\"2904\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-end=\"2966\" data-start=\"2934\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3091\" data-start=\"2967\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3002\" data-start=\"2967\"\u003eUSB\/RS232 + Memory\u003c\/td\u003e\n\u003ctd data-end=\"3029\" data-start=\"3002\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-end=\"3059\" data-start=\"3029\" data-col-size=\"sm\"\u003e✅ USB only\u003c\/td\u003e\n\u003ctd data-end=\"3091\" data-start=\"3059\" data-col-size=\"sm\"\u003e✅ USB + RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3219\" data-start=\"3092\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3127\" data-start=\"3092\"\u003eBest Use\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3155\" data-start=\"3127\"\u003eLab + industrial field use\u003c\/td\u003e\n\u003ctd data-end=\"3186\" data-start=\"3155\" data-col-size=\"sm\"\u003eGeneral HV maintenance\u003c\/td\u003e\n\u003ctd data-end=\"3219\" data-start=\"3186\" data-col-size=\"sm\"\u003eUltra HV diagnostics (15kV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Metrel","offers":[{"title":"Default Title","offer_id":7211740921900,"sku":"MTMI3210","price":5200.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/Metrel-MI-3210.jpg?v=1519347304"},{"product_id":"megabras-mi20kve","title":"Megabras MI20KVE – 20kV High-Voltage Digital Insulation Resistance Tester","description":"\u003cp data-start=\"288\" data-end=\"389\" class=\"\"\u003e\u003cstrong data-start=\"288\" data-end=\"389\"\u003eExtreme High-Voltage Insulation Testing for Power Utilities, Labs, and HV Equipment Manufacturers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"391\" data-end=\"816\" class=\"\"\u003e\u003cstrong data-start=\"391\" data-end=\"412\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"412\" data-end=\"415\"\u003eThe \u003cstrong data-start=\"419\" data-end=\"439\"\u003eMegabras MI20KVE\u003c\/strong\u003e is an \u003cstrong data-start=\"446\" data-end=\"503\"\u003eindustrial-class 20,000V insulation resistance tester\u003c\/strong\u003e designed for the most demanding electrical testing environments. Ideal for \u003cstrong data-start=\"579\" data-end=\"640\"\u003epower utilities, HV equipment manufacturers, laboratories\u003c\/strong\u003e, and \u003cstrong data-start=\"646\" data-end=\"670\"\u003etransmission systems\u003c\/strong\u003e, it offers insulation resistance measurement up to \u003cstrong data-start=\"722\" data-end=\"732\"\u003e500 GΩ\u003c\/strong\u003e and a wide range of diagnostic features to ensure long-term reliability and safety.\u003c\/p\u003e\n\u003cp data-start=\"818\" data-end=\"1186\" class=\"\"\u003eWith \u003cstrong data-start=\"823\" data-end=\"874\"\u003eadjustable test voltages from 500 V to 20,000 V\u003c\/strong\u003e, \u003cstrong data-start=\"876\" data-end=\"895\"\u003ePI\/DAR analysis\u003c\/strong\u003e, and advanced testing modes like \u003cstrong data-start=\"929\" data-end=\"959\"\u003estep voltage, ramp testing\u003c\/strong\u003e, and \u003cstrong data-start=\"965\" data-end=\"986\"\u003etimed measurement\u003c\/strong\u003e, the MI20KVE provides both precision and flexibility. It also includes \u003cstrong data-start=\"1058\" data-end=\"1087\"\u003eUSB and RS232 data export\u003c\/strong\u003e, a \u003cstrong data-start=\"1091\" data-end=\"1120\"\u003egraphical backlit display\u003c\/strong\u003e, and \u003cstrong data-start=\"1126\" data-end=\"1159\"\u003eautomatic discharge functions\u003c\/strong\u003e to ensure operator safety.\u003c\/p\u003e\n\u003chr data-start=\"1188\" data-end=\"1191\" class=\"\"\u003e\n\u003ch3 data-start=\"1193\" data-end=\"1214\" class=\"\"\u003e\u003cstrong data-start=\"1197\" data-end=\"1214\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1215\" data-end=\"1748\"\u003e\n\u003cli data-start=\"1215\" data-end=\"1276\" class=\"\"\u003e\n\u003cp data-start=\"1217\" data-end=\"1276\" class=\"\"\u003e\u003cstrong data-start=\"1217\" data-end=\"1240\"\u003eTest Voltage Range:\u003c\/strong\u003e 500 V to 20,000 V (in 25 V steps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1277\" data-end=\"1332\" class=\"\"\u003e\n\u003cp data-start=\"1279\" data-end=\"1332\" class=\"\"\u003e\u003cstrong data-start=\"1279\" data-end=\"1317\"\u003eInsulation Resistance Measurement:\u003c\/strong\u003e Up to 500 GΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1333\" data-end=\"1410\" class=\"\"\u003e\n\u003cp data-start=\"1335\" data-end=\"1410\" class=\"\"\u003e\u003cstrong data-start=\"1335\" data-end=\"1400\"\u003ePI (Polarization Index) and DAR (Dielectric Absorption Ratio)\u003c\/strong\u003e testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1411\" data-end=\"1459\" class=\"\"\u003e\n\u003cp data-start=\"1413\" data-end=\"1459\" class=\"\"\u003e\u003cstrong data-start=\"1413\" data-end=\"1457\"\u003eStep Voltage, Ramp Test, and Timer Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1460\" data-end=\"1515\" class=\"\"\u003e\n\u003cp data-start=\"1462\" data-end=\"1515\" class=\"\"\u003e\u003cstrong data-start=\"1462\" data-end=\"1493\"\u003eReal-Time Graphical Display\u003c\/strong\u003e with trend plotting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1516\" data-end=\"1577\" class=\"\"\u003e\n\u003cp data-start=\"1518\" data-end=\"1577\" class=\"\"\u003e\u003cstrong data-start=\"1518\" data-end=\"1555\"\u003eUSB and RS232 Communication Ports\u003c\/strong\u003e for PC connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1578\" data-end=\"1638\" class=\"\"\u003e\n\u003cp data-start=\"1580\" data-end=\"1638\" class=\"\"\u003e\u003cstrong data-start=\"1580\" data-end=\"1636\"\u003eAutomatic Discharge and Test Inhibit Safety Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1639\" data-end=\"1690\" class=\"\"\u003e\n\u003cp data-start=\"1641\" data-end=\"1690\" class=\"\"\u003e\u003cstrong data-start=\"1641\" data-end=\"1688\"\u003eHeavy-Duty Field Housing with Carrying Case\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1691\" data-end=\"1748\" class=\"\"\u003e\n\u003cp data-start=\"1693\" data-end=\"1748\" class=\"\"\u003e\u003cstrong data-start=\"1693\" data-end=\"1748\"\u003eIEC 61010 CAT III 1000 V and IEEE 43-2000 Compliant\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1750\" data-end=\"1753\" class=\"\"\u003e\n\u003ch3 data-start=\"1755\" data-end=\"1772\" class=\"\"\u003e\u003cstrong data-start=\"1759\" data-end=\"1772\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1773\" data-end=\"2001\"\u003e\n\u003cli data-start=\"1773\" data-end=\"1814\" class=\"\"\u003e\n\u003cp data-start=\"1775\" data-end=\"1814\" class=\"\"\u003ePower transmission system diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1815\" data-end=\"1850\" class=\"\"\u003e\n\u003cp data-start=\"1817\" data-end=\"1850\" class=\"\"\u003eHigh-voltage laboratory testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1851\" data-end=\"1891\" class=\"\"\u003e\n\u003cp data-start=\"1853\" data-end=\"1891\" class=\"\"\u003eGenerator and transformer QA testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1892\" data-end=\"1944\" class=\"\"\u003e\n\u003cp data-start=\"1894\" data-end=\"1944\" class=\"\"\u003ePredictive maintenance in substations and plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1945\" data-end=\"2001\" class=\"\"\u003e\n\u003cp data-start=\"1947\" data-end=\"2001\" class=\"\"\u003eUltra-high-voltage cable testing and insulation audits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2003\" data-end=\"2006\" class=\"\"\u003e\n\u003ch3 data-start=\"2008\" data-end=\"2032\" class=\"\"\u003e\u003cstrong data-start=\"2012\" data-end=\"2032\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2033\" data-end=\"2255\"\u003e\n\u003cli data-start=\"2033\" data-end=\"2071\" class=\"\"\u003e\n\u003cp data-start=\"2035\" data-end=\"2071\" class=\"\"\u003eMegabras MI20KVE Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2072\" data-end=\"2128\" class=\"\"\u003e\n\u003cp data-start=\"2074\" data-end=\"2128\" class=\"\"\u003eHigh-voltage shielded test leads and alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2129\" data-end=\"2153\" class=\"\"\u003e\n\u003cp data-start=\"2131\" data-end=\"2153\" class=\"\"\u003eUSB and RS232 cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2154\" data-end=\"2182\" class=\"\"\u003e\n\u003cp data-start=\"2156\" data-end=\"2182\" class=\"\"\u003eData management software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2183\" data-end=\"2204\" class=\"\"\u003e\n\u003cp data-start=\"2185\" data-end=\"2204\" class=\"\"\u003eRugged carry case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2205\" data-end=\"2255\" class=\"\"\u003e\n\u003cp data-start=\"2207\" data-end=\"2255\" class=\"\"\u003eInstruction manual and calibration certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2257\" data-end=\"2260\" class=\"\"\u003e\n\u003ch3 data-start=\"2262\" data-end=\"2289\" class=\"\"\u003e🔍 \u003cstrong data-start=\"2269\" data-end=\"2289\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2290\" data-end=\"3306\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2290\" data-end=\"2412\"\u003e\n\u003ctr data-start=\"2290\" data-end=\"2412\"\u003e\n\u003cth data-start=\"2290\" data-end=\"2324\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2324\" data-end=\"2350\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2326\" data-end=\"2346\"\u003eMegabras MI20KVE\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2350\" data-end=\"2380\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2352\" data-end=\"2370\"\u003eMetrel MI 3210\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2380\" data-end=\"2412\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2382\" data-end=\"2402\"\u003eMegabras MI15KVE\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2542\" data-end=\"3306\"\u003e\n\u003ctr data-start=\"2542\" data-end=\"2670\"\u003e\n\u003ctd data-start=\"2542\" data-end=\"2577\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2577\" data-end=\"2605\" data-col-size=\"sm\"\u003e20,000 V\u003c\/td\u003e\n\u003ctd data-start=\"2605\" data-end=\"2637\" data-col-size=\"sm\"\u003e10,000 V\u003c\/td\u003e\n\u003ctd data-start=\"2637\" data-end=\"2670\" data-col-size=\"sm\"\u003e15,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2671\" data-end=\"2799\"\u003e\n\u003ctd data-start=\"2671\" data-end=\"2706\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-start=\"2706\" data-end=\"2734\" data-col-size=\"sm\"\u003e500 GΩ\u003c\/td\u003e\n\u003ctd data-start=\"2734\" data-end=\"2766\" data-col-size=\"sm\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-start=\"2766\" data-end=\"2799\" data-col-size=\"sm\"\u003e1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2800\" data-end=\"2925\"\u003e\n\u003ctd data-start=\"2800\" data-end=\"2835\" data-col-size=\"sm\"\u003ePI\/DAR Capability\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2835\" data-end=\"2862\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2862\" data-end=\"2893\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2893\" data-end=\"2925\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2926\" data-end=\"3051\"\u003e\n\u003ctd data-start=\"2926\" data-end=\"2961\" data-col-size=\"sm\"\u003eGraphical Display\u003c\/td\u003e\n\u003ctd data-start=\"2961\" data-end=\"2988\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2988\" data-end=\"3019\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3019\" data-end=\"3051\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3052\" data-end=\"3177\"\u003e\n\u003ctd data-start=\"3052\" data-end=\"3087\" data-col-size=\"sm\"\u003eUSB\/RS232 Output\u003c\/td\u003e\n\u003ctd data-start=\"3087\" data-end=\"3114\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3114\" data-end=\"3145\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3145\" data-end=\"3177\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3178\" data-end=\"3306\"\u003e\n\u003ctd data-start=\"3178\" data-end=\"3213\" data-col-size=\"sm\"\u003eBest Use\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3213\" data-end=\"3241\"\u003eUltra HV lab\/utility\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3241\" data-end=\"3273\"\u003eHV field + lab diagnostics\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3273\" data-end=\"3306\"\u003eHV production testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MEGABRAS","offers":[{"title":"Default Title","offer_id":8470899687468,"sku":"MGMI20KV","price":4800.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/Mi20KVe.PNG?v=1523125043"},{"product_id":"metrel-md-9070-insulation-continuity-digital-multimeter","title":"Metrel MD 9070 Insulation \u0026 Continuity Digital Multimeter","description":"\u003cp class=\"\" data-end=\"278\" data-start=\"208\"\u003e\u003cstrong data-end=\"278\" data-start=\"208\"\u003eAdd to Cart – Start Testing Smarter Today\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-end=\"278\" data-start=\"208\"\u003e\u003cstrong data-end=\"278\" data-start=\"208\"\u003eAdvanced True RMS Multimeter for Industrial and Electrical Testing\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"\" data-end=\"678\" data-start=\"280\"\u003e\u003cstrong data-end=\"301\" data-start=\"280\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-end=\"304\" data-start=\"301\"\u003eThe \u003cstrong data-end=\"326\" data-start=\"308\"\u003eMetrel MD 9070\u003c\/strong\u003e is a high-performance \u003cstrong data-end=\"397\" data-start=\"349\"\u003einsulation and continuity digital multimeter\u003c\/strong\u003e designed for demanding industrial, electrical, and HVAC applications. Featuring \u003cstrong data-end=\"503\" data-start=\"478\"\u003eTrue RMS measurements\u003c\/strong\u003e, \u003cstrong data-end=\"534\" data-start=\"505\"\u003eCAT IV 600V safety rating\u003c\/strong\u003e, and an integrated \u003cstrong data-end=\"598\" data-start=\"554\"\u003einsulation resistance tester up to 1000V\u003c\/strong\u003e, this meter ensures accurate diagnostics and reliable performance in the field.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"866\" data-start=\"680\"\u003eWhether you're troubleshooting industrial control panels, verifying motor windings, or conducting safety inspections, the MD 9070 provides the accuracy and durability professionals need.\u003c\/p\u003e\n\u003chr class=\"\" data-end=\"871\" data-start=\"868\"\u003e\n\u003ch3 class=\"\" data-end=\"894\" data-start=\"873\"\u003e\u003cstrong data-end=\"894\" data-start=\"877\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1487\" data-start=\"895\"\u003e\n\u003cli class=\"\" data-end=\"976\" data-start=\"895\"\u003e\n\u003cp class=\"\" data-end=\"976\" data-start=\"897\"\u003e\u003cstrong data-end=\"933\" data-start=\"897\"\u003eTrue RMS AC\/DC Voltage \u0026amp; Current\u003c\/strong\u003e: Accurate readings in complex environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1056\" data-start=\"977\"\u003e\n\u003cp class=\"\" data-end=\"1056\" data-start=\"979\"\u003e\u003cstrong data-end=\"1012\" data-start=\"979\"\u003eInsulation Resistance Testing\u003c\/strong\u003e: Up to 1000 V for high-voltage applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1117\" data-start=\"1057\"\u003e\n\u003cp class=\"\" data-end=\"1117\" data-start=\"1059\"\u003e\u003cstrong data-end=\"1093\" data-start=\"1059\"\u003eContinuity Testing with Buzzer\u003c\/strong\u003e: Fast, audible feedback\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1194\" data-start=\"1118\"\u003e\n\u003cp class=\"\" data-end=\"1194\" data-start=\"1120\"\u003e\u003cstrong data-end=\"1155\" data-start=\"1120\"\u003eLow-Resistance Measurement Mode\u003c\/strong\u003e: Ideal for checking ground connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1258\" data-start=\"1195\"\u003e\n\u003cp class=\"\" data-end=\"1258\" data-start=\"1197\"\u003e\u003cstrong data-end=\"1226\" data-start=\"1197\"\u003eLarge Backlit LCD Display\u003c\/strong\u003e: Clear readings in any lighting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1343\" data-start=\"1259\"\u003e\n\u003cp class=\"\" data-end=\"1343\" data-start=\"1261\"\u003e\u003cstrong data-end=\"1300\" data-start=\"1261\"\u003eCAT IV 600 V \/ CAT III 1000 V Rated\u003c\/strong\u003e: Maximum safety in industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1419\" data-start=\"1344\"\u003e\n\u003cp class=\"\" data-end=\"1419\" data-start=\"1346\"\u003e\u003cstrong data-end=\"1388\" data-start=\"1346\"\u003eData Hold, Min\/Max, and Auto Power Off\u003c\/strong\u003e: Useful features for fieldwork\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1487\" data-start=\"1420\"\u003e\n\u003cp class=\"\" data-end=\"1487\" data-start=\"1422\"\u003e\u003cstrong data-end=\"1441\" data-start=\"1422\"\u003eDurable Housing\u003c\/strong\u003e: Built to withstand tough job site conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"\" data-end=\"1492\" data-start=\"1489\"\u003e\n\u003ch3 class=\"\" data-end=\"1512\" data-start=\"1494\"\u003e\u003cstrong data-end=\"1512\" data-start=\"1498\"\u003eIdeal For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1679\" data-start=\"1513\"\u003e\n\u003cli class=\"\" data-end=\"1567\" data-start=\"1513\"\u003e\n\u003cp class=\"\" data-end=\"1567\" data-start=\"1515\"\u003eElectrical contractors and maintenance technicians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1602\" data-start=\"1568\"\u003e\n\u003cp class=\"\" data-end=\"1602\" data-start=\"1570\"\u003eIndustrial equipment servicing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1630\" data-start=\"1603\"\u003e\n\u003cp class=\"\" data-end=\"1630\" data-start=\"1605\"\u003ePanel builders and OEMs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1679\" data-start=\"1631\"\u003e\n\u003cp class=\"\" data-end=\"1679\" data-start=\"1633\"\u003eUtility and power distribution professionals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\" class=\"\" data-end=\"1679\" data-start=\"1631\"\u003e\u003cstrong\u003eOrder Today! Make Your Job Easier and Safer!\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"\" data-end=\"1684\" data-start=\"1681\"\u003e\n\u003ch3 class=\"\" data-end=\"1712\" data-start=\"1686\"\u003e\u003cstrong data-end=\"1712\" data-start=\"1690\"\u003eWhat's in the Box:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1831\" data-start=\"1713\"\u003e\n\u003cli class=\"\" data-end=\"1750\" data-start=\"1713\"\u003e\n\u003cp class=\"\" data-end=\"1750\" data-start=\"1715\"\u003eMetrel MD 9070 Digital Multimeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1765\" data-start=\"1751\"\u003e\n\u003cp class=\"\" data-end=\"1765\" data-start=\"1753\"\u003eTest leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1795\" data-start=\"1766\"\u003e\n\u003cp class=\"\" data-end=\"1795\" data-start=\"1768\"\u003eBatteries (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1811\" data-start=\"1796\"\u003e\n\u003cp class=\"\" data-end=\"1811\" data-start=\"1798\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1831\" data-start=\"1812\"\u003e\n\u003cp class=\"\" data-end=\"1831\" data-start=\"1814\"\u003eSoft carry case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"\" data-end=\"1836\" data-start=\"1833\"\u003e\n\u003ch3 class=\"\" data-end=\"1861\" data-start=\"1838\"\u003e\u003cstrong data-end=\"1861\" data-start=\"1842\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2093\" data-start=\"1862\"\u003e\n\u003cli class=\"\" data-end=\"1903\" data-start=\"1862\"\u003e\n\u003cp class=\"\" data-end=\"1903\" data-start=\"1864\"\u003e\u003cstrong data-end=\"1882\" data-start=\"1864\"\u003eVoltage Range:\u003c\/strong\u003e Up to 1000 V AC\/DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1943\" data-start=\"1904\"\u003e\n\u003cp class=\"\" data-end=\"1943\" data-start=\"1906\"\u003e\u003cstrong data-end=\"1924\" data-start=\"1906\"\u003eCurrent Range:\u003c\/strong\u003e Up to 10 A AC\/DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1985\" data-start=\"1944\"\u003e\n\u003cp class=\"\" data-end=\"1985\" data-start=\"1946\"\u003e\u003cstrong data-end=\"1972\" data-start=\"1946\"\u003eInsulation Resistance:\u003c\/strong\u003e Up to 2 GΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2023\" data-start=\"1986\"\u003e\n\u003cp class=\"\" data-end=\"2023\" data-start=\"1988\"\u003e\u003cstrong data-end=\"2003\" data-start=\"1988\"\u003eContinuity:\u003c\/strong\u003e \u0026lt;30 Ω with buzzer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2051\" data-start=\"2024\"\u003e\n\u003cp class=\"\" data-end=\"2051\" data-start=\"2026\"\u003e\u003cstrong data-end=\"2044\" data-start=\"2026\"\u003eDisplay Count:\u003c\/strong\u003e 6000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2093\" data-start=\"2052\"\u003e\n\u003cp class=\"\" data-end=\"2093\" data-start=\"2054\"\u003e\u003cstrong data-end=\"2065\" data-start=\"2054\"\u003eSafety:\u003c\/strong\u003e IEC\/EN 61010, CAT IV 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"265\" data-start=\"193\"\u003e✅ \u003cstrong data-end=\"265\" data-start=\"199\"\u003eFeature Comparison: Metrel MD 9070 vs Fluke 1503 vs Fluke 1507\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2787\" data-start=\"267\"\u003e\n\u003cthead data-end=\"445\" data-start=\"267\"\u003e\n\u003ctr data-end=\"445\" data-start=\"267\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"302\" data-start=\"267\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"352\" data-start=\"302\"\u003e\u003cstrong data-end=\"322\" data-start=\"304\"\u003eMetrel MD 9070\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"398\" data-start=\"352\"\u003e\u003cstrong data-end=\"368\" data-start=\"354\"\u003eFluke 1503\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"445\" data-start=\"398\"\u003e\u003cstrong data-end=\"414\" data-start=\"400\"\u003eFluke 1507\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2787\" data-start=\"625\"\u003e\n\u003ctr data-end=\"804\" data-start=\"625\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"660\" data-start=\"625\"\u003e\u003cstrong data-end=\"655\" data-start=\"627\"\u003eInsulation Test Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"710\" data-start=\"660\" data-col-size=\"md\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003ctd data-end=\"757\" data-start=\"710\" data-col-size=\"sm\"\u003e500 V, 1000 V\u003c\/td\u003e\n\u003ctd data-end=\"804\" data-start=\"757\" data-col-size=\"sm\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"985\" data-start=\"805\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"840\" data-start=\"805\"\u003e\u003cstrong data-end=\"838\" data-start=\"807\"\u003eInsulation Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"890\" data-start=\"840\"\u003eUp to 2 GΩ\u003c\/td\u003e\n\u003ctd data-end=\"937\" data-start=\"890\" data-col-size=\"sm\"\u003eUp to 2 GΩ\u003c\/td\u003e\n\u003ctd data-end=\"985\" data-start=\"937\" data-col-size=\"sm\"\u003eUp to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1166\" data-start=\"986\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1021\" data-start=\"986\"\u003e\u003cstrong data-end=\"1010\" data-start=\"988\"\u003eContinuity Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1071\" data-start=\"1021\" data-col-size=\"md\"\u003eYes, with buzzer\u003c\/td\u003e\n\u003ctd data-end=\"1118\" data-start=\"1071\" data-col-size=\"sm\"\u003eYes, with buzzer\u003c\/td\u003e\n\u003ctd data-end=\"1166\" data-start=\"1118\" data-col-size=\"sm\"\u003eYes, with buzzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1344\" data-start=\"1167\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1202\" data-start=\"1167\"\u003e\u003cstrong data-end=\"1202\" data-start=\"1169\"\u003eTrue RMS Multimeter Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1251\" data-start=\"1202\"\u003e✅ Fully featured multimeter (V, A, Ohms, etc.)\u003c\/td\u003e\n\u003ctd data-end=\"1297\" data-start=\"1251\" data-col-size=\"sm\"\u003e❌ Insulation tester only\u003c\/td\u003e\n\u003ctd data-end=\"1344\" data-start=\"1297\" data-col-size=\"sm\"\u003e❌ Insulation tester only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1525\" data-start=\"1345\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1380\" data-start=\"1345\"\u003e\u003cstrong data-end=\"1370\" data-start=\"1347\"\u003eVoltage Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1430\" data-start=\"1380\" data-col-size=\"md\"\u003eUp to 1000 V AC\/DC\u003c\/td\u003e\n\u003ctd data-end=\"1477\" data-start=\"1430\" data-col-size=\"sm\"\u003eUp to 600 V AC\/DC\u003c\/td\u003e\n\u003ctd data-end=\"1525\" data-start=\"1477\" data-col-size=\"sm\"\u003eUp to 600 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1706\" data-start=\"1526\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1561\" data-start=\"1526\"\u003e\u003cstrong data-end=\"1551\" data-start=\"1528\"\u003eCurrent Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1611\" data-start=\"1561\"\u003eUp to 10 A AC\/DC\u003c\/td\u003e\n\u003ctd data-end=\"1658\" data-start=\"1611\" data-col-size=\"sm\"\u003e❌ No current measurement\u003c\/td\u003e\n\u003ctd data-end=\"1706\" data-start=\"1658\" data-col-size=\"sm\"\u003e❌ No current measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1887\" data-start=\"1707\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1742\" data-start=\"1707\"\u003e\u003cstrong data-end=\"1735\" data-start=\"1709\"\u003eResistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1792\" data-start=\"1742\" data-col-size=\"md\"\u003eYes (including low-ohm continuity mode)\u003c\/td\u003e\n\u003ctd data-end=\"1839\" data-start=\"1792\" data-col-size=\"sm\"\u003eYes (basic)\u003c\/td\u003e\n\u003ctd data-end=\"1887\" data-start=\"1839\" data-col-size=\"sm\"\u003eYes (basic + PI\/DAR capability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2067\" data-start=\"1888\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1923\" data-start=\"1888\"\u003e\u003cstrong data-end=\"1908\" data-start=\"1890\"\u003ePI\/DAR Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"1973\" data-start=\"1923\" data-col-size=\"md\"\u003e❌ Not available\u003c\/td\u003e\n\u003ctd data-end=\"2020\" data-start=\"1973\" data-col-size=\"sm\"\u003e❌ Not available\u003c\/td\u003e\n\u003ctd data-end=\"2067\" data-start=\"2020\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2245\" data-start=\"2068\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2103\" data-start=\"2068\"\u003e\u003cstrong data-end=\"2089\" data-start=\"2070\"\u003eBacklit Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2152\" data-start=\"2103\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-end=\"2198\" data-start=\"2152\" data-col-size=\"sm\"\u003e❌ No\u003c\/td\u003e\n\u003ctd data-end=\"2245\" data-start=\"2198\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2425\" data-start=\"2246\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2281\" data-start=\"2246\"\u003e\u003cstrong data-end=\"2265\" data-start=\"2248\"\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2331\" data-start=\"2281\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003ctd data-end=\"2378\" data-start=\"2331\" data-col-size=\"sm\"\u003eCAT III 600 V\u003c\/td\u003e\n\u003ctd data-end=\"2425\" data-start=\"2378\" data-col-size=\"sm\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2606\" data-start=\"2426\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2461\" data-start=\"2426\"\u003e\u003cstrong data-end=\"2443\" data-start=\"2428\"\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2511\" data-start=\"2461\" data-col-size=\"md\"\u003eMultimeter-style handheld\u003c\/td\u003e\n\u003ctd data-end=\"2558\" data-start=\"2511\" data-col-size=\"sm\"\u003eDedicated insulation tester\u003c\/td\u003e\n\u003ctd data-end=\"2606\" data-start=\"2558\" data-col-size=\"sm\"\u003eDedicated insulation tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2787\" data-start=\"2607\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2642\" data-start=\"2607\"\u003e\u003cstrong data-end=\"2621\" data-start=\"2609\"\u003eBest For\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2692\" data-start=\"2642\" data-col-size=\"md\"\u003eGeneral electrical + insulation testing\u003c\/td\u003e\n\u003ctd data-end=\"2739\" data-start=\"2692\" data-col-size=\"sm\"\u003eBasic insulation testing\u003c\/td\u003e\n\u003ctd data-end=\"2787\" data-start=\"2739\" data-col-size=\"sm\"\u003eAdvanced insulation diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Metrel","offers":[{"title":"Default Title","offer_id":11842744254508,"sku":"MTMD9070","price":654.5,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/MD_9070.PNG?v=1536934351"},{"product_id":"metrel-mi-3121-insulation-continuity-tester","title":"METREL MI 3121 Insulation Continuity Tester","description":"\u003cp\u003e\u003cspan\u003eThe MI 3121 SMARTEC Insulation \/ Continuity is a tester for testing of electrical installations. With both an analogue and digital representation of the results, the instrument ensures accurate measurements up to 2000 Ω on continuity and up to 30 GΩ on insulation function. Configurable limits enable a PASS \/ FAIL evaluation of test results, which is accompanied with the bright red and green indicator lights for comfortable use even in the dark conditions. The MI 3121 is equipped with a built-in charger and has a magnetic holder in order to free up hands for testing. All the results can be quickly saved on the instrument and then downloaded via the optional A 1291 EuroLink PRO or A 1290 EuroLink PRO Plus software for evaluation and professional report generation after testing. The MI 3121 SMARTEC Insulation \/ Continuity performs continuity, insulation AC voltage and frequency measurement tests.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eMeasuring functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation resistance with DC voltage;\u003c\/li\u003e\n\u003cli\u003eContinuity of PE conductors with 200 mA test current with polarity change;\u003c\/li\u003e\n\u003cli\u003eContinuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping;\u003c\/li\u003e\n\u003cli\u003eTRMS voltage and frequency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation range: wide range of insulation test voltages from 50 V to 1000 V, measuring range up to 30 GΩ.\u003c\/li\u003e\n\u003cli\u003eAnalogue scale and digital LCD: measuring results are displayed both in numeric and analogue representation.\u003c\/li\u003e\n\u003cli\u003eDownloadable: downloads via RS232 or USB cable directly to the PC with the help of the optional software.\u003c\/li\u003e\n\u003cli\u003eUpgradeable: if changes occur to the regulations upgrades can be made to the firmware to keep the instrument up to date.\u003c\/li\u003e\n\u003cli\u003ePolarity swap: automatic polarity reversal on continuity test.\u003c\/li\u003e\n\u003cli\u003eBuilt-in charger \u0026amp; rechargeable batteries: instrument has a built-in charging circuit and comes complete with a set of rechargeable NiMH batteries.  \u003c\/li\u003e\n\u003cli\u003eCustom limits: if limits are set on insulation or continuity function then large green and red lights of the LEDs will indicate a PASS or FAIL evaluation of test result.\u003c\/li\u003e\n\u003cli\u003eEasy to use: large bright LCD display and large buttons enable easy handling of the instrument (even while wearing gloves).\u003c\/li\u003e\n\u003cli\u003eMagnetic holder: magnet for fixing instrument on metal surfaces enables hands-free operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownload:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/Single_2008_MI_3121_Insulation_Continuity_Ang.pdf?6019252693861863541\"\u003eFull specification\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Metrel","offers":[{"title":"Default Title","offer_id":13524015743020,"sku":"MTMI3121","price":792.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/mi-3121-merac-izolacnych-odporov.jpg?v=1548448748"},{"product_id":"kyoritsu-3551-1000v-digital-insulation-continuity-testers","title":"KYORITSU 3551 1000V Digital Insulation \/ Continuity Tester","description":"\u003cul\u003e\n\u003cli\u003eWorld’s fastest measurement speed (0.5 sec.)\u003c\/li\u003e\n\u003cli\u003eSix ranges available for insulation\u003c\/li\u003e\n\u003cli\u003eResistance test (50\/100\/125\/250\/500\/1000 V) up to 40 GOhm\u003c\/li\u003e\n\u003cli\u003eDiagnostic Insulation Test : PI, DAR\u003c\/li\u003e\n\u003cli\u003eAC\/DC Voltage Measurement\u003c\/li\u003e\n\u003cli\u003eContinuity Test @200mA\u003c\/li\u003e\n\u003cli\u003eLCD backlight and LED spot light facilitate working at dimly illuminated location or at nighttime work. The built-in illuminance sensor automatically turns on\/off the lights.\u003c\/li\u003e\n\u003cli\u003eTest probe comes with remote control switch (supplied)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_backlight_large.png?v=1549479460\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_Auto_Power_Off_large.png?v=1549479497\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_50v_large.png?v=1549479525\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_100v_49d9f1f6-2f62-4095-b592-dcb5a761dd8f_large.png?v=1549479583\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_125v_large.png?v=1549479551\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_250v_large.png?v=1549479556\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_500v_large.png?v=1549479562\" alt=\"\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_1000v_large.png?v=1549479797\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_acdcv_large.png?v=1549479831\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_ohm_large.png?v=1549479847\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eKEW3551 : Standard model\u003cbr\u003eKEW3552 : With memory function\u003cbr\u003eKEW3552BT : With memory and Bluetooth communication functions\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eThe right model for your application\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0185%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e6 ranges insulation resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003ePC comm.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0185%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eKEW 3551\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%; text-align: left;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 24.0185%;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eKEW 3552\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 24.0185%;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e KEW3553BT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eIncluded Accessories:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 99.8162%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e 7260（Test leads with remote control switch）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_7260_large.png?v=1549480880\" alt=\"\" width=\"100\" height=\"140\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e7261A（Test leads with alligator clip）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_7261_large.png?v=1549480920\" alt=\"\" width=\"120\" height=\"126\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e8017A（Extension prod long）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_8017A_large.png?v=1549480952\" alt=\"\" width=\"95\" height=\"113\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e9173（Carrying case）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_9173_large.png?v=1549480978\" alt=\"\" width=\"117\" height=\"103\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e9121（Shoulder strap）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_9121_large.png?v=1549480996\" alt=\"\" width=\"88\" height=\"118\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003eLR6（AA）（1.5V）x4\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003eInstruction manual\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDownload\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/3551_3552_3552BT_1E_L.pdf?12375626206283735792\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/3551_3552_3552BT_IM_92-2339_E_L.pdf?11265191022118200594\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Kyoritsu","offers":[{"title":"Default Title","offer_id":13702741786668,"sku":"KEW3551","price":801.79,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/KEW3551.png?v=1549478403"},{"product_id":"kyoritsu-3552-1000v-digital-insulation-continuity-testers","title":"KYORITSU 3552 1000V Digital Insulation \/ Continuity Tester with Memory Function","description":"\u003cul\u003e\n\u003cli\u003eWorld’s fastest measurement speed (0.5 sec.)\u003c\/li\u003e\n\u003cli\u003eSix ranges available for insulation\u003c\/li\u003e\n\u003cli\u003eResistance test (50\/100\/125\/250\/500\/1000 V) up to 40 GOhm\u003c\/li\u003e\n\u003cli\u003eDiagnostic Insulation Test : PI, DAR\u003c\/li\u003e\n\u003cli\u003eAC\/DC Voltage Measurement\u003c\/li\u003e\n\u003cli\u003eContinuity Test @200mA\u003c\/li\u003e\n\u003cli\u003eLCD backlight and LED spot light facilitate working at dimly illuminated location or at nighttime work. The built-in illuminance sensor automatically turns on\/off the lights.\u003c\/li\u003e\n\u003cli\u003eTest probe comes with remote control switch (supplied)\u003c\/li\u003e\n\u003cli\u003eMemory function - can save 1000 results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_backlight_large.png?v=1549479460\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_Auto_Power_Off_large.png?v=1549479497\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_50v_large.png?v=1549479525\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_100v_49d9f1f6-2f62-4095-b592-dcb5a761dd8f_large.png?v=1549479583\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_125v_large.png?v=1549479551\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_250v_large.png?v=1549479556\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_500v_large.png?v=1549479562\" alt=\"\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_1000v_large.png?v=1549479797\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_acdcv_large.png?v=1549479831\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_ohm_large.png?v=1549479847\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_usb_large.png?v=1549553656\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eKEW3551 : Standard model\u003cbr\u003eKEW3552 : With memory function\u003cbr\u003eKEW3552BT : With memory and Bluetooth communication functions\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eThe right model for your application\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0185%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e6 ranges insulation resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003ePC comm.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0185%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eKEW 3551\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%; text-align: left;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 24.0185%;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eKEW 3552\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 24.0185%;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e KEW3553BT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eIncluded Accessories:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 99.8162%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e 7260（Test leads with remote control switch）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_7260_large.png?v=1549480880\" alt=\"\" width=\"100\" height=\"140\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e7261A（Test leads with alligator clip）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_7261_large.png?v=1549480920\" alt=\"\" width=\"120\" height=\"126\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e8017A（Extension prod long）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_8017A_large.png?v=1549480952\" alt=\"\" width=\"95\" height=\"113\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e9173（Carrying case）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_9173_large.png?v=1549480978\" alt=\"\" width=\"117\" height=\"103\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e9121（Shoulder strap）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_9121_large.png?v=1549480996\" alt=\"\" width=\"88\" height=\"118\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003eLR6（AA）（1.5V）x4\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003eInstruction manual\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOptional Accessories:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.0369%;\"\u003e 8212-USB\u003c\/td\u003e\n\u003ctd style=\"width: 73.9631%;\"\u003eUSB adapter with \"KEW Report (Software)\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eDownload\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/3551_3552_3552BT_1E_L.pdf?12375626206283735792\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/3551_3552_3552BT_IM_92-2339_E_L.pdf?11265191022118200594\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Kyoritsu","offers":[{"title":"Default Title","offer_id":13721166905388,"sku":"KEW3552","price":811.3,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/KEW3552.png?v=1549553953"},{"product_id":"kyoritsu-3552-1000v-digital-insulation-continuity-tester-with-memory-bluetooth-communication-function","title":"KYORITSU 3552BT 1000V Digital Insulation \/ Continuity Tester with Memory \u0026 Bluetooth Communication Function","description":"\u003cul\u003e\n\u003cli\u003eWorld’s fastest measurement speed (0.5 sec.)\u003c\/li\u003e\n\u003cli\u003eSix ranges available for insulation\u003c\/li\u003e\n\u003cli\u003eResistance test (50\/100\/125\/250\/500\/1000 V) up to 40 GOhm\u003c\/li\u003e\n\u003cli\u003eDiagnostic Insulation Test : PI, DAR\u003c\/li\u003e\n\u003cli\u003eAC\/DC Voltage Measurement\u003c\/li\u003e\n\u003cli\u003eContinuity Test @200mA\u003c\/li\u003e\n\u003cli\u003eLCD backlight and LED spot light facilitate working at dimly illuminated location or at nighttime work. The built-in illuminance sensor automatically turns on\/off the lights.\u003c\/li\u003e\n\u003cli\u003eTest probe comes with remote control switch (supplied)\u003c\/li\u003e\n\u003cli\u003eMemory function - can save 1000 results\u003c\/li\u003e\n\u003cli\u003eBluetooth communication function - free apps \"KEW Smart for KEW3552BT\" is available for free download at Google Play and App Store.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_backlight_large.png?v=1549479460\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_Auto_Power_Off_large.png?v=1549479497\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_50v_large.png?v=1549479525\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_100v_49d9f1f6-2f62-4095-b592-dcb5a761dd8f_large.png?v=1549479583\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_125v_large.png?v=1549479551\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_250v_large.png?v=1549479556\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_500v_large.png?v=1549479562\" alt=\"\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_1000v_large.png?v=1549479797\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_acdcv_large.png?v=1549479831\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_ohm_large.png?v=1549479847\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_usb_large.png?v=1549553656\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_bluetooth_large.png?v=1549561083\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eKEW3551 : Standard model\u003cbr\u003eKEW3552 : With memory function\u003cbr\u003eKEW3552BT : With memory and Bluetooth communication functions\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eThe right model for your application\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0185%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e6 ranges insulation resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003ePC comm.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.0185%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eKEW 3551\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%; text-align: left;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%; text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 24.0185%;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003eKEW 3552\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 24.0185%;\"\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e KEW3553BT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.9815%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 21%;\"\u003e\u003cspan style=\"color: #3d85c6;\"\u003e\u003cstrong\u003e*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eIncluded Accessories:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 99.8162%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e 7260（Test leads with remote control switch）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_7260_large.png?v=1549480880\" alt=\"\" width=\"100\" height=\"140\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e7261A（Test leads with alligator clip）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_7261_large.png?v=1549480920\" alt=\"\" width=\"120\" height=\"126\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e8017A（Extension prod long）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_8017A_large.png?v=1549480952\" alt=\"\" width=\"95\" height=\"113\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e9173（Carrying case）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_9173_large.png?v=1549480978\" alt=\"\" width=\"117\" height=\"103\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003e9121（Shoulder strap）\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/KEW_9121_large.png?v=1549480996\" alt=\"\" width=\"88\" height=\"118\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003eLR6（AA）（1.5V）x4\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59%;\"\u003eInstruction manual\u003c\/td\u003e\n\u003ctd style=\"width: 40.4528%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOptional Accessories:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.0369%;\"\u003e 8212-USB\u003c\/td\u003e\n\u003ctd style=\"width: 73.9631%;\"\u003eUSB adapter with \"KEW Report (Software)\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eDownload\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/3551_3552_3552BT_1E_L.pdf?12375626206283735792\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/3551_3552_3552BT_IM_92-2339_E_L.pdf?11265191022118200594\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Kyoritsu","offers":[{"title":"Default Title","offer_id":13721567658028,"sku":"KEW3552BT","price":941.11,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/KEW3552BT.png?v=1549557524"},{"product_id":"rental-sterling-insu5000","title":"Rental - Sterling insu5000AK 5KV Insulation Tester","description":"\u003cdiv class=\"noAround\"\u003e\n\u003cdiv class=\"productLeadText\"\u003eThis instrument is suited for the non-destructive measurement of insulation resistance in electrical systems, at machines and transformers and in cables, as well as within the electrical equipment of, for example, locomotives, tram systems and ocean going vessels, with eight selectable test voltages up to 5kV.\u003c\/div\u003e\n\u003cdiv class=\"productLeadText\"\u003e\n\u003cul\u003e\n\u003cli\u003eBroad measuring range from 10kOhm to 1TOhm\u003c\/li\u003e\n\u003cli\u003eEasy to read logarithmic display\u003c\/li\u003e\n\u003cli\u003eTest Voltages: 100V, 250V, 500V, 1000V, 1500V, 2000V, 2500V, 5000V\u003c\/li\u003e\n\u003cli\u003eVoltage measurement to 2000V\u003c\/li\u003e\n\u003cli\u003eGuard terminal eliminates surface current\u003c\/li\u003e\n\u003cli\u003ePower supply with batteries\u003c\/li\u003e\n\u003cli\u003ePower supply with hand  crank generator available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"productLeadText\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cdiv id=\"c7635\" class=\"csc-default\"\u003e\n\u003cdiv id=\"c7635\" class=\"csc-default\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eRental - Sterling MS-2301 \u003cb\u003ePackage Includes\u003c\/b\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003einsu5000AK meter (power supply with batteries)\u003c\/li\u003e\n\u003cli\u003eCarry Case\u003c\/li\u003e\n\u003cli\u003eCertificate of Calibration\u003c\/li\u003e\n\u003cli\u003eUser Manual \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDownload:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/Rish_insu_5000a_ak_datasheet.pdf?2001704209310645213\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/Rish_Insu_5000A_AK_User_Manual.pdf?2001704209310645213\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Sterling","offers":[{"title":"One week","offer_id":13817338658860,"sku":"Sterling-insu5000AK-Rental","price":195.0,"currency_code":"CAD","in_stock":true},{"title":"One Month","offer_id":13817338691628,"sku":"Sterling-insu5000AK-Rental","price":390.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/rental_Sterling_MS2301.png?v=1571001785"},{"product_id":"megabras-tentech-mi10kve","title":"Megabras Tentech MI10KVE – 10kV High-Voltage Digital Insulation Resistance Tester","description":"\u003cp data-start=\"300\" data-end=\"388\" class=\"\"\u003e\u003cstrong data-start=\"300\" data-end=\"388\"\u003eLaboratory-Grade 10kV Insulation Tester for Utilities, Power Plants \u0026amp; Heavy Industry\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"390\" data-end=\"878\" class=\"\"\u003e\u003cstrong data-start=\"390\" data-end=\"411\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"411\" data-end=\"414\"\u003eThe \u003cstrong data-start=\"418\" data-end=\"446\"\u003eMegabras Tentech MI10KVE\u003c\/strong\u003e is a \u003cstrong data-start=\"452\" data-end=\"505\"\u003ehigh-precision 10 kV insulation resistance tester\u003c\/strong\u003e engineered for \u003cstrong data-start=\"521\" data-end=\"566\"\u003eextreme high-voltage testing environments\u003c\/strong\u003e, including power generation, utilities, transformer manufacturing, and large-scale electrical installations. Offering test voltages from \u003cstrong data-start=\"704\" data-end=\"725\"\u003e500 V to 10,000 V\u003c\/strong\u003e and insulation resistance measurement up to \u003cstrong data-start=\"770\" data-end=\"780\"\u003e500 GΩ\u003c\/strong\u003e, it’s ideal for validating insulation in rotating machinery, HV cables, switchgear, and bushings.\u003c\/p\u003e\n\u003cp data-start=\"880\" data-end=\"1166\" class=\"\"\u003eDesigned for \u003cstrong data-start=\"893\" data-end=\"967\"\u003ereliability, repeatability, and compliance with IEEE 43-2000 standards\u003c\/strong\u003e, the MI10KVE includes \u003cstrong data-start=\"990\" data-end=\"1012\"\u003ePI\/DAR diagnostics\u003c\/strong\u003e, \u003cstrong data-start=\"1014\" data-end=\"1039\"\u003eUSB\/RS232 data export\u003c\/strong\u003e, and \u003cstrong data-start=\"1045\" data-end=\"1075\"\u003eprogrammable test profiles\u003c\/strong\u003e, making it an advanced solution for quality assurance and predictive maintenance programs.\u003c\/p\u003e\n\u003chr data-start=\"1168\" data-end=\"1171\" class=\"\"\u003e\n\u003ch3 data-start=\"1173\" data-end=\"1194\" class=\"\"\u003e\u003cstrong data-start=\"1177\" data-end=\"1194\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1195\" data-end=\"1719\"\u003e\n\u003cli data-start=\"1195\" data-end=\"1260\" class=\"\"\u003e\n\u003cp data-start=\"1197\" data-end=\"1260\" class=\"\"\u003e\u003cstrong data-start=\"1197\" data-end=\"1226\"\u003eSelectable Test Voltages:\u003c\/strong\u003e 500 V to 10,000 V in 25 V steps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1261\" data-end=\"1316\" class=\"\"\u003e\n\u003cp data-start=\"1263\" data-end=\"1316\" class=\"\"\u003e\u003cstrong data-start=\"1263\" data-end=\"1301\"\u003eInsulation Resistance Measurement:\u003c\/strong\u003e Up to 500 GΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1317\" data-end=\"1394\" class=\"\"\u003e\n\u003cp data-start=\"1319\" data-end=\"1394\" class=\"\"\u003e\u003cstrong data-start=\"1319\" data-end=\"1384\"\u003ePI (Polarization Index) and DAR (Dielectric Absorption Ratio)\u003c\/strong\u003e testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1395\" data-end=\"1448\" class=\"\"\u003e\n\u003cp data-start=\"1397\" data-end=\"1448\" class=\"\"\u003e\u003cstrong data-start=\"1397\" data-end=\"1446\"\u003eGraphical Backlit Display with Trend Plotting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1513\" class=\"\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1513\" class=\"\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1511\"\u003eUSB \u0026amp; RS232 Interfaces for Data Logging and PC Reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1514\" data-end=\"1561\" class=\"\"\u003e\n\u003cp data-start=\"1516\" data-end=\"1561\" class=\"\"\u003e\u003cstrong data-start=\"1516\" data-end=\"1559\"\u003eAutomatic Discharge of Capacitive Loads\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1562\" data-end=\"1613\" class=\"\"\u003e\n\u003cp data-start=\"1564\" data-end=\"1613\" class=\"\"\u003e\u003cstrong data-start=\"1564\" data-end=\"1611\"\u003eTimer, Ramp, and Step Voltage Testing Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1614\" data-end=\"1671\" class=\"\"\u003e\n\u003cp data-start=\"1616\" data-end=\"1671\" class=\"\"\u003e\u003cstrong data-start=\"1616\" data-end=\"1669\"\u003eHeavy-Duty Construction with Shock-Resistant Case\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1672\" data-end=\"1719\" class=\"\"\u003e\n\u003cp data-start=\"1674\" data-end=\"1719\" class=\"\"\u003e\u003cstrong data-start=\"1674\" data-end=\"1719\"\u003eComplies with IEC 61010-1, CAT III 1000 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1721\" data-end=\"1724\" class=\"\"\u003e\n\u003ch3 data-start=\"1726\" data-end=\"1743\" class=\"\"\u003e\u003cstrong data-start=\"1730\" data-end=\"1743\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1744\" data-end=\"1916\"\u003e\n\u003cli data-start=\"1744\" data-end=\"1779\" class=\"\"\u003e\n\u003cp data-start=\"1746\" data-end=\"1779\" class=\"\"\u003ePower utilities and substations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1780\" data-end=\"1823\" class=\"\"\u003e\n\u003cp data-start=\"1782\" data-end=\"1823\" class=\"\"\u003eTransformer and generator manufacturers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1824\" data-end=\"1866\" class=\"\"\u003e\n\u003cp data-start=\"1826\" data-end=\"1866\" class=\"\"\u003eHigh-voltage research and quality labs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1867\" data-end=\"1916\" class=\"\"\u003e\n\u003cp data-start=\"1869\" data-end=\"1916\" class=\"\"\u003ePredictive maintenance in energy infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1918\" data-end=\"1921\" class=\"\"\u003e\n\u003ch3 data-start=\"1923\" data-end=\"1947\" class=\"\"\u003e\u003cstrong data-start=\"1927\" data-end=\"1947\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1948\" data-end=\"2150\"\u003e\n\u003cli data-start=\"1948\" data-end=\"1986\" class=\"\"\u003e\n\u003cp data-start=\"1950\" data-end=\"1986\" class=\"\"\u003eMegabras MI10KVE Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1987\" data-end=\"2025\" class=\"\"\u003e\n\u003cp data-start=\"1989\" data-end=\"2025\" class=\"\"\u003eHigh-voltage test leads with clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2026\" data-end=\"2048\" class=\"\"\u003e\n\u003cp data-start=\"2028\" data-end=\"2048\" class=\"\"\u003eUSB \u0026amp; RS232 cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2049\" data-end=\"2086\" class=\"\"\u003e\n\u003cp data-start=\"2051\" data-end=\"2086\" class=\"\"\u003ePC software for report generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2087\" data-end=\"2108\" class=\"\"\u003e\n\u003cp data-start=\"2089\" data-end=\"2108\" class=\"\"\u003eRugged carry case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2109\" data-end=\"2150\" class=\"\"\u003e\n\u003cp data-start=\"2111\" data-end=\"2150\" class=\"\"\u003eCalibration certificate and user manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2152\" data-end=\"2155\" class=\"\"\u003e\n\u003ch3 data-start=\"2157\" data-end=\"2184\" class=\"\"\u003e🔍 \u003cstrong data-start=\"2164\" data-end=\"2184\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2185\" data-end=\"3155\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2185\" data-end=\"2304\"\u003e\n\u003ctr data-start=\"2185\" data-end=\"2304\"\u003e\n\u003cth data-start=\"2185\" data-end=\"2220\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2220\" data-end=\"2245\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2222\" data-end=\"2242\"\u003eMegabras MI10KVE\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2245\" data-end=\"2273\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2247\" data-end=\"2261\"\u003eFluke 1555\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2273\" data-end=\"2304\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2275\" data-end=\"2293\"\u003eMetrel MI 3201\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2428\" data-end=\"3155\"\u003e\n\u003ctr data-start=\"2428\" data-end=\"2550\"\u003e\n\u003ctd data-start=\"2428\" data-end=\"2463\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2463\" data-end=\"2489\"\u003e10,000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2489\" data-end=\"2518\"\u003e10,000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2518\" data-end=\"2550\"\u003e5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2551\" data-end=\"2673\"\u003e\n\u003ctd data-start=\"2551\" data-end=\"2586\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2586\" data-end=\"2612\"\u003e500 GΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2612\" data-end=\"2641\"\u003e2 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2641\" data-end=\"2673\"\u003e10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2674\" data-end=\"2793\"\u003e\n\u003ctd data-start=\"2674\" data-end=\"2709\" data-col-size=\"sm\"\u003ePI\/DAR Capability\u003c\/td\u003e\n\u003ctd data-start=\"2709\" data-end=\"2734\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2734\" data-end=\"2762\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2762\" data-end=\"2793\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2794\" data-end=\"2913\"\u003e\n\u003ctd data-start=\"2794\" data-end=\"2829\" data-col-size=\"sm\"\u003eData Export\u003c\/td\u003e\n\u003ctd data-start=\"2829\" data-end=\"2854\" data-col-size=\"sm\"\u003e✅ USB + RS232\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2854\" data-end=\"2882\"\u003e✅ USB\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2882\" data-end=\"2913\"\u003e✅ USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2914\" data-end=\"3033\"\u003e\n\u003ctd data-start=\"2914\" data-end=\"2949\" data-col-size=\"sm\"\u003eGraphical Display\u003c\/td\u003e\n\u003ctd data-start=\"2949\" data-end=\"2974\" data-col-size=\"sm\"\u003e✅ Trend graph + numeric\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2974\" data-end=\"3002\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3002\" data-end=\"3033\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3034\" data-end=\"3155\"\u003e\n\u003ctd data-start=\"3034\" data-end=\"3069\" data-col-size=\"sm\"\u003eBest Use\u003c\/td\u003e\n\u003ctd data-start=\"3069\" data-end=\"3097\" data-col-size=\"sm\"\u003eLab + field, 10kV testing\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3097\" data-end=\"3123\"\u003eUtility \u0026amp; HV equipment\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3123\" data-end=\"3155\"\u003eIndustrial diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MEGABRAS","offers":[{"title":"Default Title","offer_id":14537062776876,"sku":"MGMI10KV","price":2750.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/mi10kve.jpg?v=1556720193"},{"product_id":"megabras-tentech-mi15kve","title":"Megabras Tentech MI15KVE – 15kV High-Voltage Digital Insulation Resistance Tester","description":"\u003cp data-start=\"280\" data-end=\"383\" class=\"\"\u003e\u003cstrong data-start=\"280\" data-end=\"383\"\u003eUltra High-Voltage Insulation Testing up to 15kV – Designed for Power Utilities and Industrial Labs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"385\" data-end=\"871\" class=\"\"\u003e\u003cstrong data-start=\"385\" data-end=\"406\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"406\" data-end=\"409\"\u003eThe \u003cstrong data-start=\"413\" data-end=\"441\"\u003eMegabras Tentech MI15KVE\u003c\/strong\u003e is a \u003cstrong data-start=\"447\" data-end=\"496\"\u003etop-tier 15,000V insulation resistance tester\u003c\/strong\u003e engineered for the most demanding electrical testing environments, including \u003cstrong data-start=\"574\" data-end=\"672\"\u003epower transmission systems, transformer stations, generator manufacturing, and HV laboratories\u003c\/strong\u003e. With insulation resistance measurement up to \u003cstrong data-start=\"719\" data-end=\"727\"\u003e1 TΩ\u003c\/strong\u003e and \u003cstrong data-start=\"732\" data-end=\"783\"\u003etest voltages selectable from 500 V to 15,000 V\u003c\/strong\u003e, it provides unparalleled flexibility and precision in ultra high-voltage applications.\u003c\/p\u003e\n\u003cp data-start=\"873\" data-end=\"1137\" class=\"\"\u003ePacked with features such as \u003cstrong data-start=\"902\" data-end=\"929\"\u003ePI (Polarization Index)\u003c\/strong\u003e and \u003cstrong data-start=\"934\" data-end=\"971\"\u003eDAR (Dielectric Absorption Ratio)\u003c\/strong\u003e testing, \u003cstrong data-start=\"981\" data-end=\"1003\"\u003egraphical trending\u003c\/strong\u003e, and \u003cstrong data-start=\"1009\" data-end=\"1034\"\u003eUSB\/RS232 data export\u003c\/strong\u003e, the MI15KVE supports standards-compliant diagnostics and long-term predictive maintenance strategies.\u003c\/p\u003e\n\u003chr data-start=\"1139\" data-end=\"1142\" class=\"\"\u003e\n\u003ch3 data-start=\"1144\" data-end=\"1165\" class=\"\"\u003e\u003cstrong data-start=\"1148\" data-end=\"1165\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1166\" data-end=\"1703\"\u003e\n\u003cli data-start=\"1166\" data-end=\"1225\" class=\"\"\u003e\n\u003cp data-start=\"1168\" data-end=\"1225\" class=\"\"\u003e\u003cstrong data-start=\"1168\" data-end=\"1191\"\u003eTest Voltage Range:\u003c\/strong\u003e 500 V to 15,000 V in 25 V steps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1226\" data-end=\"1284\" class=\"\"\u003e\n\u003cp data-start=\"1228\" data-end=\"1284\" class=\"\"\u003e\u003cstrong data-start=\"1228\" data-end=\"1260\"\u003eInsulation Resistance Range:\u003c\/strong\u003e Up to 1 TΩ (1,000 GΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1360\" class=\"\"\u003e\n\u003cp data-start=\"1287\" data-end=\"1360\" class=\"\"\u003e\u003cstrong data-start=\"1287\" data-end=\"1309\"\u003ePI and DAR Testing\u003c\/strong\u003e – Evaluate insulation aging and moisture content\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1361\" data-end=\"1430\" class=\"\"\u003e\n\u003cp data-start=\"1363\" data-end=\"1430\" class=\"\"\u003e\u003cstrong data-start=\"1363\" data-end=\"1394\"\u003eReal-Time Graphical Display\u003c\/strong\u003e with trending and digital readout\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1431\" data-end=\"1498\" class=\"\"\u003e\n\u003cp data-start=\"1433\" data-end=\"1498\" class=\"\"\u003e\u003cstrong data-start=\"1433\" data-end=\"1456\"\u003eUSB and RS232 Ports\u003c\/strong\u003e for data download and report generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1499\" data-end=\"1534\" class=\"\"\u003e\n\u003cp data-start=\"1501\" data-end=\"1534\" class=\"\"\u003e\u003cstrong data-start=\"1501\" data-end=\"1532\"\u003eRamp and Step Voltage Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1535\" data-end=\"1585\" class=\"\"\u003e\n\u003cp data-start=\"1537\" data-end=\"1585\" class=\"\"\u003e\u003cstrong data-start=\"1537\" data-end=\"1583\"\u003eAuto Discharge and Safety Lockout Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1586\" data-end=\"1642\" class=\"\"\u003e\n\u003cp data-start=\"1588\" data-end=\"1642\" class=\"\"\u003e\u003cstrong data-start=\"1588\" data-end=\"1640\"\u003eHeavy-Duty Industrial Housing with Carrying Case\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1643\" data-end=\"1703\" class=\"\"\u003e\n\u003cp data-start=\"1645\" data-end=\"1703\" class=\"\"\u003e\u003cstrong data-start=\"1645\" data-end=\"1703\"\u003eComplies with IEC 61010-1 CAT III 1000V \u0026amp; IEEE 43-2000\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1705\" data-end=\"1708\" class=\"\"\u003e\n\u003ch3 data-start=\"1710\" data-end=\"1727\" class=\"\"\u003e\u003cstrong data-start=\"1714\" data-end=\"1727\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1728\" data-end=\"1929\"\u003e\n\u003cli data-start=\"1728\" data-end=\"1778\" class=\"\"\u003e\n\u003cp data-start=\"1730\" data-end=\"1778\" class=\"\"\u003eHigh-voltage laboratories and R\u0026amp;D environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1779\" data-end=\"1827\" class=\"\"\u003e\n\u003cp data-start=\"1781\" data-end=\"1827\" class=\"\"\u003ePower transmission companies and substations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1828\" data-end=\"1874\" class=\"\"\u003e\n\u003cp data-start=\"1830\" data-end=\"1874\" class=\"\"\u003eTransformer and generator manufacturing QA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1875\" data-end=\"1929\" class=\"\"\u003e\n\u003cp data-start=\"1877\" data-end=\"1929\" class=\"\"\u003eElectrical utilities and large industrial facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1931\" data-end=\"1934\" class=\"\"\u003e\n\u003ch3 data-start=\"1936\" data-end=\"1960\" class=\"\"\u003e\u003cstrong data-start=\"1940\" data-end=\"1960\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1961\" data-end=\"2184\"\u003e\n\u003cli data-start=\"1961\" data-end=\"2007\" class=\"\"\u003e\n\u003cp data-start=\"1963\" data-end=\"2007\" class=\"\"\u003eMegabras Tentech MI15KVE Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2008\" data-end=\"2055\" class=\"\"\u003e\n\u003cp data-start=\"2010\" data-end=\"2055\" class=\"\"\u003eHigh-voltage shielded test leads with clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2056\" data-end=\"2088\" class=\"\"\u003e\n\u003cp data-start=\"2058\" data-end=\"2088\" class=\"\"\u003eUSB \u0026amp; RS232 interface cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2089\" data-end=\"2118\" class=\"\"\u003e\n\u003cp data-start=\"2091\" data-end=\"2118\" class=\"\"\u003eCarrying and storage case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2119\" data-end=\"2150\" class=\"\"\u003e\n\u003cp data-start=\"2121\" data-end=\"2150\" class=\"\"\u003ePC software and user manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2151\" data-end=\"2184\" class=\"\"\u003e\n\u003cp data-start=\"2153\" data-end=\"2184\" class=\"\"\u003eFactory calibration certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2186\" data-end=\"2189\" class=\"\"\u003e\n\u003ch3 data-start=\"2191\" data-end=\"2218\" class=\"\"\u003e🔍 \u003cstrong data-start=\"2198\" data-end=\"2218\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2219\" data-end=\"3212\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2219\" data-end=\"2339\"\u003e\n\u003ctr data-start=\"2219\" data-end=\"2339\"\u003e\n\u003cth data-start=\"2219\" data-end=\"2253\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2253\" data-end=\"2279\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2255\" data-end=\"2275\"\u003eMegabras MI15KVE\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2279\" data-end=\"2308\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2281\" data-end=\"2295\"\u003eFluke 1555\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2308\" data-end=\"2339\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2310\" data-end=\"2328\"\u003eMetrel MI 3205\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2466\" data-end=\"3212\"\u003e\n\u003ctr data-start=\"2466\" data-end=\"2591\"\u003e\n\u003ctd data-start=\"2466\" data-end=\"2501\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2501\" data-end=\"2529\"\u003e15,000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2529\" data-end=\"2559\"\u003e10,000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2559\" data-end=\"2591\"\u003e5,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2592\" data-end=\"2717\"\u003e\n\u003ctd data-start=\"2592\" data-end=\"2627\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-start=\"2627\" data-end=\"2655\" data-col-size=\"sm\"\u003e1 TΩ\u003c\/td\u003e\n\u003ctd data-start=\"2655\" data-end=\"2685\" data-col-size=\"sm\"\u003e2 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2685\" data-end=\"2717\"\u003e10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2718\" data-end=\"2840\"\u003e\n\u003ctd data-start=\"2718\" data-end=\"2753\" data-col-size=\"sm\"\u003ePI\/DAR Capability\u003c\/td\u003e\n\u003ctd data-start=\"2753\" data-end=\"2780\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2780\" data-end=\"2809\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-start=\"2809\" data-end=\"2840\" data-col-size=\"sm\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2841\" data-end=\"2963\"\u003e\n\u003ctd data-start=\"2841\" data-end=\"2876\" data-col-size=\"sm\"\u003eGraphical Display\u003c\/td\u003e\n\u003ctd data-start=\"2876\" data-end=\"2903\" data-col-size=\"sm\"\u003e✅ Yes (with trending)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2903\" data-end=\"2932\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2932\" data-end=\"2963\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2964\" data-end=\"3086\"\u003e\n\u003ctd data-start=\"2964\" data-end=\"2999\" data-col-size=\"sm\"\u003eData Logging \u0026amp; Export\u003c\/td\u003e\n\u003ctd data-start=\"2999\" data-end=\"3026\" data-col-size=\"sm\"\u003e✅ USB + RS232\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3026\" data-end=\"3055\"\u003e✅ USB\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3055\" data-end=\"3086\"\u003e✅ USB + RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3087\" data-end=\"3212\"\u003e\n\u003ctd data-start=\"3087\" data-end=\"3122\" data-col-size=\"sm\"\u003eIdeal For\u003c\/td\u003e\n\u003ctd data-start=\"3122\" data-end=\"3150\" data-col-size=\"sm\"\u003eHV labs, substations, QA\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3150\" data-end=\"3180\"\u003eField HV equipment testing\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3180\" data-end=\"3212\"\u003eLab\/industrial diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\"\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cbutton class=\"bg-token-bg-primary hover:bg-token-bg-tertiary text-token-text-secondary my-1 rounded-sm p-1 transition-opacity group-[:not(:hover):not(:focus-within)]:pointer-events-none group-[:not(:hover):not(:focus-within)]:opacity-0\"\u003e\u003csvg width=\"24\" height=\"24\" viewbox=\"0 0 24 24\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"icon-md-heavy\"\u003e\u003cpath fill-rule=\"evenodd\" clip-rule=\"evenodd\" d=\"M7 5C7 3.34315 8.34315 2 10 2H19C20.6569 2 22 3.34315 22 5V14C22 15.6569 20.6569 17 19 17H17V19C17 20.6569 15.6569 22 14 22H5C3.34315 22 2 20.6569 2 19V10C2 8.34315 3.34315 7 5 7H7V5ZM9 7H14C15.6569 7 17 8.34315 17 10V15H19C19.5523 15 20 14.5523 20 14V5C20 4.44772 19.5523 4 19 4H10C9.44772 4 9 4.44772 9 5V7ZM5 9C4.44772 9 4 9.44772 4 10V19C4 19.5523 4.44772 20 5 20H14C14.5523 20 15 19.5523 15 19V10C15 9.44772 14.5523 9 14 9H5Z\" fill=\"currentColor\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MEGABRAS","offers":[{"title":"Default Title","offer_id":14537344155692,"sku":"MGMI15KV","price":3470.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/mi15kve.jpg?v=1556720622"},{"product_id":"megabras-tentech-md15kvr","title":"Megabras Tentech MD15KVR – 15kV Digital Insulation Resistance Tester","description":"\u003cp data-start=\"280\" data-end=\"371\" class=\"\"\u003e\u003cstrong data-start=\"280\" data-end=\"371\"\u003eAdvanced, Portable 15kV Insulation Tester for Utilities, HV Labs, and Field Diagnostics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"373\" data-end=\"792\" class=\"\"\u003e\u003cstrong data-start=\"373\" data-end=\"394\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"394\" data-end=\"397\"\u003eThe \u003cstrong data-start=\"401\" data-end=\"429\"\u003eMegabras Tentech MD15KVR\u003c\/strong\u003e is a robust and portable \u003cstrong data-start=\"455\" data-end=\"500\"\u003e15kV digital insulation resistance tester\u003c\/strong\u003e designed for \u003cstrong data-start=\"514\" data-end=\"564\"\u003ehigh-voltage field and laboratory applications\u003c\/strong\u003e. With test voltages up to 15,000 V and insulation resistance measurement capability up to \u003cstrong data-start=\"655\" data-end=\"665\"\u003e500 GΩ\u003c\/strong\u003e, it provides the performance required for testing generators, cables, transformers, switchgear, and other high-voltage assets.\u003c\/p\u003e\n\u003cp data-start=\"794\" data-end=\"1136\" class=\"\"\u003eThis model combines precision and usability with features such as \u003cstrong data-start=\"860\" data-end=\"889\"\u003ereal-time digital display\u003c\/strong\u003e, \u003cstrong data-start=\"891\" data-end=\"927\"\u003estep voltage and ramp test modes\u003c\/strong\u003e, \u003cstrong data-start=\"929\" data-end=\"958\"\u003eautomatic PI\/DAR analysis\u003c\/strong\u003e, and \u003cstrong data-start=\"964\" data-end=\"990\"\u003eUSB\/RS232 connectivity\u003c\/strong\u003e. Designed for the rigors of field work, it comes housed in a \u003cstrong data-start=\"1052\" data-end=\"1086\"\u003eweather-resistant, rugged case\u003c\/strong\u003e and complies with international safety standards.\u003c\/p\u003e\n\u003chr data-start=\"1138\" data-end=\"1141\" class=\"\"\u003e\n\u003ch3 data-start=\"1143\" data-end=\"1164\" class=\"\"\u003e\u003cstrong data-start=\"1147\" data-end=\"1164\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1165\" data-end=\"1689\"\u003e\n\u003cli data-start=\"1165\" data-end=\"1229\" class=\"\"\u003e\n\u003cp data-start=\"1167\" data-end=\"1229\" class=\"\"\u003e\u003cstrong data-start=\"1167\" data-end=\"1195\"\u003eAdjustable Test Voltage:\u003c\/strong\u003e 500 V to 15,000 V in 25 V steps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1285\" class=\"\"\u003e\n\u003cp data-start=\"1232\" data-end=\"1285\" class=\"\"\u003e\u003cstrong data-start=\"1232\" data-end=\"1270\"\u003eInsulation Resistance Measurement:\u003c\/strong\u003e Up to 500 GΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1286\" data-end=\"1353\" class=\"\"\u003e\n\u003cp data-start=\"1288\" data-end=\"1353\" class=\"\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1310\"\u003ePI and DAR Testing\u003c\/strong\u003e – Automatically calculated and displayed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1354\" data-end=\"1394\" class=\"\"\u003e\n\u003cp data-start=\"1356\" data-end=\"1394\" class=\"\"\u003e\u003cstrong data-start=\"1356\" data-end=\"1392\"\u003eStep Voltage and Ramp Test Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1395\" data-end=\"1436\" class=\"\"\u003e\n\u003cp data-start=\"1397\" data-end=\"1436\" class=\"\"\u003e\u003cstrong data-start=\"1397\" data-end=\"1434\"\u003eDigital LCD Display with Bargraph\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1437\" data-end=\"1500\" class=\"\"\u003e\n\u003cp data-start=\"1439\" data-end=\"1500\" class=\"\"\u003e\u003cstrong data-start=\"1439\" data-end=\"1465\"\u003eUSB \u0026amp; RS232 Interfaces\u003c\/strong\u003e for PC data export and reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1501\" data-end=\"1561\" class=\"\"\u003e\n\u003cp data-start=\"1503\" data-end=\"1561\" class=\"\"\u003e\u003cstrong data-start=\"1503\" data-end=\"1559\"\u003eAutomatic Discharge and Test Inhibit Safety Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1562\" data-end=\"1613\" class=\"\"\u003e\n\u003cp data-start=\"1564\" data-end=\"1613\" class=\"\"\u003e\u003cstrong data-start=\"1564\" data-end=\"1611\"\u003eRechargeable Battery and AC Power Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1614\" data-end=\"1689\" class=\"\"\u003e\n\u003cp data-start=\"1616\" data-end=\"1689\" class=\"\"\u003e\u003cstrong data-start=\"1616\" data-end=\"1689\"\u003eCAT III 1000V Safety Rated \/ Complies with IEC 61010 and IEEE 43-2000\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1691\" data-end=\"1694\" class=\"\"\u003e\n\u003ch3 data-start=\"1696\" data-end=\"1713\" class=\"\"\u003e\u003cstrong data-start=\"1700\" data-end=\"1713\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1714\" data-end=\"1948\"\u003e\n\u003cli data-start=\"1714\" data-end=\"1768\" class=\"\"\u003e\n\u003cp data-start=\"1716\" data-end=\"1768\" class=\"\"\u003eElectrical utility substations and field engineers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1769\" data-end=\"1811\" class=\"\"\u003e\n\u003cp data-start=\"1771\" data-end=\"1811\" class=\"\"\u003eTransformer and motor manufacturing QA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1812\" data-end=\"1850\" class=\"\"\u003e\n\u003cp data-start=\"1814\" data-end=\"1850\" class=\"\"\u003eHigh-voltage equipment maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1851\" data-end=\"1893\" class=\"\"\u003e\n\u003cp data-start=\"1853\" data-end=\"1893\" class=\"\"\u003eHV cable testing in harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1894\" data-end=\"1948\" class=\"\"\u003e\n\u003cp data-start=\"1896\" data-end=\"1948\" class=\"\"\u003eField diagnostics and long-range insulation analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1950\" data-end=\"1953\" class=\"\"\u003e\n\u003ch3 data-start=\"1955\" data-end=\"1979\" class=\"\"\u003e\u003cstrong data-start=\"1959\" data-end=\"1979\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1980\" data-end=\"2195\"\u003e\n\u003cli data-start=\"1980\" data-end=\"2031\" class=\"\"\u003e\n\u003cp data-start=\"1982\" data-end=\"2031\" class=\"\"\u003eMegabras Tentech MD15KVR 15kV Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2032\" data-end=\"2070\" class=\"\"\u003e\n\u003cp data-start=\"2034\" data-end=\"2070\" class=\"\"\u003eShielded HV test leads with clamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2071\" data-end=\"2105\" class=\"\"\u003e\n\u003cp data-start=\"2073\" data-end=\"2105\" class=\"\"\u003eUSB and RS232 interface cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2106\" data-end=\"2132\" class=\"\"\u003e\n\u003cp data-start=\"2108\" data-end=\"2132\" class=\"\"\u003ePC software and manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2133\" data-end=\"2159\" class=\"\"\u003e\n\u003cp data-start=\"2135\" data-end=\"2159\" class=\"\"\u003eRugged waterproof case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2160\" data-end=\"2195\" class=\"\"\u003e\n\u003cp data-start=\"2162\" data-end=\"2195\" class=\"\"\u003eFactory calibration certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2197\" data-end=\"2200\" class=\"\"\u003e\n\u003ch3 data-start=\"2202\" data-end=\"2229\" class=\"\"\u003e🔍 \u003cstrong data-start=\"2209\" data-end=\"2229\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2230\" data-end=\"3387\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2230\" data-end=\"2354\"\u003e\n\u003ctr data-start=\"2230\" data-end=\"2354\"\u003e\n\u003cth data-start=\"2230\" data-end=\"2264\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2264\" data-end=\"2291\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2266\" data-end=\"2286\"\u003eMegabras MD15KVR\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2291\" data-end=\"2322\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2293\" data-end=\"2313\"\u003eMegabras MI15KVE\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2322\" data-end=\"2354\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2324\" data-end=\"2342\"\u003eMetrel MI 3210\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2485\" data-end=\"3387\"\u003e\n\u003ctr data-start=\"2485\" data-end=\"2614\"\u003e\n\u003ctd data-start=\"2485\" data-end=\"2520\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2520\" data-end=\"2549\" data-col-size=\"sm\"\u003e15,000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2549\" data-end=\"2581\"\u003e15,000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2581\" data-end=\"2614\"\u003e10,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2615\" data-end=\"2744\"\u003e\n\u003ctd data-start=\"2615\" data-end=\"2650\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2650\" data-end=\"2679\"\u003e500 GΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2679\" data-end=\"2711\"\u003e1 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2711\" data-end=\"2744\"\u003e10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2745\" data-end=\"2871\"\u003e\n\u003ctd data-start=\"2745\" data-end=\"2780\" data-col-size=\"sm\"\u003ePI\/DAR Testing\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2780\" data-end=\"2808\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2808\" data-end=\"2839\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2839\" data-end=\"2871\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2872\" data-end=\"3001\"\u003e\n\u003ctd data-start=\"2872\" data-end=\"2907\" data-col-size=\"sm\"\u003eTest Modes\u003c\/td\u003e\n\u003ctd data-start=\"2907\" data-end=\"2936\" data-col-size=\"sm\"\u003eStep, Ramp, Timer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2936\" data-end=\"2968\"\u003eStep, Ramp, Timer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2968\" data-end=\"3001\"\u003eStep, Ramp, Timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3002\" data-end=\"3131\"\u003e\n\u003ctd data-start=\"3002\" data-end=\"3037\" data-col-size=\"sm\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3037\" data-end=\"3066\"\u003eDigital + Bargraph\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3066\" data-end=\"3098\"\u003eGraphical LCD\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3098\" data-end=\"3131\"\u003eGraphical LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3132\" data-end=\"3258\"\u003e\n\u003ctd data-start=\"3132\" data-end=\"3167\" data-col-size=\"sm\"\u003ePC Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3167\" data-end=\"3195\"\u003e✅ USB + RS232\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3195\" data-end=\"3226\"\u003e✅ USB + RS232\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3226\" data-end=\"3258\"\u003e✅ USB + RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3259\" data-end=\"3387\"\u003e\n\u003ctd data-start=\"3259\" data-end=\"3294\" data-col-size=\"sm\"\u003eBest Use\u003c\/td\u003e\n\u003ctd data-start=\"3294\" data-end=\"3323\" data-col-size=\"sm\"\u003eRugged field diagnostics\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3323\" data-end=\"3355\"\u003eGeneral HV lab and utility\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3355\" data-end=\"3387\"\u003eHigh-precision lab and field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MEGABRAS","offers":[{"title":"Default Title","offer_id":14538706419756,"sku":"MD15KVR","price":6050.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/MD15KVR.jpg?v=1556734929"},{"product_id":"sterling-360-1000v-digital-insulation-tester","title":"Sterling 360 1000V Digital Insulation \/ Continuity Tester","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003e 4 Digits LCD Display\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e Auto Range For MΩ \u0026amp; Ω\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003e40 Segments Analog Display\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003eTest Hold Function For Easy Operation\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003eAutomatic Zero To Null Lead Resistance\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003eEasy To Carry\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003eDischarge Indication Beeper For MΩ Range\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003e1mA Test Current For MΩ Range At Rated Voltage\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003e200mA Short Current For Continuity Range\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan\u003e\u003cspan color=\"#696969\" style=\"color: #696969;\"\u003e\u003cstrong\u003e\u003cu\u003e\u003cspan size=\"3\" style=\"font-size: medium;\"\u003eSPECIFICATIONS\u003c\/span\u003e\u003c\/u\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e \n\u003ctable align=\"center\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"text-align: left;\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan color=\"#696969\" style=\"color: #696969;\"\u003eACV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan color=\"#696969\" style=\"color: #696969;\"\u003e600V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5%rdg+3dgts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan color=\"#696969\" style=\"color: #696969;\"\u003eDCV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan color=\"#696969\" style=\"color: #696969;\"\u003e600V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1%rdg+3dgts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400Ω~4000Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1Ω~10KΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1%rdg+5dgts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\/40\/400\/4000MΩ\u003cbr\u003e(250V\/500V\/1000V)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1KΩ~1MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3%rdg+5dgts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e•)))_Active Sound Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003e\u003cspan\u003e≦ 40Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable align=\"center\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay: 76x42mm LCD panel with 40 segments analog bar indication\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSampling Rate: 2.5 times\/sec digital display; 10 times\/sec bar graph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery: 1.5V size AA battery x 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions: 196x112x64 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight: 700g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eDownload\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/CENTER360.pdf?21\"\u003eDatasheet\u003c\/a\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":14619296301100,"sku":"CE360","price":199.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/CE360.jpg?v=1557766987"},{"product_id":"rental-sterling-smr-1000-1kv-hand-cranked-analogue-insulation-tester","title":"Rental:  Sterling SMR-1000 1KV Hand-Cranked Analogue Insulation Tester","description":"\u003cp\u003eSMR-1000 is a compact, roggedly constructed portable Insulation Resistance Tester with 3 test voltages up to 1000VDC. The hand-cranked generator turns smoothly and quietly, and its output is regulated for increased accuracy and reliable test results. The instrument is housed a die-cast aluminum body \u003cbr\u003e for use in harsh environments.\u003c\/p\u003e\n\u003cp\u003eFeatures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltages: 250\/500\/1000 VDC\u003c\/li\u003e\n\u003cli\u003eInsulaton ranges: 250\/500\/1000 Mega Ohms\u003c\/li\u003e\n\u003cli\u003eLarge, easy to read analogue scale\u003c\/li\u003e\n\u003cli\u003eReliable hand crank operation\u003c\/li\u003e\n\u003cli\u003eRugged die-cast housing\u003c\/li\u003e\n\u003cli\u003eHard Carrying Case supplied\u003c\/li\u003e\n\u003cli\u003eGUARD Terminal eliminate surface leakage current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eSpecifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"2\" border=\"0\" style=\"width: 510px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 36px;\"\u003e\n\u003ctd style=\"height: 36px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTest Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 36px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e250V\/500V\/1000V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17px;\"\u003e\n\u003ctd style=\"height: 17px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eMeasuring Ranges \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 17px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e250MΩ\/500MΩ\/1000MΩ \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 11px;\"\u003e\n\u003ctd style=\"height: 11px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 11px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eClass 1.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 36px;\"\u003e\n\u003ctd style=\"height: 36px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eCranking Speed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 36px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e150r\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eLength of Scale\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 57px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eApprox. 80mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30px;\"\u003e\n\u003ctd style=\"height: 30px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 30px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e215mm x 135mm x 130mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 6px;\"\u003e\n\u003ctd style=\"height: 6px; width: 221px;\"\u003eTemperature \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd style=\"height: 6px; width: 278px;\"\u003e-20 degC to 50degC, humidity \u0026lt;\u003cbr\u003e 85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 36px;\"\u003e\n\u003ctd style=\"height: 36px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003eExternal Magnett \u003cbr\u003e Field Influence\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 36px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e\u0026lt;1% of full scall length at a \u003cbr\u003e Magnet Field Influence of 5 \u003c\/span\u003eOersted\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 36px;\"\u003e\n\u003ctd style=\"height: 36px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 36px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eApprox. 2.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 36px;\"\u003e\n\u003ctd style=\"height: 36px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eDamping Time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 36px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eWithin 4 sec\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 49.5469px;\"\u003e\n\u003ctd style=\"height: 49.5469px; width: 221px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 49.5469px; width: 278px;\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003eTest leads, carrying case and \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003eInstruction Manual, certificate of calibration (available upon request)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Sterling","offers":[{"title":"One week","offer_id":30885995511852,"sku":"QDSMR1000-1","price":95.0,"currency_code":"CAD","in_stock":true},{"title":"One Month","offer_id":30885995544620,"sku":"QDSMR1000-2","price":195.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/smr1000_447c29d0-5d79-480b-a4f2-18bf0cc5b753.jpg?v=1571401830"},{"product_id":"r5002-high-voltage-insulation-tester","title":"R5002 High Voltage Insulation Tester","description":"\u003cp\u003e\u003cspan\u003eTest voltages up to 5kV and measure insulation resistance up to 60GΩ. The R5002 performs a spot insulation test by applying a regulated and stabilized voltage to measure the amount of flowing current and then calculates resistance in order to evaluate insulation integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eHigh Voltage Insulation Tester\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWide range measurements from 500V to 5000V and up to 60GΩ.\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge 6000 counts digital display with bargraph and backlight.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePolarization index measurement(PI).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto ranging \u0026amp; Timer measurement function.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndication of output voltage and discharge voltage.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto-discharge function and voltage output warning function.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto power off and battery check.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMAX\/MIN, PEAK, Relative value \u0026amp; Data hold functions for DC\/AC voltage measurments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSafety standard IEC61010-1 CAT IV 600V\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e Included with R5002\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital High Voltage Insulation Tester\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eAC Adapter\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eR5002 Specifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e500V, 1000V, 2500V, 5000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e0 to 6MΩ, 0 to 60MΩ, 0 to 600MΩ, 0 to 6GΩ, 0 to 60GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC\/DC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 600Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Selection\u003c\/td\u003e\n\u003ctd\u003eManual \/ Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6000 count LCD display with bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax\/Min, Peak, Relative and Data Hold Functions\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e2.5 times\/sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklit Display\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Bargraph\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003ctd\u003eYes (after 20 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eYes (\u0026lt; 50Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e8 C Batteries or AC Adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Indicator\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT. IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e32 to 104°F (0 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 140°F (-20 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 5.8 x 3.4\" (198 x 148 x 86mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3lbs (1.5kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Duncan Instruments Canada Ltd","offers":[{"title":"Default Title","offer_id":31759353184353,"sku":"REEDR5002","price":975.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/58f726b3801ba.png?v=1580409957"},{"product_id":"copy-of-r5002-high-voltage-insulation-tester-c-w-calibration-certificate","title":"R5002 High Voltage Insulation Tester c\/w calibration certificate","description":"\u003cp\u003e\u003cspan\u003eTest voltages up to 5kV and measure insulation resistance up to 60GΩ. The R5002 performs a spot insulation test by applying a regulated and stabilized voltage to measure the amount of flowing current and then calculates resistance in order to evaluate insulation integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eHigh Voltage Insulation Tester\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWide range measurements from 500V to 5000V and up to 60GΩ.\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge 6000 counts digital display with bargraph and backlight.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePolarization index measurement(PI).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto ranging \u0026amp; Timer measurement function.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndication of output voltage and discharge voltage.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto-discharge function and voltage output warning function.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuto power off and battery check.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMAX\/MIN, PEAK, Relative value \u0026amp; Data hold functions for DC\/AC voltage measurments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSafety standard IEC61010-1 CAT IV 600V\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eR5002 Specifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e500V, 1000V, 2500V, 5000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e0 to 6MΩ, 0 to 60MΩ, 0 to 600MΩ, 0 to 6GΩ, 0 to 60GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC\/DC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 to 600Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Selection\u003c\/td\u003e\n\u003ctd\u003eManual \/ Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6000 count LCD display with bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax\/Min, Peak, Relative and Data Hold Functions\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e2.5 times\/sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklit Display\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Bargraph\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003ctd\u003eYes (after 20 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Buzzer\u003c\/td\u003e\n\u003ctd\u003eYes (\u0026lt; 50Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e8 C Batteries or AC Adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Indicator\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT. IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e32 to 104°F (0 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 140°F (-20 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 5.8 x 3.4\" (198 x 148 x 86mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3lbs (1.5kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Duncan Instruments Canada Ltd","offers":[{"title":"Default Title","offer_id":31759383625825,"sku":"REEDR5002-cert","price":1045.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/R5002-cert_88f38bbe-36c8-45b4-bf37-94f7f6470c74.png?v=1580414547"},{"product_id":"aemc-5050","title":"AEMC 5050 Digital Megohmmeter","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"111\" data-end=\"207\" class=\"\"\u003e\u003cstrong data-start=\"111\" data-end=\"207\"\u003eAEMC 5050 Digital Megohmmeter – Rugged 5kV Insulation Testing for Utility and Industrial Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"209\" data-end=\"618\" class=\"\"\u003eThe AEMC 5050 is a powerful and portable 5kV digital megohmmeter designed for insulation resistance testing up to 10TΩ. It delivers high-performance testing in the field, with features like real-time plotting, programmable test durations, and automatic DAR and PI calculations. Ideal for maintenance teams, electrical contractors, and utility crews who need reliable results from a rugged, field-ready device.\u003c\/p\u003e\n\u003cp data-start=\"620\" data-end=\"817\" class=\"\"\u003eWith an intuitive interface and large backlit display, the 5050 is simple to operate—even with gloves on. USB connectivity and included software allow easy data transfer and professional reporting.\u003c\/p\u003e\n\u003cp data-start=\"819\" data-end=\"839\" class=\"\"\u003e\u003cstrong data-start=\"819\" data-end=\"839\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"840\" data-end=\"999\"\u003e\n\u003cli data-start=\"840\" data-end=\"873\" class=\"\"\u003e\n\u003cp data-start=\"842\" data-end=\"873\" class=\"\"\u003eAEMC 5050 Digital Megohmmeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"874\" data-end=\"901\" class=\"\"\u003e\n\u003cp data-start=\"876\" data-end=\"901\" class=\"\"\u003eHigh-voltage test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"902\" data-end=\"919\" class=\"\"\u003e\n\u003cp data-start=\"904\" data-end=\"919\" class=\"\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"920\" data-end=\"956\" class=\"\"\u003e\n\u003cp data-start=\"922\" data-end=\"956\" class=\"\"\u003eRechargeable battery and charger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"983\" class=\"\"\u003e\n\u003cp data-start=\"959\" data-end=\"983\" class=\"\"\u003eUSB cable and software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"984\" data-end=\"999\" class=\"\"\u003e\n\u003cp data-start=\"986\" data-end=\"999\" class=\"\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1001\" data-end=\"1018\" class=\"\"\u003e\u003cstrong data-start=\"1001\" data-end=\"1018\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1019\" data-end=\"1353\"\u003e\n\u003cli data-start=\"1019\" data-end=\"1074\" class=\"\"\u003e\n\u003cp data-start=\"1021\" data-end=\"1074\" class=\"\"\u003eSelectable test voltages: 500V, 1000V, 2500V, 5000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1075\" data-end=\"1120\" class=\"\"\u003e\n\u003cp data-start=\"1077\" data-end=\"1120\" class=\"\"\u003eMeasures insulation resistance up to 10TΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1121\" data-end=\"1187\" class=\"\"\u003e\n\u003cp data-start=\"1123\" data-end=\"1187\" class=\"\"\u003eCalculates DAR, PI, DD (Dielectric Discharge), and capacitance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1242\" class=\"\"\u003e\n\u003cp data-start=\"1190\" data-end=\"1242\" class=\"\"\u003eReal-time plotting and programmable test sequences\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1243\" data-end=\"1284\" class=\"\"\u003e\n\u003cp data-start=\"1245\" data-end=\"1284\" class=\"\"\u003eBuilt-in voltmeter (AC\/DC) up to 700V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1324\" class=\"\"\u003e\n\u003cp data-start=\"1287\" data-end=\"1324\" class=\"\"\u003eRechargeable battery with long life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1325\" data-end=\"1353\" class=\"\"\u003e\n\u003cp data-start=\"1327\" data-end=\"1353\" class=\"\"\u003eCAT IV 600V safety rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1355\" data-end=\"1372\" class=\"\"\u003e\u003cstrong data-start=\"1355\" data-end=\"1372\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1373\" data-end=\"1608\"\u003e\n\u003cli data-start=\"1373\" data-end=\"1444\" class=\"\"\u003e\n\u003cp data-start=\"1375\" data-end=\"1444\" class=\"\"\u003eAcceptance and maintenance testing for cables, motors, transformers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1445\" data-end=\"1498\" class=\"\"\u003e\n\u003cp data-start=\"1447\" data-end=\"1498\" class=\"\"\u003eSubstation and switchgear insulation verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1499\" data-end=\"1529\" class=\"\"\u003e\n\u003cp data-start=\"1501\" data-end=\"1529\" class=\"\"\u003eHigh-voltage system audits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1530\" data-end=\"1562\" class=\"\"\u003e\n\u003cp data-start=\"1532\" data-end=\"1562\" class=\"\"\u003eIndustrial plant maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1563\" data-end=\"1608\" class=\"\"\u003e\n\u003cp data-start=\"1565\" data-end=\"1608\" class=\"\"\u003eService and predictive maintenance programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1610\" data-end=\"1972\" class=\"\"\u003e\u003cstrong data-start=\"1610\" data-end=\"1648\"\u003eWhy Order from Duncan Instruments?\u003c\/strong\u003e\u003cbr data-start=\"1648\" data-end=\"1651\"\u003eWe specialize in the calibration and repair of high-voltage testers like the AEMC 5050, serving electrical contractors and utilities across Canada. With prices automatically matched against major Canadian suppliers and expert support always available, you can count on Duncan Instruments for dependable service and value.\u003c\/p\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"3029\" data-start=\"1936\" style=\"width: 100%; height: 215.531px;\"\u003e\n\u003cthead data-end=\"2056\" data-start=\"1936\"\u003e\n\u003ctr data-end=\"2056\" data-start=\"1936\" style=\"height: 19.5938px;\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1969\" data-start=\"1936\" style=\"width: 21.6239%; height: 19.5938px;\"\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1996\" data-start=\"1969\" style=\"width: 24.0262%; height: 19.5938px;\"\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2025\" data-start=\"1996\" style=\"width: 27.6841%; height: 19.5938px;\"\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2056\" data-start=\"2025\" style=\"width: 21.6657%; height: 19.5938px;\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"3029\" data-start=\"2179\"\u003e\n\u003ctr data-end=\"2301\" data-start=\"2179\" style=\"height: 19.5938px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2212\" data-start=\"2179\" style=\"width: 21.6239%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2240\" data-start=\"2212\" style=\"width: 24.0262%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2270\" data-start=\"2240\" data-col-size=\"sm\" style=\"width: 27.6841%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2301\" data-start=\"2270\" data-col-size=\"sm\" style=\"width: 21.6657%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2424\" data-start=\"2302\" style=\"height: 39.1875px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2335\" data-start=\"2302\" style=\"width: 21.6239%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2363\" data-start=\"2335\" style=\"width: 24.0262%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2393\" data-start=\"2363\" style=\"width: 27.6841%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2424\" data-start=\"2393\" style=\"width: 21.6657%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2544\" data-start=\"2425\" style=\"height: 19.5938px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2458\" data-start=\"2425\" style=\"width: 21.6239%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2485\" data-start=\"2458\" style=\"width: 24.0262%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2514\" data-start=\"2485\" style=\"width: 27.6841%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2544\" data-start=\"2514\" data-col-size=\"sm\" style=\"width: 21.6657%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2667\" data-start=\"2545\" style=\"height: 19.5938px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2578\" data-start=\"2545\" style=\"width: 21.6239%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2606\" data-start=\"2578\" style=\"width: 24.0262%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2636\" data-start=\"2606\" data-col-size=\"sm\" style=\"width: 27.6841%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2667\" data-start=\"2636\" data-col-size=\"sm\" style=\"width: 21.6657%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2787\" data-start=\"2668\" style=\"height: 19.5938px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2701\" data-start=\"2668\" style=\"width: 21.6239%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2728\" data-start=\"2701\" style=\"width: 24.0262%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2757\" data-start=\"2728\" data-col-size=\"sm\" style=\"width: 27.6841%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2787\" data-start=\"2757\" data-col-size=\"sm\" style=\"width: 21.6657%; height: 19.5938px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2907\" data-start=\"2788\" style=\"height: 39.1875px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2821\" data-start=\"2788\" style=\"width: 21.6239%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2848\" data-start=\"2821\" data-col-size=\"sm\" style=\"width: 24.0262%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2877\" data-start=\"2848\" data-col-size=\"sm\" style=\"width: 27.6841%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2907\" data-start=\"2877\" data-col-size=\"sm\" style=\"width: 21.6657%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3029\" data-start=\"2908\" style=\"height: 39.1875px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2941\" data-start=\"2908\" style=\"width: 21.6239%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2969\" data-start=\"2941\" data-col-size=\"sm\" style=\"width: 24.0262%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"3001\" data-start=\"2969\" data-col-size=\"sm\" style=\"width: 27.6841%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"3029\" data-start=\"3001\" data-col-size=\"sm\" style=\"width: 21.6657%; height: 39.1875px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":31814753812577,"sku":"AEMC2130.20","price":4597.81,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/megohmmeter-2130-20.png?v=1581704694"},{"product_id":"aemc-5060","title":"AEMC 5060 Digital Megohmmeter","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"119\" data-end=\"226\" class=\"\"\u003e\u003cstrong data-start=\"119\" data-end=\"226\"\u003eAEMC 5060 Digital Megohmmeter – High-Voltage Insulation Testing with Graphical Display and Data Logging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"228\" data-end=\"552\" class=\"\"\u003eThe AEMC 5060 is a robust 5kV digital megohmmeter engineered for high-performance insulation testing in utility and industrial settings. With selectable test voltages from 500V to 5000V and a resistance range up to 10TΩ, the 5060 provides precision measurements along with advanced diagnostic functions like DAR, PI, and DD.\u003c\/p\u003e\n\u003cp data-start=\"554\" data-end=\"812\" class=\"\"\u003eIts large, dual-display screen includes an analog-style bargraph and digital readout, making it easy to monitor real-time test progress. The instrument stores up to 1,300 tests and comes with DataView® software for full PC connectivity and report generation.\u003c\/p\u003e\n\u003cp data-start=\"814\" data-end=\"834\" class=\"\"\u003e\u003cstrong data-start=\"814\" data-end=\"834\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"835\" data-end=\"1036\"\u003e\n\u003cli data-start=\"835\" data-end=\"868\" class=\"\"\u003e\n\u003cp data-start=\"837\" data-end=\"868\" class=\"\"\u003eAEMC 5060 Digital Megohmmeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"869\" data-end=\"906\" class=\"\"\u003e\n\u003cp data-start=\"871\" data-end=\"906\" class=\"\"\u003eHigh-voltage test leads and clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"907\" data-end=\"924\" class=\"\"\u003e\n\u003cp data-start=\"909\" data-end=\"924\" class=\"\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"925\" data-end=\"961\" class=\"\"\u003e\n\u003cp data-start=\"927\" data-end=\"961\" class=\"\"\u003eRechargeable battery and charger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"962\" data-end=\"998\" class=\"\"\u003e\n\u003cp data-start=\"964\" data-end=\"998\" class=\"\"\u003eUSB cable and DataView® software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1036\" class=\"\"\u003e\n\u003cp data-start=\"1001\" data-end=\"1036\" class=\"\"\u003eUser manual and quick-start guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1038\" data-end=\"1055\" class=\"\"\u003e\u003cstrong data-start=\"1038\" data-end=\"1055\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1056\" data-end=\"1421\"\u003e\n\u003cli data-start=\"1056\" data-end=\"1100\" class=\"\"\u003e\n\u003cp data-start=\"1058\" data-end=\"1100\" class=\"\"\u003eTest voltages: 500V, 1000V, 2500V, 5000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1101\" data-end=\"1137\" class=\"\"\u003e\n\u003cp data-start=\"1103\" data-end=\"1137\" class=\"\"\u003eInsulation resistance up to 10TΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1138\" data-end=\"1181\" class=\"\"\u003e\n\u003cp data-start=\"1140\" data-end=\"1181\" class=\"\"\u003eCalculates PI, DAR, DD, and capacitance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1182\" data-end=\"1225\" class=\"\"\u003e\n\u003cp data-start=\"1184\" data-end=\"1225\" class=\"\"\u003eDual display: digital + analog bargraph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1226\" data-end=\"1261\" class=\"\"\u003e\n\u003cp data-start=\"1228\" data-end=\"1261\" class=\"\"\u003eStores up to 1,300 test results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1262\" data-end=\"1312\" class=\"\"\u003e\n\u003cp data-start=\"1264\" data-end=\"1312\" class=\"\"\u003eUSB interface with included DataView® software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1313\" data-end=\"1343\" class=\"\"\u003e\n\u003cp data-start=\"1315\" data-end=\"1343\" class=\"\"\u003eAC\/DC voltmeter up to 700V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1344\" data-end=\"1372\" class=\"\"\u003e\n\u003cp data-start=\"1346\" data-end=\"1372\" class=\"\"\u003eCAT IV 600V safety rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1373\" data-end=\"1421\" class=\"\"\u003e\n\u003cp data-start=\"1375\" data-end=\"1421\" class=\"\"\u003eRugged and field-ready with rechargeable power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1423\" data-end=\"1440\" class=\"\"\u003e\u003cstrong data-start=\"1423\" data-end=\"1440\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1441\" data-end=\"1696\"\u003e\n\u003cli data-start=\"1441\" data-end=\"1495\" class=\"\"\u003e\n\u003cp data-start=\"1443\" data-end=\"1495\" class=\"\"\u003eHigh-voltage equipment maintenance and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1555\" class=\"\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1555\" class=\"\"\u003eAcceptance testing for motors, cables, and transformers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1556\" data-end=\"1611\" class=\"\"\u003e\n\u003cp data-start=\"1558\" data-end=\"1611\" class=\"\"\u003eUtilities, substations, and electrical distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1612\" data-end=\"1662\" class=\"\"\u003e\n\u003cp data-start=\"1614\" data-end=\"1662\" class=\"\"\u003ePredictive and preventive maintenance programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1663\" data-end=\"1696\" class=\"\"\u003e\n\u003cp data-start=\"1665\" data-end=\"1696\" class=\"\"\u003eCommissioning and system audits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1698\" data-end=\"2010\" class=\"\"\u003e\u003cstrong data-start=\"1698\" data-end=\"1736\"\u003eWhy Order from Duncan Instruments?\u003c\/strong\u003e\u003cbr data-start=\"1736\" data-end=\"1739\"\u003eWe calibrate and service AEMC 5060 megohmmeters for utility companies and electrical contractors across Canada. Our prices are auto-compared daily with Canadian competitors, and our knowledgeable team is here to support you with expert advice and fast turnaround service.\u003c\/p\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":31814777995361,"sku":"AEMC2130.21","price":5124.36,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/megohmmeter-2130-21.png?v=1581705816"},{"product_id":"aemc-6505","title":"AEMC 6505 Digital Megohmmeter","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"110\" data-end=\"204\" class=\"\"\u003e\u003cstrong data-start=\"110\" data-end=\"204\"\u003eAEMC 6505 Digital Megohmmeter – High-Voltage Insulation Testing for Demanding Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"206\" data-end=\"564\" class=\"\"\u003eThe AEMC 6505 is a heavy-duty, high-voltage digital megohmmeter designed for advanced insulation resistance testing in industrial and utility environments. With selectable test voltages up to 5000V and insulation resistance measurements up to 10TΩ (10,000GΩ), it’s built for high-performance testing of motors, cables, switchgear, and other critical systems.\u003c\/p\u003e\n\u003cp data-start=\"566\" data-end=\"909\" class=\"\"\u003eThis instrument offers timed tests, temperature compensation, step voltage, and dielectric absorption ratio (DAR) and polarization index (PI) calculations—all with results viewable on a large dual-display LCD. Whether you're troubleshooting or conducting scheduled maintenance, the 6505 delivers laboratory-grade accuracy in a portable format.\u003c\/p\u003e\n\u003cp data-start=\"911\" data-end=\"931\" class=\"\"\u003e\u003cstrong data-start=\"911\" data-end=\"931\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"932\" data-end=\"1093\"\u003e\n\u003cli data-start=\"932\" data-end=\"965\" class=\"\"\u003e\n\u003cp data-start=\"934\" data-end=\"965\" class=\"\"\u003eAEMC 6505 Digital Megohmmeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"966\" data-end=\"1000\" class=\"\"\u003e\n\u003cp data-start=\"968\" data-end=\"1000\" class=\"\"\u003eSet of high-voltage test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1001\" data-end=\"1018\" class=\"\"\u003e\n\u003cp data-start=\"1003\" data-end=\"1018\" class=\"\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1019\" data-end=\"1055\" class=\"\"\u003e\n\u003cp data-start=\"1021\" data-end=\"1055\" class=\"\"\u003eRechargeable battery and charger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1056\" data-end=\"1093\" class=\"\"\u003e\n\u003cp data-start=\"1058\" data-end=\"1093\" class=\"\"\u003eUser manual and quick-start guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1095\" data-end=\"1112\" class=\"\"\u003e\u003cstrong data-start=\"1095\" data-end=\"1112\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1113\" data-end=\"1458\"\u003e\n\u003cli data-start=\"1113\" data-end=\"1210\" class=\"\"\u003e\n\u003cp data-start=\"1115\" data-end=\"1210\" class=\"\"\u003eInsulation resistance up to 10TΩ with selectable test voltages: 500V, 1000V, 2500V, and 5000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1211\" data-end=\"1265\" class=\"\"\u003e\n\u003cp data-start=\"1213\" data-end=\"1265\" class=\"\"\u003eTimed testing, PI, DAR, and temperature correction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1266\" data-end=\"1314\" class=\"\"\u003e\n\u003cp data-start=\"1268\" data-end=\"1314\" class=\"\"\u003eLarge dual-display LCD with real-time graphs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1315\" data-end=\"1346\" class=\"\"\u003e\n\u003cp data-start=\"1317\" data-end=\"1346\" class=\"\"\u003eRechargeable battery system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1347\" data-end=\"1379\" class=\"\"\u003e\n\u003cp data-start=\"1349\" data-end=\"1379\" class=\"\"\u003eUSB output for data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1380\" data-end=\"1411\" class=\"\"\u003e\n\u003cp data-start=\"1382\" data-end=\"1411\" class=\"\"\u003eSafety rated to CAT IV 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1412\" data-end=\"1458\" class=\"\"\u003e\n\u003cp data-start=\"1414\" data-end=\"1458\" class=\"\"\u003eRugged case for demanding field conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1460\" data-end=\"1477\" class=\"\"\u003e\u003cstrong data-start=\"1460\" data-end=\"1477\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1478\" data-end=\"1734\"\u003e\n\u003cli data-start=\"1478\" data-end=\"1549\" class=\"\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1549\" class=\"\"\u003eAcceptance and maintenance testing of electrical rotating machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1550\" data-end=\"1606\" class=\"\"\u003e\n\u003cp data-start=\"1552\" data-end=\"1606\" class=\"\"\u003eHigh-voltage cable and transformer insulation checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1607\" data-end=\"1639\" class=\"\"\u003e\n\u003cp data-start=\"1609\" data-end=\"1639\" class=\"\"\u003eSubstation equipment testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1640\" data-end=\"1681\" class=\"\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1681\" class=\"\"\u003ePredictive and preventive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1682\" data-end=\"1734\" class=\"\"\u003e\n\u003cp data-start=\"1684\" data-end=\"1734\" class=\"\"\u003eUtilities, heavy industry, and service contractors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1736\" data-end=\"2075\" class=\"\"\u003e\u003cstrong data-start=\"1736\" data-end=\"1774\"\u003eWhy Order from Duncan Instruments?\u003c\/strong\u003e\u003cbr data-start=\"1774\" data-end=\"1777\"\u003eWe repair and calibrate high-voltage insulation testers like the AEMC 6505 for utility and electrical professionals across Canada. With daily price matching against Canadian competitors and trusted service expertise, Duncan Instruments is your reliable partner in electrical safety and diagnostics.\u003c\/p\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"3199\" data-start=\"2109\"\u003e\n\u003cthead data-end=\"2228\" data-start=\"2109\"\u003e\n\u003ctr data-end=\"2228\" data-start=\"2109\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2142\" data-start=\"2109\"\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2168\" data-start=\"2142\"\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2197\" data-start=\"2168\"\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"2228\" data-start=\"2197\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"3199\" data-start=\"2351\"\u003e\n\u003ctr data-end=\"2473\" data-start=\"2351\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2384\" data-start=\"2351\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2411\" data-start=\"2384\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2441\" data-start=\"2411\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2473\" data-start=\"2441\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2596\" data-start=\"2474\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2507\" data-start=\"2474\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2534\" data-start=\"2507\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2564\" data-start=\"2534\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2596\" data-start=\"2564\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2716\" data-start=\"2597\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2630\" data-start=\"2597\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2656\" data-start=\"2630\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2685\" data-start=\"2656\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2716\" data-start=\"2685\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2838\" data-start=\"2717\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2750\" data-start=\"2717\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2777\" data-start=\"2750\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2807\" data-start=\"2777\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2838\" data-start=\"2807\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2958\" data-start=\"2839\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2872\" data-start=\"2839\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2898\" data-start=\"2872\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2927\" data-start=\"2898\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2958\" data-start=\"2927\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3078\" data-start=\"2959\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2992\" data-start=\"2959\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"3018\" data-start=\"2992\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"3047\" data-start=\"3018\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"3078\" data-start=\"3047\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3199\" data-start=\"3079\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3112\" data-start=\"3079\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3141\" data-start=\"3112\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3168\" data-start=\"3141\"\u003e\u003c\/td\u003e\n\u003ctd data-end=\"3199\" data-start=\"3168\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":31814945800289,"sku":"AEMC2130.18","price":3968.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/megohmmeter-2130-18_1376c834-c9fd-4f41-b856-3c1e88ac0f9e.png?v=1581711291"},{"product_id":"aemc-6527-digital-megohmmeter-with-continuity-4000-ω","title":"AEMC 6527 Digital Megohmmeter – Compact Insulation and Continuity Testing in One","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"213\" data-end=\"583\" class=\"\"\u003eThe AEMC 6527 is a handheld digital megohmmeter designed for insulation resistance testing up to 4000MΩ and continuity measurements down to 0.1Ω. With selectable test voltages (250V, 500V, and 1000V) and a built-in voltmeter up to 600V, it’s an ideal tool for field technicians and electrical contractors working on residential, commercial, and industrial installations.\u003c\/p\u003e\n\u003cp data-start=\"585\" data-end=\"818\" class=\"\"\u003eLightweight, rugged, and easy to operate, the 6527 is a solid choice for troubleshooting and preventive maintenance. Its backlit display, auto-hold function, and intuitive layout make it easy to use even in low-light or tight spaces.\u003c\/p\u003e\n\u003cp data-start=\"820\" data-end=\"840\" class=\"\"\u003e\u003cstrong data-start=\"820\" data-end=\"840\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"841\" data-end=\"970\"\u003e\n\u003cli data-start=\"841\" data-end=\"874\" class=\"\"\u003e\n\u003cp data-start=\"843\" data-end=\"874\" class=\"\"\u003eAEMC 6527 Digital Megohmmeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"875\" data-end=\"909\" class=\"\"\u003e\n\u003cp data-start=\"877\" data-end=\"909\" class=\"\"\u003eTest leads and alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"910\" data-end=\"928\" class=\"\"\u003e\n\u003cp data-start=\"912\" data-end=\"928\" class=\"\"\u003eCarrying pouch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"929\" data-end=\"954\" class=\"\"\u003e\n\u003cp data-start=\"931\" data-end=\"954\" class=\"\"\u003eBatteries (installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"955\" data-end=\"970\" class=\"\"\u003e\n\u003cp data-start=\"957\" data-end=\"970\" class=\"\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"972\" data-end=\"989\" class=\"\"\u003e\u003cstrong data-start=\"972\" data-end=\"989\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"990\" data-end=\"1317\"\u003e\n\u003cli data-start=\"990\" data-end=\"1052\" class=\"\"\u003e\n\u003cp data-start=\"992\" data-end=\"1052\" class=\"\"\u003eInsulation resistance up to 4000MΩ at 250V, 500V, or 1000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1053\" data-end=\"1106\" class=\"\"\u003e\n\u003cp data-start=\"1055\" data-end=\"1106\" class=\"\"\u003eContinuity testing with audible beep down to 0.1Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1107\" data-end=\"1148\" class=\"\"\u003e\n\u003cp data-start=\"1109\" data-end=\"1148\" class=\"\"\u003eBuilt-in voltmeter (AC\/DC) up to 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1149\" data-end=\"1213\" class=\"\"\u003e\n\u003cp data-start=\"1151\" data-end=\"1213\" class=\"\"\u003eAuto-hold, auto-off, and data storage for up to 300 readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1214\" data-end=\"1249\" class=\"\"\u003e\n\u003cp data-start=\"1216\" data-end=\"1249\" class=\"\"\u003eLarge, easy-to-read backlit LCD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1250\" data-end=\"1286\" class=\"\"\u003e\n\u003cp data-start=\"1252\" data-end=\"1286\" class=\"\"\u003eCompact and rugged for field use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1287\" data-end=\"1317\" class=\"\"\u003e\n\u003cp data-start=\"1289\" data-end=\"1317\" class=\"\"\u003eSafety rated to 600V CAT III\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1319\" data-end=\"1336\" class=\"\"\u003e\u003cstrong data-start=\"1319\" data-end=\"1336\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1337\" data-end=\"1556\"\u003e\n\u003cli data-start=\"1337\" data-end=\"1391\" class=\"\"\u003e\n\u003cp data-start=\"1339\" data-end=\"1391\" class=\"\"\u003eInsulation checks on motors, cables, and equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1392\" data-end=\"1441\" class=\"\"\u003e\n\u003cp data-start=\"1394\" data-end=\"1441\" class=\"\"\u003eElectrical maintenance and safety inspections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1442\" data-end=\"1485\" class=\"\"\u003e\n\u003cp data-start=\"1444\" data-end=\"1485\" class=\"\"\u003eGround bond and continuity verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1486\" data-end=\"1556\" class=\"\"\u003e\n\u003cp data-start=\"1488\" data-end=\"1556\" class=\"\"\u003eCommissioning and troubleshooting of low- and medium-voltage systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1558\" data-end=\"1890\" class=\"\"\u003e\u003cstrong data-start=\"1558\" data-end=\"1596\"\u003eWhy Order from Duncan Instruments?\u003c\/strong\u003e\u003cbr data-start=\"1596\" data-end=\"1599\"\u003eWe don’t just sell AEMC insulation testers—we repair and calibrate them for electrical professionals and utilities across Canada. Our pricing is automatically compared with top Canadian distributors, and our team is ready to help you choose, maintain, and get the most out of your equipment.\u003c\/p\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":31814959956065,"sku":"AEMC2126.53","price":394.25,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/AEMC_6527.jpg?v=1581711961"},{"product_id":"aemc-6550","title":"AEMC 6550 Graphical 10kV Megohmmeter","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"159\" data-end=\"273\" class=\"\"\u003e\u003cstrong data-start=\"159\" data-end=\"273\"\u003eAEMC 6550 Graphical 10kV Megohmmeter – High-Voltage Insulation Testing with DataView® and Advanced Diagnostics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"275\" data-end=\"582\" class=\"\"\u003eThe AEMC 6550 is a heavy-duty 10kV digital megohmmeter engineered for demanding insulation testing in high-voltage industrial and utility environments. It offers advanced diagnostic capabilities such as DAR, PI, DD, and Step Voltage testing, all displayed in real time on a large, backlit graphical screen.\u003c\/p\u003e\n\u003cp data-start=\"584\" data-end=\"899\" class=\"\"\u003eWith an insulation resistance range up to 10TΩ, the 6550 is ideal for verifying insulation integrity on transformers, cables, switchgear, and rotating machinery. It stores over 1,300 test results and comes with AEMC’s powerful DataView® software for streamlined data transfer, trend analysis, and report generation.\u003c\/p\u003e\n\u003cp data-start=\"901\" data-end=\"921\" class=\"\"\u003e\u003cstrong data-start=\"901\" data-end=\"921\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"922\" data-end=\"1120\"\u003e\n\u003cli data-start=\"922\" data-end=\"962\" class=\"\"\u003e\n\u003cp data-start=\"924\" data-end=\"962\" class=\"\"\u003eAEMC 6550 10kV Graphical Megohmmeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"963\" data-end=\"990\" class=\"\"\u003e\n\u003cp data-start=\"965\" data-end=\"990\" class=\"\"\u003eHigh-voltage test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"991\" data-end=\"1008\" class=\"\"\u003e\n\u003cp data-start=\"993\" data-end=\"1008\" class=\"\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1009\" data-end=\"1045\" class=\"\"\u003e\n\u003cp data-start=\"1011\" data-end=\"1045\" class=\"\"\u003eRechargeable battery and charger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1046\" data-end=\"1082\" class=\"\"\u003e\n\u003cp data-start=\"1048\" data-end=\"1082\" class=\"\"\u003eUSB cable and DataView® software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1083\" data-end=\"1120\" class=\"\"\u003e\n\u003cp data-start=\"1085\" data-end=\"1120\" class=\"\"\u003eUser manual and quick-start guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1122\" data-end=\"1139\" class=\"\"\u003e\u003cstrong data-start=\"1122\" data-end=\"1139\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1140\" data-end=\"1598\"\u003e\n\u003cli data-start=\"1140\" data-end=\"1205\" class=\"\"\u003e\n\u003cp data-start=\"1142\" data-end=\"1205\" class=\"\"\u003eTest voltages from 40V to 10,000V (programmable in 10V steps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1206\" data-end=\"1251\" class=\"\"\u003e\n\u003cp data-start=\"1208\" data-end=\"1251\" class=\"\"\u003eMeasures insulation resistance up to 10TΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1252\" data-end=\"1308\" class=\"\"\u003e\n\u003cp data-start=\"1254\" data-end=\"1308\" class=\"\"\u003eCalculates PI, DAR, DD, Step Voltage, and Ramp tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1309\" data-end=\"1360\" class=\"\"\u003e\n\u003cp data-start=\"1311\" data-end=\"1360\" class=\"\"\u003eBuilt-in voltmeter for AC\/DC voltage up to 700V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1361\" data-end=\"1414\" class=\"\"\u003e\n\u003cp data-start=\"1363\" data-end=\"1414\" class=\"\"\u003eStores over 1,300 test results in internal memory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1415\" data-end=\"1480\" class=\"\"\u003e\n\u003cp data-start=\"1417\" data-end=\"1480\" class=\"\"\u003eGraphical LCD displays test progress and results in real time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1481\" data-end=\"1538\" class=\"\"\u003e\n\u003cp data-start=\"1483\" data-end=\"1538\" class=\"\"\u003eDataView® software for PC data analysis and reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1539\" data-end=\"1598\" class=\"\"\u003e\n\u003cp data-start=\"1541\" data-end=\"1598\" class=\"\"\u003eRugged, field-ready case with CAT IV 600V safety rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1600\" data-end=\"1617\" class=\"\"\u003e\u003cstrong data-start=\"1600\" data-end=\"1617\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1618\" data-end=\"1833\"\u003e\n\u003cli data-start=\"1618\" data-end=\"1673\" class=\"\"\u003e\n\u003cp data-start=\"1620\" data-end=\"1673\" class=\"\"\u003eHigh-voltage motor and generator insulation testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1674\" data-end=\"1711\" class=\"\"\u003e\n\u003cp data-start=\"1676\" data-end=\"1711\" class=\"\"\u003eTransformer and cable diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1712\" data-end=\"1756\" class=\"\"\u003e\n\u003cp data-start=\"1714\" data-end=\"1756\" class=\"\"\u003eSubstation maintenance and commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1757\" data-end=\"1799\" class=\"\"\u003e\n\u003cp data-start=\"1759\" data-end=\"1799\" class=\"\"\u003eUtilities, industrial plants, and OEMs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1800\" data-end=\"1833\" class=\"\"\u003e\n\u003cp data-start=\"1802\" data-end=\"1833\" class=\"\"\u003ePredictive maintenance programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1835\" data-end=\"2247\" class=\"\"\u003e\u003cstrong data-start=\"1835\" data-end=\"1873\"\u003eWhy Order from Duncan Instruments?\u003c\/strong\u003e\u003cbr data-start=\"1873\" data-end=\"1876\"\u003eWe calibrate and repair high-voltage insulation testers like the AEMC 6550 for utility companies and industrial maintenance teams across Canada. Our pricing is automatically updated against Canadian competitors, and our in-house team is here to support your equipment before and after the sale.\u003c\/p\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":31814984892513,"sku":"AEMC2130.31","price":9085.38,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/megohmmeter-2130-31.png?v=1581712755"},{"product_id":"fluke-1577-insulation-multimeter","title":"Fluke 1577 Insulation Multimeter","description":"\u003ch3\u003e\u003cstrong\u003eCompare with:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/duncaninstr.com\/collections\/insulation-tester\/products\/metrel-md-9070-insulation-continuity-digital-multimeter\"\u003e\u003cstrong\u003eMETREL MD 9070\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/duncaninstr.com\/collections\/insulation-tester\/products\/metrel-mi-3121-insulation-continuity-tester\"\u003e\u003cstrong\u003eMETREL MI 3121\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis insulation multimeter comes in a compact and handheld design, which enables maximum versatility for both troubleshooting and preventative maintenance. Additionally, this product is also rugged, reliable, and easy to use.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuto discharge of capacitive voltage\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage\u003c\/li\u003e\n\u003cli\u003eDC millivolts\u003c\/li\u003e\n\u003cli\u003eAC\/DC milliamps\u003c\/li\u003e\n\u003cli\u003eContinuity\u003c\/li\u003e\n\u003cli\u003eAuto power off to save battery power\u003c\/li\u003e\n\u003cli\u003eTrue RMS\u003c\/li\u003e\n\u003cli\u003eLarge display with backlight\u003c\/li\u003e\n\u003cli\u003eLive circuit detection prevents insulation test if voltage \u0026lt;30 V is detected for added user protection\u003c\/li\u003e\n\u003cli\u003eCAT III 1000V, CAT IV 600V measurement category\u003c\/li\u003e\n\u003cli\u003eAccepts magnetic hanging system to free your hands for other work (sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTroubleshooting\u003c\/li\u003e\n\u003cli\u003ePreventative maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFluke 1577 Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Amps\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Amps\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(2.0% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistance\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Test Current at 1 kΩ\/V\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistance per Test Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003cbr\u003e100 V\u003cbr\u003e250 V\u003cbr\u003e500 V\u003cbr\u003e1000 V: 600 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution per Test Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V: 0.01 MΩ\u003cbr\u003e100 V: 0.01 MΩ\u003cbr\u003e250 V: 0.1 MΩ\u003cbr\u003e500 V: 0.1 MΩ\u003cbr\u003e1000 V: 0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy per Test Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V: ±(3% + 5)\u003cbr\u003e100 V: ±(3% + 5)\u003cbr\u003e250 V: ±(1.5% + 5)\u003cbr\u003e500 V: ±(2.0% + 5)\u003cbr\u003e1000 V: ±(2.0% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 131°F (–20 to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (Without Condensation)\u003c\/td\u003e\n\u003ctd\u003e0 to 95%: 50 to 86°F (10 to 30°C)\u003cbr\u003e0 to 75%: 86 to 104°F (30 to 40°C)\u003cbr\u003e0 to 40%: 104 to 131°F (40 to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e6561.68' (2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical and General Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life Alkaline\u003c\/td\u003e\n\u003ctd\u003eMeter use: 1000 hours\u003cbr\u003eInsulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.99 x 3.94 x 1.97\" (203 x 100 x 50 mm) (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22 oz (624 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSafety Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eWhat's included with the Fluke 1577\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMultimeter\u003c\/li\u003e\n\u003cli\u003eRemote Probe\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eUser Documentation\u003c\/li\u003e\n\u003cli\u003eThree-Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":31851018584161,"sku":"FLUKE-1577","price":1388.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/F-1577_01a_h.png?v=1582644936"},{"product_id":"fluke-1550c-digital-insulation-resistance-tester-5kv","title":"Fluke 1550C Digital Insulation Resistance Tester, 5kV","description":"\u003cp\u003e\u003cstrong\u003eIdeal for preventive or predictive maintenance programs, this insulation resistance tester identifies potential equipment failures before they occur. This tool is Fluke Connect compatible tests digital insulation up to 5 kV. Additionally, remote operation enables you to spend less time in potentially hazardous areas.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvaluate the trends, eliminate the doubt\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTest up to 5 kV and makes data collection easy due to its compatibility with the Fluke Connect™ wireless application. This insulation meter is ideal for testing a wide range of high voltage equipment including switchgear, motors, generators, and cables.\u003c\/p\u003e\n\u003cp\u003eConduct the entire range of test voltages specified in IEEE 43-2000 with a best in class and CAT IV 600 V safety rating. With measurement storage and PC interface, it is ideal for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuickly configure, start, and stop tests remotely, a safe distance away from any operating, energized equipment, using Fluke Connect® and a smartphone\u003c\/li\u003e\n\u003cli\u003eReal time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh voltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance programs\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFluke 1550C Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 250 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 kΩ\u003cbr\u003e250 kΩ to 5 GΩ\u003cbr\u003e5 to 50 GΩ\u003cbr\u003e\u0026gt;50 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 500 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500 kΩ\u003cbr\u003e500 kΩ to 10 GΩ\u003cbr\u003e10 to 100 GΩ\u003cbr\u003e\u0026gt;100 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 1000 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 MΩ\u003cbr\u003e1 MΩ to 20 GΩ\u003cbr\u003e20 to 200 GΩ\u003cbr\u003e\u0026gt;200 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 2500 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2.5 MΩ\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cbr\u003e50 to 500 GΩ\u003cbr\u003e\u0026gt;500 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 5000 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 MΩ\u003cbr\u003e5 MΩ to 100 GΩ\u003cbr\u003e100GΩ to 1 TΩ\u003cbr\u003e\u0026gt;1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Resistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Graph Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e-0%, +10% at 1 mA load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInduced AC Mains Current Rejection\u003c\/td\u003e\n\u003ctd\u003e2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd\u003e5 seconds per µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd\u003e1.5 s\/µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current Measurement\u003c\/td\u003e\n\u003ctd\u003eRange: 1 nA to 2 mA\u003cbr\u003eAccuracy: ±(5% + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd\u003eRange: 0.01 to 15.00 µF\u003cbr\u003eAccuracy: ±(15% rdg + 0.03 µF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003eRange: 0 to 99 minutes\u003cbr\u003eResolution setting: 1 minute\u003cbr\u003eResolution Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive Circuit Warning\u003c\/td\u003e\n\u003ctd\u003eWarning range: 30 to 660 V AC\/DC, 50\/60 Hz\u003cbr\u003eVoltage accuracy: ±(15% + 2 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Specifications\u003c\/td\u003e\n\u003ctd\u003eFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2.95 x 4.13\" (75 x 105 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e12 V lead-acid rechargeable battery, Yuasa NP2.8-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger Input (AC)\u003c\/td\u003e\n\u003ctd\u003e85 to 250 V AC 50\/60 Hz 20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F (-20 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 149°F (-20 to 65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e80% to 88°F (31°C) decreasing linearly to 50% at 122°F (50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e6561.7' (2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Sealing\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Overload Protection\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility\u003c\/td\u003e\n\u003ctd\u003eEN 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.6 x 10.9 x 6.3\" (269 x 277 x 160 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.2 lbs (3.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eWhat's included with the Fluke 1550C\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared Adapter with Interface Cable\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eEnglish Manual\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick Reference Card\u003c\/li\u003e\n\u003cli\u003eSoftware License Agreement\u003c\/li\u003e\n\u003cli\u003eRegistration Card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":31851226988641,"sku":"FLUKE1550C","price":6500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/fluke_1550c.jpg?v=1582650104"},{"product_id":"fluke-1555-kit-insulation-resistance-tester-kit-10kv","title":"Fluke 1555\/KIT Insulation Resistance Tester Kit, 10kV","description":"\u003cp\u003e\u003cstrong\u003eVoltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600V AC or DC for increased user safety. With selectable test voltages in 50V steps from 250 to 1000V and 100V steps above 1000V. Complete kit including test cable set.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V\/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. Add this instrument to your preventive or predictive maintenance programs to identify potential equipment failures before they occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user-defined label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Automation\u003c\/li\u003e\n\u003cli\u003eCommercial\u003c\/li\u003e\n\u003cli\u003eDefense\u003c\/li\u003e\n\u003cli\u003eMilitary and Aerospace\u003c\/li\u003e\n\u003cli\u003eHVAC\/R\u003c\/li\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eMaintenance and Repair\u003c\/li\u003e\n\u003cli\u003eMining\u003c\/li\u003e\n\u003cli\u003eOil and Gas\u003c\/li\u003e\n\u003cli\u003eMotor Drive and Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cbr\u003e250 kΩ to 5 GΩ\u003cbr\u003e5 GΩ to 50 GΩ\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cbr\u003e500 kΩ to 10 GΩ\u003cbr\u003e10 GΩ to 100 GΩ\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cbr\u003e1 MΩ to 20 GΩ\u003cbr\u003e20 GΩ to 200 GΩ\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cbr\u003e50 GΩ to 500 GΩ\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cbr\u003e5 MΩ to 100 GΩ\u003cbr\u003e100 GΩ to 1 TΩ\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MΩ\u003cbr\u003e10 MΩ to 200 GΩ\u003cbr\u003e10 GΩ to 2 TΩ\u003cbr\u003e\u0026gt; 2 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eResolution Setting: 1 minute Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLive Circuit Warning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWarning Range 30 V to 660 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVoltage Accuracy ± (15 % + 2 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eAdditional\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Graph Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltage Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-0 %, +10 % at 1 mA load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInduced AC Mains Current Rejection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 seconds per °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 s\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eWhat's included with the Fluke 1555\/KIT\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eCertificate of Calibration\u003c\/li\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eEnglish manual\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick reference card\u003c\/li\u003e\n\u003cli\u003eSoftware license agreement\u003c\/li\u003e\n\u003cli\u003eRegistration card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003cli\u003eHeavy duty alligator clip leads\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":31851326963809,"sku":"Fluke1555-lit","price":7800.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/fluke-fluke-1555-kit.jpg?v=1582651465"},{"product_id":"fluke-1550c-kit-insulation-resistance-tester-kit-5-kv","title":"Fluke 1550C\/KIT Insulation Resistance Tester Kit, 5 kV","description":"\u003cp\u003e\u003cstrong\u003eIdeal for preventive or predictive maintenance programs, this insulation resistance tester identifies potential equipment failures before they occur. This tool is Fluke Connect compatible tests digital insulation up to 5 kV. Additionally, it comes equipped with a certificate of calibration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvaluate the trends, eliminate the doubt\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTest up to 5 kV and makes data collection easy due to its compatibility with the Fluke Connect™ wireless application. This insulation meter is ideal for testing a wide range of high voltage equipment including switchgear, motors, generators, and cables.\u003c\/p\u003e\n\u003cp\u003eConduct the entire range of test voltages specified in IEEE 43-2000 with a best in class and CAT IV 600 V safety rating. With measurement storage and PC interface, it is ideal for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuickly configure, start, and stop tests remotely, a safe distance away from any operating, energized equipment, using Fluke Connect® and a smartphone\u003c\/li\u003e\n\u003cli\u003eReal time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh voltage\u003c\/li\u003e\n\u003cli\u003ePreventive maintenance programs\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFluke 1550C\/KIT Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 250 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 kΩ\u003cbr\u003e250 kΩ to 5 GΩ\u003cbr\u003e5 to 50 GΩ\u003cbr\u003e\u0026gt;50 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 500 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500 kΩ\u003cbr\u003e500 kΩ to 10 GΩ\u003cbr\u003e10 to 100 GΩ\u003cbr\u003e\u0026gt;100 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 1000 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 MΩ\u003cbr\u003e1 MΩ to 20 GΩ\u003cbr\u003e20 to 200 GΩ\u003cbr\u003e\u0026gt;200 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 2500 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2.5 MΩ\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cbr\u003e50 to 500 GΩ\u003cbr\u003e\u0026gt;500 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTest Voltage (DC) 5000 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 MΩ\u003cbr\u003e5 MΩ to 100 GΩ\u003cbr\u003e100GΩ to 1 TΩ\u003cbr\u003e\u0026gt;1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (± Reading)\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Resistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Graph Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e-0%, +10% at 1 mA load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInduced AC Mains Current Rejection\u003c\/td\u003e\n\u003ctd\u003e2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd\u003e5 seconds per µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd\u003e1.5 s\/µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current Measurement\u003c\/td\u003e\n\u003ctd\u003eRange: 1 nA to 2 mA\u003cbr\u003eAccuracy: ±(5% + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd\u003eRange: 0.01 to 15.00 µF\u003cbr\u003eAccuracy: ±(15% rdg + 0.03 µF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003eRange: 0 to 99 minutes\u003cbr\u003eResolution setting: 1 minute\u003cbr\u003eResolution Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive Circuit Warning\u003c\/td\u003e\n\u003ctd\u003eWarning range: 30 to 660 V AC\/DC, 50\/60 Hz\u003cbr\u003eVoltage accuracy: ±(15% + 2 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Specifications\u003c\/td\u003e\n\u003ctd\u003eFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2.95 x 4.13\" (75 x 105 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e12 V lead-acid rechargeable battery, Yuasa NP2.8-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger Input (AC)\u003c\/td\u003e\n\u003ctd\u003e85 to 250 V AC 50\/60 Hz 20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F (-20 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 149°F (-20 to 65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e80% to 88°F (31°C) decreasing linearly to 50% at 122°F (50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e6561.7' (2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Sealing\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Overload Protection\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility\u003c\/td\u003e\n\u003ctd\u003eEN 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.6 x 10.9 x 6.3\" (269 x 277 x 160 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.2 lbs (3.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eWhat's included with the Fluke 1550C\/KIT\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eCertificate of Calibration\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared Adapter with Interface Cable\u003c\/li\u003e\n\u003cli\u003eHeavy Duty Alligator Clip Leads\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eEnglish Manual\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick Reference Card\u003c\/li\u003e\n\u003cli\u003eSoftware License Agreement\u003c\/li\u003e\n\u003cli\u003eRegistration Card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":31851504173153,"sku":"Fluke1550C-KIT","price":8859.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/unnamed_245062e2-916d-4725-8c77-636d125d12a1.jpg?v=1582652221"},{"product_id":"fluke-1555-fc-w-ir3000fc-10-kv-insulation-tester-with-ir3000-fc-connector","title":"Fluke 1555 FC w\/IR3000FC 10 kV Insulation Tester with IR3000 FC Connector","description":"\u003cp\u003e\u003cstrong\u003eThe Fluke 1555C Tester together with the IR3000 FC connector and Fluke Connect App allow users to perform advanced insulation testing by wirelessly transfering test results from the tester to Fluke Connect which eliminates error-prone paperwork and saves your technician's time.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis insulation resistance tester offers digital insulation testing up to 10 kV, making it ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables. It can conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, it is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen combined with the ir3000FC1550 Connector and Fluke Connect, it provides three unique benefits that increase work efficiency and safety:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time trending – show a graph of current insulation test data on your phone, rather than trying to interpret a hard-to-read set of changing numbers on the tester itself. Makes it easy to see if your test values are shifting in the right direction. You no longer need to import values into a separate spreadsheet\u003c\/li\u003e\n\u003cli\u003eRemote configuration and operation of your tester – take full control of your tester through your smartphone. Remote start and stop allows the user to move out of potentially hazardous zones before engaging tests and monitoring results\u003c\/li\u003e\n\u003cli\u003eSimple, quick report creation using drag and drop tools – faster, more understandable and more accurate reporting for the maintenance manager or a customer contracting the test procedure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral purpose electrical maintenance\u003c\/li\u003e\n\u003cli\u003ePreventive and predictive maintenance\u003c\/li\u003e\n\u003cli\u003eTroubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFluke FLUKE-1555 FC Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cbr\u003e250 kΩ to 5 GΩ\u003cbr\u003e5 GΩ to 50 GΩ\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cbr\u003e500 kΩ to 10 GΩ\u003cbr\u003e10 GΩ to 100 GΩ\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cbr\u003e1 MΩ to 20 GΩ\u003cbr\u003e20 GΩ to 200 GΩ\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cbr\u003e50 GΩ to 500 GΩ\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cbr\u003e5 MΩ to 100 GΩ\u003cbr\u003e100 GΩ to 1 TΩ\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MΩ\u003cbr\u003e10 MΩ to 200 GΩ\u003cbr\u003e10 GΩ to 2 TΩ\u003cbr\u003e\u0026gt; 2 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eResolution Setting: 1 minute Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLive Circuit Warning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWarning Range 30 V to 660 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVoltage Accuracy ± (15 % + 2 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eAdditional\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Graph Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltage Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-0 %, +10 % at 1 mA load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInduced AC Mains Current Rejection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 seconds per °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 s\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eWhat's included with the Fluke FLUKE-1555 FC\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eIR3000FC1550 Connector\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eEnglish Manual\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick Reference Card\u003c\/li\u003e\n\u003cli\u003eSoftware License Agreement\u003c\/li\u003e\n\u003cli\u003eRegistration Card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":31851584651361,"sku":"FLUKE1555FC","price":10130.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/60AC4422-40.jpg?v=1582653982"},{"product_id":"fluke-1555-fc-kit-w-ir3000-10-kv-insulation-tester-kit-with-ir3000-fc-connector","title":"Fluke 1555 FC Kit w\/IR3000 10 kV Insulation Tester Kit with IR3000 FC Connector","description":"\u003cp\u003e\u003cstrong\u003eThe Fluke 1555C Tester together with the IR3000 FC connector and Fluke Connect App allow users to perform advanced insulation testing by wirelessly transfering test results from the tester to Fluke Connect which eliminates error-prone paperwork and saves your technicianÍs time. Kit includes industrial hard case and high voltage test lead.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis insulation resistance tester offers digital insulation testing up to 10 kV, making it ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables. It can conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, it is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen combined with the ir3000FC1550 Connector and Fluke Connect, it provides three unique benefits that increase work efficiency and safety:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time trending – show a graph of current insulation test data on your phone, rather than trying to interpret a hard-to-read set of changing numbers on the tester itself. Makes it easy to see if your test values are shifting in the right direction. You no longer need to import values into a separate spreadsheet\u003c\/li\u003e\n\u003cli\u003eRemote configuration and operation of your tester – take full control of your tester through your smartphone. Remote start and stop allows the user to move out of potentially hazardous zones before engaging tests and monitoring results\u003c\/li\u003e\n\u003cli\u003eSimple, quick report creation using drag and drop tools – faster, more understandable and more accurate reporting for the maintenance manager or a customer contracting the test procedure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral purpose electrical maintenance\u003c\/li\u003e\n\u003cli\u003ePreventive and predictive maintenance\u003c\/li\u003e\n\u003cli\u003eTroubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFluke FLUKE-1555 FC KIT Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cbr\u003e250 kΩ to 5 GΩ\u003cbr\u003e5 GΩ to 50 GΩ\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cbr\u003e500 kΩ to 10 GΩ\u003cbr\u003e10 GΩ to 100 GΩ\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cbr\u003e1 MΩ to 20 GΩ\u003cbr\u003e20 GΩ to 200 GΩ\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cbr\u003e50 GΩ to 500 GΩ\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cbr\u003e5 MΩ to 100 GΩ\u003cbr\u003e100 GΩ to 1 TΩ\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MΩ\u003cbr\u003e10 MΩ to 200 GΩ\u003cbr\u003e10 GΩ to 2 TΩ\u003cbr\u003e\u0026gt; 2 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eResolution Setting: 1 minute Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLive Circuit Warning\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWarning Range 30 V to 660 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVoltage Accuracy ± (15 % + 2 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eAdditional\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Graph Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltage Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-0 %, +10 % at 1 mA load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInduced AC Mains Current Rejection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 seconds per °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Rate for Capacitive Load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 s\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eWhat's included with the Fluke FLUKE-1555 FC KIT\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eIR3000FC1550 Connector\u003c\/li\u003e\n\u003cli\u003eCertificate of Calibration\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eEnglish Manual\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick Reference Card\u003c\/li\u003e\n\u003cli\u003eSoftware License Agreement\u003c\/li\u003e\n\u003cli\u003eRegistration Card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eHeavy Duty Alligator Clip Leads\u003c\/li\u003e\n\u003cli\u003eIP67 Hard Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":31851779981409,"sku":"FLUKE1555FC-KIT","price":11217.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/1555kit.jpg?v=1582655894"},{"product_id":"fluke-1550c-digital-insulation-resistance-tester-with-ir3000-fc-5kv","title":"Fluke 1550C – 5kV Digital Insulation Resistance Tester","description":"\u003cp data-start=\"262\" data-end=\"335\" class=\"\"\u003e\u003cstrong data-start=\"262\" data-end=\"335\"\u003eHigh-Voltage Insulation Testing with 1 TΩ Range and Fluke Reliability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"337\" data-end=\"725\" class=\"\"\u003e\u003cstrong data-start=\"337\" data-end=\"358\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"358\" data-end=\"361\"\u003eThe \u003cstrong data-start=\"365\" data-end=\"380\"\u003eFluke 1550C\u003c\/strong\u003e is a powerful, rugged \u003cstrong data-start=\"403\" data-end=\"443\"\u003edigital insulation resistance tester\u003c\/strong\u003e that provides \u003cstrong data-start=\"458\" data-end=\"489\"\u003etest voltages up to 5,000 V\u003c\/strong\u003e and insulation resistance measurement up to \u003cstrong data-start=\"534\" data-end=\"542\"\u003e1 TΩ\u003c\/strong\u003e. Built for \u003cstrong data-start=\"554\" data-end=\"606\"\u003eindustrial, utility, and commercial applications\u003c\/strong\u003e, this tester is ideal for assessing insulation integrity in motors, transformers, switchgear, and high-voltage cables.\u003c\/p\u003e\n\u003cp data-start=\"727\" data-end=\"1112\" class=\"\"\u003eIt includes \u003cstrong data-start=\"739\" data-end=\"776\"\u003eautomated Polarization Index (PI)\u003c\/strong\u003e and \u003cstrong data-start=\"781\" data-end=\"818\"\u003eDielectric Absorption Ratio (DAR)\u003c\/strong\u003e testing, \u003cstrong data-start=\"828\" data-end=\"854\"\u003ewireless data transfer\u003c\/strong\u003e, and \u003cstrong data-start=\"860\" data-end=\"892\"\u003eFluke Connect® compatibility\u003c\/strong\u003e for real-time mobile logging and reporting. With a large digital display, timer control, and internal memory, the 1550C offers both \u003cstrong data-start=\"1025\" data-end=\"1045\"\u003efield ruggedness\u003c\/strong\u003e and \u003cstrong data-start=\"1050\" data-end=\"1071\"\u003edata traceability\u003c\/strong\u003e for compliance and maintenance programs.\u003c\/p\u003e\n\u003chr data-start=\"1114\" data-end=\"1117\" class=\"\"\u003e\n\u003ch3 data-start=\"1119\" data-end=\"1140\" class=\"\"\u003e\u003cstrong data-start=\"1123\" data-end=\"1140\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1141\" data-end=\"1620\"\u003e\n\u003cli data-start=\"1141\" data-end=\"1209\" class=\"\"\u003e\n\u003cp data-start=\"1143\" data-end=\"1209\" class=\"\"\u003e\u003cstrong data-start=\"1143\" data-end=\"1172\"\u003eSelectable Test Voltages:\u003c\/strong\u003e 250 V to 5000 V in 50 V increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1210\" data-end=\"1268\" class=\"\"\u003e\n\u003cp data-start=\"1212\" data-end=\"1268\" class=\"\"\u003e\u003cstrong data-start=\"1212\" data-end=\"1244\"\u003eInsulation Resistance Range:\u003c\/strong\u003e Up to 1 TΩ (1,000 GΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1269\" data-end=\"1320\" class=\"\"\u003e\n\u003cp data-start=\"1271\" data-end=\"1320\" class=\"\"\u003e\u003cstrong data-start=\"1271\" data-end=\"1291\"\u003ePI \u0026amp; DAR Testing\u003c\/strong\u003e with automatic calculation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1321\" data-end=\"1405\" class=\"\"\u003e\n\u003cp data-start=\"1323\" data-end=\"1405\" class=\"\"\u003e\u003cstrong data-start=\"1323\" data-end=\"1362\"\u003eWireless Fluke Connect® App Support\u003c\/strong\u003e for remote monitoring and saving results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1406\" data-end=\"1455\" class=\"\"\u003e\n\u003cp data-start=\"1408\" data-end=\"1455\" class=\"\"\u003e\u003cstrong data-start=\"1408\" data-end=\"1453\"\u003eInternal Memory for Up to 99 Measurements\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1456\" data-end=\"1509\" class=\"\"\u003e\n\u003cp data-start=\"1458\" data-end=\"1509\" class=\"\"\u003e\u003cstrong data-start=\"1458\" data-end=\"1507\"\u003eLarge Backlit LCD with Analog-Style Bar Graph\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1510\" data-end=\"1571\" class=\"\"\u003e\n\u003cp data-start=\"1512\" data-end=\"1571\" class=\"\"\u003e\u003cstrong data-start=\"1512\" data-end=\"1569\"\u003eGuard Terminal for Eliminating Surface Leakage Errors\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1572\" data-end=\"1620\" class=\"\"\u003e\n\u003cp data-start=\"1574\" data-end=\"1620\" class=\"\"\u003e\u003cstrong data-start=\"1574\" data-end=\"1620\"\u003eCAT III 1000 V \/ CAT IV 600 V Safety Rated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1622\" data-end=\"1625\" class=\"\"\u003e\n\u003ch3 data-start=\"1627\" data-end=\"1644\" class=\"\"\u003e\u003cstrong data-start=\"1631\" data-end=\"1644\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1645\" data-end=\"1850\"\u003e\n\u003cli data-start=\"1645\" data-end=\"1700\" class=\"\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1700\" class=\"\"\u003eHigh-voltage electrical maintenance and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1701\" data-end=\"1746\" class=\"\"\u003e\n\u003cp data-start=\"1703\" data-end=\"1746\" class=\"\"\u003ePower utility substations and switchyards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1747\" data-end=\"1791\" class=\"\"\u003e\n\u003cp data-start=\"1749\" data-end=\"1791\" class=\"\"\u003eIndustrial motor and transformer testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1792\" data-end=\"1850\" class=\"\"\u003e\n\u003cp data-start=\"1794\" data-end=\"1850\" class=\"\"\u003eField service professionals needing wireless data access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1852\" data-end=\"1855\" class=\"\"\u003e\n\u003ch3 data-start=\"1857\" data-end=\"1881\" class=\"\"\u003e\u003cstrong data-start=\"1861\" data-end=\"1881\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1882\" data-end=\"2054\"\u003e\n\u003cli data-start=\"1882\" data-end=\"1915\" class=\"\"\u003e\n\u003cp data-start=\"1884\" data-end=\"1915\" class=\"\"\u003eFluke 1550C Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1916\" data-end=\"1952\" class=\"\"\u003e\n\u003cp data-start=\"1918\" data-end=\"1952\" class=\"\"\u003eTest leads with clips and probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1953\" data-end=\"1975\" class=\"\"\u003e\n\u003cp data-start=\"1955\" data-end=\"1975\" class=\"\"\u003eHard carrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1976\" data-end=\"2014\" class=\"\"\u003e\n\u003cp data-start=\"1978\" data-end=\"2014\" class=\"\"\u003eFluke Connect® software\/app access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2015\" data-end=\"2030\" class=\"\"\u003e\n\u003cp data-start=\"2017\" data-end=\"2030\" class=\"\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2031\" data-end=\"2054\" class=\"\"\u003e\n\u003cp data-start=\"2033\" data-end=\"2054\" class=\"\"\u003eBatteries (installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2056\" data-end=\"2059\" class=\"\"\u003e\n\u003ch3 data-start=\"2061\" data-end=\"2088\" class=\"\"\u003e🔍 \u003cstrong data-start=\"2068\" data-end=\"2088\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2089\" data-end=\"3230\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2089\" data-end=\"2212\"\u003e\n\u003ctr data-start=\"2089\" data-end=\"2212\"\u003e\n\u003cth data-start=\"2089\" data-end=\"2123\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"2123\" data-end=\"2151\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2125\" data-end=\"2140\"\u003eFluke 1550C\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2151\" data-end=\"2180\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2153\" data-end=\"2171\"\u003eMetrel MI 3205\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2180\" data-end=\"2212\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2182\" data-end=\"2195\"\u003eAEMC 5060\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2341\" data-end=\"3230\"\u003e\n\u003ctr data-start=\"2341\" data-end=\"2468\"\u003e\n\u003ctd data-start=\"2341\" data-end=\"2376\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2376\" data-end=\"2405\" data-col-size=\"sm\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2405\" data-end=\"2435\"\u003e5000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2435\" data-end=\"2468\"\u003e5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2469\" data-end=\"2596\"\u003e\n\u003ctd data-start=\"2469\" data-end=\"2504\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-start=\"2504\" data-end=\"2533\" data-col-size=\"sm\"\u003e1 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2533\" data-end=\"2563\"\u003e10 TΩ\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2563\" data-end=\"2596\"\u003e10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2597\" data-end=\"2721\"\u003e\n\u003ctd data-start=\"2597\" data-end=\"2632\" data-col-size=\"sm\"\u003ePI\/DAR Testing\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2632\" data-end=\"2660\"\u003e✅ Auto\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2660\" data-end=\"2689\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2689\" data-end=\"2721\"\u003e✅ Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2722\" data-end=\"2849\"\u003e\n\u003ctd data-start=\"2722\" data-end=\"2757\" data-col-size=\"sm\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd data-start=\"2757\" data-end=\"2786\" data-col-size=\"sm\"\u003eDigital + Bar Graph\u003c\/td\u003e\n\u003ctd data-start=\"2786\" data-end=\"2816\" data-col-size=\"sm\"\u003eGraphical LCD\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2816\" data-end=\"2849\"\u003eDigital + Bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2850\" data-end=\"2974\"\u003e\n\u003ctd data-start=\"2850\" data-end=\"2885\" data-col-size=\"sm\"\u003eWireless Data Transfer\u003c\/td\u003e\n\u003ctd data-start=\"2885\" data-end=\"2913\" data-col-size=\"sm\"\u003e✅ Fluke Connect®\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2913\" data-end=\"2942\"\u003e❌\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2942\" data-end=\"2974\"\u003e❌\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2975\" data-end=\"3102\"\u003e\n\u003ctd data-start=\"2975\" data-end=\"3010\" data-col-size=\"sm\"\u003eInternal Memory\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3010\" data-end=\"3039\"\u003e99 results\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3039\" data-end=\"3069\"\u003eExtensive w\/ USB\/RS232\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3069\" data-end=\"3102\"\u003e1280 results + USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3103\" data-end=\"3230\"\u003e\n\u003ctd data-start=\"3103\" data-end=\"3138\" data-col-size=\"sm\"\u003eBest Use\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3138\" data-end=\"3167\"\u003eField + mobile diagnostics\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3167\" data-end=\"3197\"\u003eLab + field diagnostics\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3197\" data-end=\"3230\"\u003eIndustrial data-heavy testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":31851792859233,"sku":"FLUKE1550C-FC","price":9258.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/60AC4420-40.jpg?v=1582656315"},{"product_id":"ut513a","title":"UT513A 5kV Insulation Resistance Tester","description":"\u003cp data-start=\"294\" data-end=\"614\"\u003e\u003cstrong data-start=\"294\" data-end=\"314\"\u003eWhat does it do?\u003c\/strong\u003e\u003cbr data-start=\"314\" data-end=\"317\"\u003eThe UT513A is a high-voltage insulation resistance tester designed to measure insulation performance in industrial and utility environments. It supports test voltages up to 5,000V and resistance measurements up to 1TΩ, making it ideal for motors, transformers, switchgear, and high-voltage cables.\u003c\/p\u003e\n\u003cp data-start=\"616\" data-end=\"852\"\u003e\u003cstrong data-start=\"616\" data-end=\"634\"\u003eWho is it for?\u003c\/strong\u003e\u003cbr data-start=\"634\" data-end=\"637\"\u003eThis instrument is built for electrical maintenance professionals, service technicians, and engineers who need a reliable tool for preventive maintenance, troubleshooting, or commissioning of high-voltage equipment.\u003c\/p\u003e\n\u003cp data-start=\"854\" data-end=\"877\"\u003e\u003cstrong data-start=\"854\" data-end=\"875\"\u003eWhy is it better?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"878\" data-end=\"1370\"\u003e\n\u003cli data-start=\"878\" data-end=\"966\"\u003e\n\u003cp data-start=\"880\" data-end=\"966\"\u003e\u003cstrong data-start=\"880\" data-end=\"907\"\u003eWide Test Voltage Range\u003c\/strong\u003e: Selectable test voltages of 500V, 1000V, 2500V, and 5000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"967\" data-end=\"1031\"\u003e\n\u003cp data-start=\"969\" data-end=\"1031\"\u003e\u003cstrong data-start=\"969\" data-end=\"999\"\u003eHigh Resistance Capability\u003c\/strong\u003e: Measures up to 1 teraohm (1TΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1032\" data-end=\"1124\"\u003e\n\u003cp data-start=\"1034\" data-end=\"1124\"\u003e\u003cstrong data-start=\"1034\" data-end=\"1060\"\u003eLive Circuit Detection\u003c\/strong\u003e: Automatically warns of voltage presence to enhance user safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1125\" data-end=\"1188\"\u003e\n\u003cp data-start=\"1127\" data-end=\"1188\"\u003e\u003cstrong data-start=\"1127\" data-end=\"1143\"\u003eData Storage\u003c\/strong\u003e: Save and recall up to 18 groups of readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1189\" data-end=\"1279\"\u003e\n\u003cp data-start=\"1191\" data-end=\"1279\"\u003e\u003cstrong data-start=\"1191\" data-end=\"1210\"\u003ePC Connectivity\u003c\/strong\u003e: Includes USB interface and software for data analysis and reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1280\" data-end=\"1370\"\u003e\n\u003cp data-start=\"1282\" data-end=\"1370\"\u003e\u003cstrong data-start=\"1282\" data-end=\"1304\"\u003eCAT III 600V Rated\u003c\/strong\u003e: Meets international safety standards for industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1372\" data-end=\"1421\"\u003e\u003cstrong data-start=\"1372\" data-end=\"1394\"\u003eWhat happens next?\u003c\/strong\u003e\u003cbr data-start=\"1394\" data-end=\"1397\"\u003eOrder today and receive:\u003c\/p\u003e\n\u003cul data-start=\"1422\" data-end=\"1535\"\u003e\n\u003cli data-start=\"1422\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1424\" data-end=\"1448\"\u003eUT513A insulation tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1477\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1477\"\u003eTest leads and accessories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1478\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1493\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1494\" data-end=\"1507\"\u003e\n\u003cp data-start=\"1496\" data-end=\"1507\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1508\" data-end=\"1535\"\u003e\n\u003cp data-start=\"1510\" data-end=\"1535\"\u003eUSB cable and PC software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eSPECIAL FUNCTIONS:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAuto Ranging\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShort Circuit Current: \u0026lt; 1.8mA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData Logging : 18\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSleep Mode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePolarization index (PI)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDielectric Absorption (DAR)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTimer Around: 15 minutes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompare\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery Display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWhite Display Backlight\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOver Range and High\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoltage Warning\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUSB\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMax. Display: 9999 \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eSPECIFICATION:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eInsulation Resistance: 0.5MOhm ~1000GOhm \u003c\/span\u003e\u003cspan\u003e- accuracy: +\/- (3%+5)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eTesting Voltage: 500V \/ 1000V\/ 2500V\/5000V \u003c\/span\u003e\u003cspan\u003e- accuracy: 0 ~ 20%\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDC Voltage: 600V \u003c\/span\u003e\u003cspan\u003e- best accuracy: +\/- (2%+5) \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eAC Voltage: 600V \u003c\/span\u003e\u003cspan\u003e- best accuracy: +\/- (2%+5)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower: 1.5V Alkaline Battery(LR14)×8\u003c\/li\u003e\n\u003cli\u003eSize: 202×155×94 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 2 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":31858745049185,"sku":"UT513A","price":885.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/28a75067dce172cfb4a55e97d2bc5dd6.jpg?v=1582829874"},{"product_id":"ut502a-2-5-kv-insulation-resistance-tester","title":"UT502A 2.5 kV Insulation Resistance Tester","description":"\u003cdiv class=\"product-description\"\u003eUT500 series insulation testers are used to measure the insulation resistance of electrical  equipment and household appliances. This is done by measuring the insulation resistance between electrical circuits or between circuits and ground. UT500 series can measure insulation resistance, AC Voltage, low resistance, PI (Polarization Index) and DAR (Dielectric Absorption). These are ideal  tools for ensuring transformers, genera-tors, high voltage motors, power capacitors, power cables, arresters and other electrical equipment that can operate in a safe and accurate manner.\u003c\/div\u003e\n\u003cdiv class=\"product-description\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"product-description\"\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e2000 count LCD display, overload indication, backlight\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eAC voltage measurement, auto power oﬀ\u003c\/li\u003e\n\u003cli\u003eAuto discharge\u003c\/li\u003e\n\u003cli\u003eContinuous measurements mode, red warning light and buzzer function\u003c\/li\u003e\n\u003cli\u003eContinuous low resistance measurement \u003c\/li\u003e\n\u003cli\u003ePI and DAR measurement, auto resistivity calculation \u003c\/li\u003e\n\u003cli\u003eLow resistance returning to zero function to improve accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"product-description\"\u003e\u003c\/div\u003e\n\u003ch3 class=\"product-description\"\u003eApplications:\u003c\/h3\u003e\n\u003cdiv class=\"product-description\"\u003eIt is used for insulation resistance measurement for insulation materials and various kinds of electric equipment such as transformer, electric machines, cables, switches, electrical appliance, a ideal tool for electric maintenance, testing and inspection.\u003c\/div\u003e\n\u003cdiv class=\"product-description\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"585\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd\u003e　\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eUT502A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"224\" rowspan=\"14\"\u003eInsulation resistance (Ω)\u003c\/td\u003e\n\u003ctd\u003eTest voltages\u003c\/td\u003e\n\u003ctd\u003e500V\/1000V\/2500V\u003c\/td\u003e\n\u003ctd\u003e0%~10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"32\" rowspan=\"2\"\u003e500V\u003c\/td\u003e\n\u003ctd\u003e0MΩ~99.9MΩ\u003c\/td\u003e\n\u003ctd\u003e±(3%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e100MΩ~5GΩ\u003c\/td\u003e\n\u003ctd\u003e±(5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"32\" rowspan=\"2\"\u003e1000V\u003c\/td\u003e\n\u003ctd\u003e0MΩ~99.9MΩ\u003c\/td\u003e\n\u003ctd\u003e±(3%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e100MΩ~5GΩ\u003c\/td\u003e\n\u003ctd\u003e±(5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"48\" rowspan=\"3\"\u003e2500V\u003c\/td\u003e\n\u003ctd\u003e0MΩ~99.9MΩ\u003c\/td\u003e\n\u003ctd\u003e±(3%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e100MΩ~9.9GΩ\u003c\/td\u003e\n\u003ctd\u003e±(5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e10GΩ~20GΩ\u003c\/td\u003e\n\u003ctd\u003e±(10%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"96\" rowspan=\"6\"\u003eLoad current\u003c\/td\u003e\n\u003ctd\u003e50V (R=50kΩ) 1mA\u003c\/td\u003e\n\u003ctd\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e100V (R=100kΩ) 1mA\u003c\/td\u003e\n\u003ctd\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e250V (R=250kΩ) 1mA\u003c\/td\u003e\n\u003ctd\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e500V (R=500kΩ) 1mA\u003c\/td\u003e\n\u003ctd\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e1000V (R=1MΩ) 1mA\u003c\/td\u003e\n\u003ctd\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e2500V (R=1MΩ) 1mA\u003c\/td\u003e\n\u003ctd\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e　\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eLow resistance (Ω)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01Ω~200Ω (about 5.0V\/\u0026gt;200mA）\u003c\/td\u003e\n\u003ctd\u003e±(2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eAC voltage (V)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30V~600V\u003c\/td\u003e\n\u003ctd\u003e±(2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd colspan=\"4\" height=\"16\"\u003eFeatures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eDisplay count\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e　\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eDAR\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60s\/15s and 60s\/30s\u003c\/td\u003e\n\u003ctd\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003ePI\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e　\u003c\/td\u003e\n\u003ctd\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eAuto range\/Low battery indication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e　\u003c\/td\u003e\n\u003ctd\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eLCD backlight\/Light alarm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e　\u003c\/td\u003e\n\u003ctd\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eBuzzer alarm\/High voltage indication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e　\u003c\/td\u003e\n\u003ctd\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eOver load indication\/Auto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e　\u003c\/td\u003e\n\u003ctd\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eTest voltage secondary display\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e　\u003c\/td\u003e\n\u003ctd\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003e10MΩ internal resistance test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e　\u003c\/td\u003e\n\u003ctd\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eMeets IEC 61557\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e61557-1:2007; 61557-2:2007; 61557-4:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd colspan=\"4\" height=\"16\"\u003e\u003cstrong\u003eGeneral Characterisitics\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1.5V battery (LR6) x 6  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e70.6mm x 34mm     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eProduct color\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eRed and grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eProduct net weight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e500g  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\"\u003eProduct size\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e150mm x 100mm x 71mm  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eStandard accessories\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eBatteries, test leads, alligator clips, gallus, test probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-description\"\u003e\u003c\/div\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":31858789908577,"sku":"UT502A","price":278.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/insulation-resistance-tester-uni-t-ut502a.jpg?v=1582831548"},{"product_id":"ut501a-1-kv-insulation-resistance-tester","title":"UT501A – 1kV Digital Insulation Resistance Tester","description":"\u003cp data-start=\"257\" data-end=\"350\" class=\"\"\u003e\u003cstrong data-start=\"257\" data-end=\"350\"\u003eAffordable and Reliable Insulation Testing for Electricians and Maintenance Professionals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"276\" data-end=\"563\"\u003e\u003cstrong data-start=\"276\" data-end=\"296\"\u003eWhat does it do?\u003c\/strong\u003e\u003cbr data-start=\"296\" data-end=\"299\"\u003eThe UT501A is a compact digital insulation resistance tester capable of applying test voltages up to 1000V and measuring insulation resistance up to 5GΩ. It’s ideal for quick and reliable insulation checks on cables, motors, electrical panels, and small machinery.\u003c\/p\u003e\n\u003cp data-start=\"565\" data-end=\"754\"\u003e\u003cstrong data-start=\"565\" data-end=\"583\"\u003eWho is it for?\u003c\/strong\u003e\u003cbr data-start=\"583\" data-end=\"586\"\u003eDesigned for electricians, HVAC technicians, and general maintenance personnel who need a simple, portable, and affordable solution for insulation testing in the field.\u003c\/p\u003e\n\u003cp data-start=\"756\" data-end=\"779\"\u003e\u003cstrong data-start=\"756\" data-end=\"777\"\u003eWhy is it better?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"780\" data-end=\"1218\"\u003e\n\u003cli data-start=\"780\" data-end=\"846\"\u003e\n\u003cp data-start=\"782\" data-end=\"846\"\u003e\u003cstrong data-start=\"782\" data-end=\"799\"\u003eTest Voltages\u003c\/strong\u003e: Selectable 100V, 250V, 500V, and 1000V ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"847\" data-end=\"918\"\u003e\n\u003cp data-start=\"849\" data-end=\"918\"\u003e\u003cstrong data-start=\"849\" data-end=\"869\"\u003eResistance Range\u003c\/strong\u003e: Measures insulation resistance up to 5 gigaohms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"919\" data-end=\"1001\"\u003e\n\u003cp data-start=\"921\" data-end=\"1001\"\u003e\u003cstrong data-start=\"921\" data-end=\"945\"\u003eLive Voltage Warning\u003c\/strong\u003e: Alerts the user when voltage is present on the circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1002\" data-end=\"1064\"\u003e\n\u003cp data-start=\"1004\" data-end=\"1064\"\u003e\u003cstrong data-start=\"1004\" data-end=\"1026\"\u003eData Hold Function\u003c\/strong\u003e: Easily capture and read measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1065\" data-end=\"1126\"\u003e\n\u003cp data-start=\"1067\" data-end=\"1126\"\u003e\u003cstrong data-start=\"1067\" data-end=\"1086\"\u003eBacklit Display\u003c\/strong\u003e: Clear readings even in dimly lit areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1127\" data-end=\"1218\"\u003e\n\u003cp data-start=\"1129\" data-end=\"1218\"\u003e\u003cstrong data-start=\"1129\" data-end=\"1159\"\u003eBattery and Auto Power Off\u003c\/strong\u003e: Long battery life with intelligent shutdown to save power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"893\" data-end=\"896\" class=\"\"\u003e\n\u003ch3 data-start=\"898\" data-end=\"919\" class=\"\"\u003e\u003cstrong data-start=\"902\" data-end=\"919\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"920\" data-end=\"1383\"\u003e\n\u003cli data-start=\"920\" data-end=\"970\" class=\"\"\u003e\n\u003cp data-start=\"922\" data-end=\"970\" class=\"\"\u003e\u003cstrong data-start=\"922\" data-end=\"940\"\u003eTest Voltages:\u003c\/strong\u003e 100 V, 250 V, 500 V, 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"971\" data-end=\"1024\" class=\"\"\u003e\n\u003cp data-start=\"973\" data-end=\"1024\" class=\"\"\u003e\u003cstrong data-start=\"973\" data-end=\"1011\"\u003eInsulation Resistance Measurement:\u003c\/strong\u003e Up to 5 GΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1025\" data-end=\"1066\" class=\"\"\u003e\n\u003cp data-start=\"1027\" data-end=\"1066\" class=\"\"\u003e\u003cstrong data-start=\"1027\" data-end=\"1052\"\u003eAC Voltage Detection:\u003c\/strong\u003e Up to 750 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1067\" data-end=\"1116\" class=\"\"\u003e\n\u003cp data-start=\"1069\" data-end=\"1116\" class=\"\"\u003e\u003cstrong data-start=\"1069\" data-end=\"1114\"\u003eAutomatic Discharge of Capacitive Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1117\" data-end=\"1161\" class=\"\"\u003e\n\u003cp data-start=\"1119\" data-end=\"1161\" class=\"\"\u003e\u003cstrong data-start=\"1119\" data-end=\"1142\"\u003eLive Wire Detection\u003c\/strong\u003e for added safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1162\" data-end=\"1224\" class=\"\"\u003e\n\u003cp data-start=\"1164\" data-end=\"1224\" class=\"\"\u003e\u003cstrong data-start=\"1164\" data-end=\"1187\"\u003eBacklit LCD Display\u003c\/strong\u003e for visibility in dim environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1225\" data-end=\"1274\" class=\"\"\u003e\n\u003cp data-start=\"1227\" data-end=\"1274\" class=\"\"\u003e\u003cstrong data-start=\"1227\" data-end=\"1272\"\u003eContinuity Buzzer and Overload Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1275\" data-end=\"1344\" class=\"\"\u003e\n\u003cp data-start=\"1277\" data-end=\"1344\" class=\"\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1307\"\u003ePortable and Rugged Design\u003c\/strong\u003e with shoulder strap and carry case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1345\" data-end=\"1383\" class=\"\"\u003e\n\u003cp data-start=\"1347\" data-end=\"1383\" class=\"\"\u003e\u003cstrong data-start=\"1347\" data-end=\"1383\"\u003eIEC 61010-1, CAT III 600 V Rated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1385\" data-end=\"1388\" class=\"\"\u003e\n\u003ch3 data-start=\"1390\" data-end=\"1407\" class=\"\"\u003e\u003cstrong data-start=\"1394\" data-end=\"1407\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1408\" data-end=\"1538\"\u003e\n\u003cli data-start=\"1408\" data-end=\"1450\" class=\"\"\u003e\n\u003cp data-start=\"1410\" data-end=\"1450\" class=\"\"\u003eElectrical maintenance and inspections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1451\" data-end=\"1480\" class=\"\"\u003e\n\u003cp data-start=\"1453\" data-end=\"1480\" class=\"\"\u003eHVAC and appliance repair\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1481\" data-end=\"1508\" class=\"\"\u003e\n\u003cp data-start=\"1483\" data-end=\"1508\" class=\"\"\u003eMotor and cable testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1509\" data-end=\"1538\" class=\"\"\u003e\n\u003cp data-start=\"1511\" data-end=\"1538\" class=\"\"\u003eField service technicians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1540\" data-end=\"1543\" class=\"\"\u003e\n\u003ch3 data-start=\"1545\" data-end=\"1569\" class=\"\"\u003e\u003cstrong data-start=\"1549\" data-end=\"1569\"\u003eWhat's Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1570\" data-end=\"1695\"\u003e\n\u003cli data-start=\"1570\" data-end=\"1604\" class=\"\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1604\" class=\"\"\u003eUNI-T UT501A Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1605\" data-end=\"1639\" class=\"\"\u003e\n\u003cp data-start=\"1607\" data-end=\"1639\" class=\"\"\u003eTest leads and alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1640\" data-end=\"1653\" class=\"\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1653\" class=\"\"\u003eBatteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1669\" class=\"\"\u003e\n\u003cp data-start=\"1656\" data-end=\"1669\" class=\"\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1670\" data-end=\"1695\" class=\"\"\u003e\n\u003cp data-start=\"1672\" data-end=\"1695\" class=\"\"\u003eProtective carry case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1697\" data-end=\"1700\" class=\"\"\u003e\n\u003ch3 data-start=\"1702\" data-end=\"1729\" class=\"\"\u003e🔍 \u003cstrong data-start=\"1709\" data-end=\"1729\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1730\" data-end=\"2403\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1730\" data-end=\"1826\"\u003e\n\u003ctr data-start=\"1730\" data-end=\"1826\"\u003e\n\u003cth data-start=\"1730\" data-end=\"1755\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1755\" data-end=\"1775\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1757\" data-end=\"1767\"\u003eUT501A\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1775\" data-end=\"1800\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1777\" data-end=\"1795\"\u003eKyoritsu 3132A\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1800\" data-end=\"1826\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1802\" data-end=\"1816\"\u003eFluke 1503\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1923\" data-end=\"2403\"\u003e\n\u003ctr data-start=\"1923\" data-end=\"2018\"\u003e\n\u003ctd data-start=\"1923\" data-end=\"1948\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1948\" data-end=\"1967\"\u003e1000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1967\" data-end=\"1992\"\u003e1000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1992\" data-end=\"2018\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2019\" data-end=\"2114\"\u003e\n\u003ctd data-start=\"2019\" data-end=\"2044\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-start=\"2044\" data-end=\"2063\" data-col-size=\"sm\"\u003e5 GΩ\u003c\/td\u003e\n\u003ctd data-start=\"2063\" data-end=\"2088\" data-col-size=\"sm\"\u003e2000 MΩ (2 GΩ)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2088\" data-end=\"2114\"\u003e2 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2115\" data-end=\"2211\"\u003e\n\u003ctd data-start=\"2115\" data-end=\"2140\" data-col-size=\"sm\"\u003eMultimeter Functions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2140\" data-end=\"2160\"\u003eBasic voltage only\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2160\" data-end=\"2185\"\u003eNo multimeter\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2185\" data-end=\"2211\"\u003eNo multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2212\" data-end=\"2307\"\u003e\n\u003ctd data-start=\"2212\" data-end=\"2237\" data-col-size=\"sm\"\u003ePortability\u003c\/td\u003e\n\u003ctd data-start=\"2237\" data-end=\"2256\" data-col-size=\"sm\"\u003eLightweight case\u003c\/td\u003e\n\u003ctd data-start=\"2256\" data-end=\"2281\" data-col-size=\"sm\"\u003eAnalog dial, compact\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2281\" data-end=\"2307\"\u003eRugged, Fluke build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2308\" data-end=\"2403\"\u003e\n\u003ctd data-start=\"2308\" data-end=\"2333\" data-col-size=\"sm\"\u003ePrice Point\u003c\/td\u003e\n\u003ctd data-start=\"2333\" data-end=\"2352\" data-col-size=\"sm\"\u003e✅ Budget-friendly\u003c\/td\u003e\n\u003ctd data-start=\"2352\" data-end=\"2377\" data-col-size=\"sm\"\u003eMid-range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2377\" data-end=\"2403\"\u003eHigher-end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":31858800459873,"sku":"UT501A","price":179.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/71e1tpZ6oCL._AC_SL1200.jpg?v=1582832016"},{"product_id":"ut502a-1-kv-insulation-resistance-tester","title":"UT502A 2.5 kV Insulation Resistance Tester","description":"\u003cp\u003eUT502A 2.5KV insulation testers are used to measure the insulation resistance of electrical equipment and household appliances. This is done by measuring the insulation resistance between electrical circuits or between circuits and ground. UT502A can measure insulation resistance, AC Voltage, low resistance, PI (Polarization Index) and DAR (Dielectric Absorption). These are dieal tools for ensuring transformers, genera-tors, high voltage motors, power capacitors, power cables, arresters and other electrical equipment that can operate in a safe and accurate manner.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e3 test voltages: 500V, 1000V, 2500V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuity test : 200mA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e2000 count LCD display, overload indication, backlight\u003c\/span\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eAC voltage measurement, auto power oﬀ\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eAuto discharge\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eContinuous measurements mode, red warning light and buzzer function\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eContinuous low resistance measurement \u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003ePI and DAR measurement, auto resistivity calculation \u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eLow resistance returning to zero function to improve accuracy\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUT501A Technical Specifications\u003c\/h2\u003e\n \n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 538px;\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd style=\"width: 93px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 159px;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003eUT502A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"224\" rowspan=\"14\" style=\"width: 200px;\"\u003eInsulation resistance (Ω)\u003c\/td\u003e\n\u003ctd style=\"width: 93px;\"\u003eTest voltages\u003c\/td\u003e\n\u003ctd style=\"width: 159px;\"\u003e500V\/1000V\/2500V\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e0%~10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"32\" rowspan=\"2\" style=\"width: 93px;\"\u003e500V\u003c\/td\u003e\n\u003ctd style=\"width: 159px;\"\u003e0MΩ~99.9MΩ\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e±(3%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 159px;\"\u003e100MΩ~5GΩ\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e±(5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"32\" rowspan=\"2\" style=\"width: 93px;\"\u003e1000V\u003c\/td\u003e\n\u003ctd style=\"width: 159px;\"\u003e0MΩ~99.9MΩ\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e±(3%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 159px;\"\u003e100MΩ~5GΩ\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e±(5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"48\" rowspan=\"3\" style=\"width: 93px;\"\u003e2500V\u003c\/td\u003e\n\u003ctd style=\"width: 159px;\"\u003e0MΩ~99.9MΩ\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e±(3%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 159px;\"\u003e100MΩ~9.9GΩ\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e±(5%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 159px;\"\u003e10GΩ~20GΩ\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e±(10%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"96\" rowspan=\"6\" style=\"width: 93px;\"\u003eLoad current\u003c\/td\u003e\n\u003ctd style=\"width: 159px;\"\u003e50V (R=50kΩ) 1mA\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 159px;\"\u003e100V (R=100kΩ) 1mA\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 159px;\"\u003e250V (R=250kΩ) 1mA\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 159px;\"\u003e500V (R=500kΩ) 1mA\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 159px;\"\u003e1000V (R=1MΩ) 1mA\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 159px;\"\u003e2500V (R=1MΩ) 1mA\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e0%~10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e\u0026lt;2mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eLow resistance (Ω)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e0.01Ω~200Ω (about 5.0V\/\u0026gt;200mA）\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e±(2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eAC voltage (V)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e30V~600V\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e±(2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd colspan=\"4\" height=\"16\" style=\"width: 530px;\"\u003eFeatures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eDisplay count\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eDAR\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e60s\/15s and 60s\/30s\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003ePI\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eAuto range\/Low battery indication\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eLCD backlight\/Light alarm\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eBuzzer alarm\/High voltage indication\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eOver load indication\/Auto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eTest voltage secondary display\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003e10MΩ internal resistance test\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 252px;\"\u003e　\u003c\/td\u003e\n\u003ctd style=\"width: 78px;\"\u003e√\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eMeets IEC 61557\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003e61557-1:2007; 61557-2:2007; 61557-4:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd colspan=\"4\" height=\"16\" style=\"width: 530px;\"\u003eGeneral Characterisitics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003e1.5V battery (LR6) x 6  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003e70.6mm x 34mm     \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eProduct color\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003eRed and grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eProduct net weight\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003e500g  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eProduct size\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003e150mm x 100mm x 71mm  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\" style=\"width: 200px;\"\u003eStandard accessories\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003eBatteries, test leads, alligator clips, gallus, test probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eStandard individual packing\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003eGift box, carrying bag, English manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eStandard quantity per carton\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003e20pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" style=\"width: 200px;\"\u003eStandard carton measurement\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003e500mm x 380mm x 330mm (0.063 CBM per standard carton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"16\"\u003e\n\u003ctd height=\"16\" style=\"width: 200px;\"\u003eStandard carton gross weight\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 330px;\"\u003e2 lbs\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/UT501A-datasheet.pdf?v=1584106892\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":31926486466657,"sku":"UT502A","price":278.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/71xdxItSvVL._AC_SL1200_dd9401d7-e5b3-4dcc-bd87-6e91aa30b0ea.jpg?v=1584386255"},{"product_id":"sew-2132in-1000v-analogue-insulation-resistance-tester","title":"2132IN – 1000V Analog Insulation Resistance Tester","description":"\u003cp data-start=\"278\" data-end=\"331\" class=\"\"\u003e\u003cstrong data-start=\"278\" data-end=\"331\"\u003eRugged, Analog Megohmmeter for Reliable Field Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"333\" data-end=\"708\" class=\"\"\u003e\u003cstrong data-start=\"333\" data-end=\"354\"\u003eProduct Overview:\u003c\/strong\u003e\u003cbr data-start=\"354\" data-end=\"357\"\u003eThe \u003cstrong data-start=\"361\" data-end=\"375\"\u003eSEW 2132IN\u003c\/strong\u003e is a robust, analog \u003cstrong data-start=\"396\" data-end=\"429\"\u003emegohmmeter insulation tester\u003c\/strong\u003e designed for electricians and field technicians who prefer analog displays for their fast response and clarity. With insulation resistance testing up to \u003cstrong data-start=\"583\" data-end=\"604\"\u003e1000 V and 200 MΩ\u003c\/strong\u003e, this tester is ideal for basic insulation diagnostics in motors, panels, and electrical installations.\u003c\/p\u003e\n\u003cp data-start=\"710\" data-end=\"880\" class=\"\"\u003eIts analog dial and mirror scale reduce parallax errors and provide fast, intuitive readings—even in bright sunlight or harsh environments where digital screens may fail.\u003c\/p\u003e\n\u003chr data-start=\"882\" data-end=\"885\" class=\"\"\u003e\n\u003ch3 data-start=\"887\" data-end=\"908\" class=\"\"\u003e\u003cstrong data-start=\"891\" data-end=\"908\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"909\" data-end=\"1306\"\u003e\n\u003cli data-start=\"909\" data-end=\"952\" class=\"\"\u003e\n\u003cp data-start=\"911\" data-end=\"952\" class=\"\"\u003e\u003cstrong data-start=\"911\" data-end=\"929\"\u003eTest Voltages:\u003c\/strong\u003e 250 V, 500 V, 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"953\" data-end=\"1002\" class=\"\"\u003e\n\u003cp data-start=\"955\" data-end=\"1002\" class=\"\"\u003e\u003cstrong data-start=\"955\" data-end=\"987\"\u003eInsulation Resistance Range:\u003c\/strong\u003e Up to 200 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1003\" data-end=\"1090\" class=\"\"\u003e\n\u003cp data-start=\"1005\" data-end=\"1090\" class=\"\"\u003e\u003cstrong data-start=\"1005\" data-end=\"1042\"\u003eAnalog Display with Mirror Scale:\u003c\/strong\u003e Fast and clear readings with minimal parallax\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1091\" data-end=\"1127\" class=\"\"\u003e\n\u003cp data-start=\"1093\" data-end=\"1127\" class=\"\"\u003e\u003cstrong data-start=\"1093\" data-end=\"1125\"\u003eContinuity Check with Buzzer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1128\" data-end=\"1163\" class=\"\"\u003e\n\u003cp data-start=\"1130\" data-end=\"1163\" class=\"\"\u003e\u003cstrong data-start=\"1130\" data-end=\"1161\"\u003eBattery-Powered Portability\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1164\" data-end=\"1196\" class=\"\"\u003e\n\u003cp data-start=\"1166\" data-end=\"1196\" class=\"\"\u003e\u003cstrong data-start=\"1166\" data-end=\"1194\"\u003eLive Circuit Warning LED\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1197\" data-end=\"1257\" class=\"\"\u003e\n\u003cp data-start=\"1199\" data-end=\"1257\" class=\"\"\u003e\u003cstrong data-start=\"1199\" data-end=\"1227\"\u003eTest Button Lock Feature\u003c\/strong\u003e for continuous measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1258\" data-end=\"1306\" class=\"\"\u003e\n\u003cp data-start=\"1260\" data-end=\"1306\" class=\"\"\u003e\u003cstrong data-start=\"1260\" data-end=\"1278\"\u003eSafety Rating:\u003c\/strong\u003e IEC 61010-1 CAT III 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1308\" data-end=\"1311\" class=\"\"\u003e\n\u003ch3 data-start=\"1313\" data-end=\"1330\" class=\"\"\u003e\u003cstrong data-start=\"1317\" data-end=\"1330\"\u003eBest For:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1331\" data-end=\"1519\"\u003e\n\u003cli data-start=\"1331\" data-end=\"1396\" class=\"\"\u003e\n\u003cp data-start=\"1333\" data-end=\"1396\" class=\"\"\u003eElectricians working in industrial or commercial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1397\" data-end=\"1466\" class=\"\"\u003e\n\u003cp data-start=\"1399\" data-end=\"1466\" class=\"\"\u003eProfessionals who prefer analog meters for insulation diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1467\" data-end=\"1519\" class=\"\"\u003e\n\u003cp data-start=\"1469\" data-end=\"1519\" class=\"\"\u003eLow-cost, reliable insulation testing in the field\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1521\" data-end=\"1524\" class=\"\"\u003e\n\u003ch3 data-start=\"1526\" data-end=\"1550\" class=\"\"\u003e\u003cstrong data-start=\"1530\" data-end=\"1550\"\u003eWhat's Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1551\" data-end=\"1668\"\u003e\n\u003cli data-start=\"1551\" data-end=\"1583\" class=\"\"\u003e\n\u003cp data-start=\"1553\" data-end=\"1583\" class=\"\"\u003eSEW 2132IN Insulation Tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1584\" data-end=\"1609\" class=\"\"\u003e\n\u003cp data-start=\"1586\" data-end=\"1609\" class=\"\"\u003eTest leads and probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1610\" data-end=\"1623\" class=\"\"\u003e\n\u003cp data-start=\"1612\" data-end=\"1623\" class=\"\"\u003eBatteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1624\" data-end=\"1646\" class=\"\"\u003e\n\u003cp data-start=\"1626\" data-end=\"1646\" class=\"\"\u003eInstruction manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1647\" data-end=\"1668\" class=\"\"\u003e\n\u003cp data-start=\"1649\" data-end=\"1668\" class=\"\"\u003eSturdy carry case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1670\" data-end=\"1673\" class=\"\"\u003e\n\u003ch3 data-start=\"1675\" data-end=\"1702\" class=\"\"\u003e🔍 \u003cstrong data-start=\"1682\" data-end=\"1702\"\u003eHow It Compares:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1703\" data-end=\"2547\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1703\" data-end=\"1807\"\u003e\n\u003ctr data-start=\"1703\" data-end=\"1807\"\u003e\n\u003cth data-start=\"1703\" data-end=\"1728\" data-col-size=\"sm\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1728\" data-end=\"1751\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1730\" data-end=\"1744\"\u003eSEW 2132IN\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1751\" data-end=\"1779\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1753\" data-end=\"1771\"\u003eKyoritsu 3132A\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1779\" data-end=\"1807\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1781\" data-end=\"1795\"\u003eFluke 1503\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1914\" data-end=\"2547\"\u003e\n\u003ctr data-start=\"1914\" data-end=\"2019\"\u003e\n\u003ctd data-start=\"1914\" data-end=\"1939\" data-col-size=\"sm\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1939\" data-end=\"1962\"\u003eAnalog (mirror scale)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1962\" data-end=\"1991\"\u003eAnalog\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1991\" data-end=\"2019\"\u003eDigital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2020\" data-end=\"2125\"\u003e\n\u003ctd data-start=\"2020\" data-end=\"2045\" data-col-size=\"sm\"\u003eMax Test Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2045\" data-end=\"2068\"\u003e1000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2068\" data-end=\"2097\"\u003e1000 V\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2097\" data-end=\"2125\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2126\" data-end=\"2231\"\u003e\n\u003ctd data-start=\"2126\" data-end=\"2151\" data-col-size=\"sm\"\u003eMax Resistance Range\u003c\/td\u003e\n\u003ctd data-start=\"2151\" data-end=\"2174\" data-col-size=\"sm\"\u003e200 MΩ\u003c\/td\u003e\n\u003ctd data-start=\"2174\" data-end=\"2203\" data-col-size=\"sm\"\u003e2000 MΩ (2 GΩ)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2203\" data-end=\"2231\"\u003e2 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2232\" data-end=\"2334\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2257\" data-col-size=\"sm\"\u003eContinuity Check\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2257\" data-end=\"2279\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2279\" data-end=\"2307\"\u003e✅ Yes\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2307\" data-end=\"2334\"\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2335\" data-end=\"2440\"\u003e\n\u003ctd data-start=\"2335\" data-end=\"2360\" data-col-size=\"sm\"\u003ePortability\u003c\/td\u003e\n\u003ctd data-start=\"2360\" data-end=\"2383\" data-col-size=\"sm\"\u003eCompact and rugged\u003c\/td\u003e\n\u003ctd data-start=\"2383\" data-end=\"2412\" data-col-size=\"sm\"\u003eLightweight, simple\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2412\" data-end=\"2440\"\u003eHeavier, rugged build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2441\" data-end=\"2547\"\u003e\n\u003ctd data-start=\"2441\" data-end=\"2466\" data-col-size=\"sm\"\u003eIdeal Use\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2466\" data-end=\"2489\"\u003eOn-site inspections\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2489\" data-end=\"2518\"\u003eGeneral-purpose testing\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2518\" data-end=\"2547\"\u003eHigher-end insulation work\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sperry","offers":[{"title":"Default Title","offer_id":32310226190433,"sku":"SW2132IN","price":189.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/2132IN.jpg?v=1590081261"},{"product_id":"8052-in-analog-insulation-tester","title":"8052-IN 1000V Analog Insulation Tester","description":"\u003cp\u003e\u003cspan\u003eAnalog Insulation Tester with high quality Taut Band movement.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThree insulation test voltages(DC): 250V, 500V, 1000V.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eTwo continuity test on “low ohms”: 3Ω \u0026amp; 500Ω.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHigh quality Taut Band movement.\u003cbr\u003eThree insulation test voltages(DC): 250V, 500V, 1000V.\u003cbr\u003eTwo continuity test on “low ohms”:3Ω \u0026amp; 500Ω.\u003cbr\u003eAC voltmeter with linear scale up to 600 Vac.\u003cbr\u003e200mA short circuit current for continuity.\u003cbr\u003e1mA test current on insulation test at nominal voltage.\u003cbr\u003eAutomatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.\u003cbr\u003eLive warning and display of external voltage presence.\u003cbr\u003eFuse, air gap, crowbar and overload protected.\u003cbr\u003eOn line battery monitoring shows if battery is ok.\u003cbr\u003eManual zero ohm adjustment.\u003cbr\u003eLow battery consumption.\u003cbr\u003eMirror scale.\u003cbr\u003ePush and turn locking switch for continuous and hand free testing.\u003cbr\u003eSupplied with high quality test leads.\u003cbr\u003eBS 16 edition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003cbr\u003eTest voltage (DC V): 250V \/ 500V \/ 1000V\u003cbr\u003eMeasuring ranges: 0-100MΩ \/ 0-200MΩ \/ 0-400MΩ\u003cbr\u003eMid-scale value: 1MO \/ 2MO \/ 4MO\u003cbr\u003eScale multiplier: ×1\/2 \/ ×1 \/ ×2\u003cbr\u003eAccuracy: ± 5% of full scale\u003cbr\u003eOutput voltage open circuit: Rated test voltage +10%\u003cbr\u003eOutput short-circuit current: ≥ 1.0mA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContinuity\u003c\/strong\u003e\u003cbr\u003eMeasuring ranges: 3Ω \/ 50Ω\u003cbr\u003ezero Ω adjustment by knob\u003cbr\u003eOutput short-circuit current: ≥ 200 mA\u003cbr\u003eAccuracy: ± 1.5% of scale length\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAC\/DC Voltage\u003c\/strong\u003e\u003cbr\u003eMeasuring ranges: 0-600V AC\u003cbr\u003eAccuracy: ± 3% of scale length\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003cbr\u003eWarning light circuit live lit From 90Vdc \/ 70Vac, Buzzer beep from 24V ac\/dc\u003cbr\u003eDimensions: 221(L) × 110(W) × 56.8(D)mm\u003cbr\u003eWeight (battery included): Approx. 600g\u003cbr\u003ePower source: 1.5V (AA) × 6\u003cbr\u003eSafety standard: EN 61010-1 CAT III 600V, EN 61326-1\u003cbr\u003eAccessories: Instruction manual, Test leads, Batteries, Carry case, Hand strap\u003c\/p\u003e","brand":"Sperry","offers":[{"title":"Default Title","offer_id":32310275571809,"sku":"SW8052IN","price":189.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/8052-in.jpg?v=1590081682"},{"product_id":"aemc-6503","title":"AEMC 6503 – Hand-Crank Megohmmeter (1000V Analog Insulation Tester)","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"140\" data-end=\"211\" class=\"\"\u003e\u003cstrong data-start=\"140\" data-end=\"211\"\u003eAEMC 6503 Hand-Crank Megohmmeter – Rugged, Reliable, Ready Anywhere\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"213\" data-end=\"581\" class=\"\"\u003eThe AEMC 6503 is a durable, hand-cranked insulation resistance tester ideal for field use where power may not be available. With selectable test voltages of 250V, 500V, and 1000V, it delivers insulation resistance measurements up to 4000MΩ and also provides continuity checks up to 50Ω. A built-in voltmeter protects users by alerting them to live circuits up to 600V.\u003c\/p\u003e\n\u003cp data-start=\"583\" data-end=\"780\" class=\"\"\u003eDesigned for portability and simplicity, this analog megohmmeter is perfect for electricians, HVAC professionals, and industrial technicians who need dependable testing in challenging environments.\u003c\/p\u003e\n\u003cp data-start=\"782\" data-end=\"799\" class=\"\"\u003e\u003cstrong data-start=\"782\" data-end=\"799\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"800\" data-end=\"1114\"\u003e\n\u003cli data-start=\"800\" data-end=\"841\" class=\"\"\u003e\n\u003cp data-start=\"802\" data-end=\"841\" class=\"\"\u003eTest insulation resistance up to 4000MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"842\" data-end=\"890\" class=\"\"\u003e\n\u003cp data-start=\"844\" data-end=\"890\" class=\"\"\u003eManual crank operation – no batteries required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"891\" data-end=\"928\" class=\"\"\u003e\n\u003cp data-start=\"893\" data-end=\"928\" class=\"\"\u003eBuilt-in AC\/DC voltmeter up to 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"929\" data-end=\"980\" class=\"\"\u003e\n\u003cp data-start=\"931\" data-end=\"980\" class=\"\"\u003eThree selectable test voltages: 250V, 500V, 1000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"981\" data-end=\"1011\" class=\"\"\u003e\n\u003cp data-start=\"983\" data-end=\"1011\" class=\"\"\u003eContinuity testing up to 50Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1012\" data-end=\"1060\" class=\"\"\u003e\n\u003cp data-start=\"1014\" data-end=\"1060\" class=\"\"\u003eRugged construction for tough field conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1061\" data-end=\"1114\" class=\"\"\u003e\n\u003cp data-start=\"1063\" data-end=\"1114\" class=\"\"\u003eIncludes test leads, carrying case, and user manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1116\" data-end=\"1133\" class=\"\"\u003e\u003cstrong data-start=\"1116\" data-end=\"1133\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1134\" data-end=\"1259\"\u003e\n\u003cli data-start=\"1134\" data-end=\"1167\" class=\"\"\u003e\n\u003cp data-start=\"1136\" data-end=\"1167\" class=\"\"\u003eMotor and generator maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1168\" data-end=\"1199\" class=\"\"\u003e\n\u003cp data-start=\"1170\" data-end=\"1199\" class=\"\"\u003eIndustrial insulation testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1200\" data-end=\"1230\" class=\"\"\u003e\n\u003cp data-start=\"1202\" data-end=\"1230\" class=\"\"\u003eElectrical safety compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1231\" data-end=\"1259\" class=\"\"\u003e\n\u003cp data-start=\"1233\" data-end=\"1259\" class=\"\"\u003ePower distribution systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":39448524947649,"sku":"AEMC6503","price":880.23,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/products\/hand-cranked-megohmmeter-2126-52.png?v=1616174340"},{"product_id":"aemc-6529","title":"AEMC 6529 Handheld Digital Insulation Resistance Tester – 250V, 500V, 1000V","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"434\" data-end=\"695\"\u003eThe AEMC® 6529 is a compact, easy-to-use digital insulation tester designed for field technicians and plant electricians. It provides insulation resistance measurements at 250V, 500V, and 1000V test voltages—ideal for troubleshooting and preventive maintenance.\u003c\/p\u003e\n\u003chr data-start=\"697\" data-end=\"700\"\u003e\n\u003ch3 data-start=\"702\" data-end=\"721\"\u003e✅ Key Features:\u003c\/h3\u003e\n\u003cul data-start=\"722\" data-end=\"1022\"\u003e\n\u003cli data-start=\"722\" data-end=\"781\"\u003e\n\u003cp data-start=\"724\" data-end=\"781\"\u003eThree insulation test voltages: \u003cstrong data-start=\"756\" data-end=\"781\"\u003e250V, 500V, and 1000V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"782\" data-end=\"818\"\u003e\n\u003cp data-start=\"784\" data-end=\"818\"\u003eResistance range up to \u003cstrong data-start=\"807\" data-end=\"818\"\u003e4000 MΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"819\" data-end=\"896\"\u003e\n\u003cp data-start=\"821\" data-end=\"896\"\u003eBuilt-in \u003cstrong data-start=\"830\" data-end=\"851\"\u003evoltage detection\u003c\/strong\u003e prevents accidental testing on live circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"897\" data-end=\"954\"\u003e\n\u003cp data-start=\"899\" data-end=\"954\"\u003eBright backlit display with digital and analog bargraph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"955\" data-end=\"994\"\u003e\n\u003cp data-start=\"957\" data-end=\"994\"\u003eMeasures \u003cstrong data-start=\"966\" data-end=\"983\"\u003eAC\/DC voltage\u003c\/strong\u003e up to 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"995\" data-end=\"1022\"\u003e\n\u003cp data-start=\"997\" data-end=\"1022\"\u003eCAT IV 600V safety rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1024\" data-end=\"1027\"\u003e\n\u003ch3 data-start=\"1029\" data-end=\"1052\"\u003e📦 What's Included:\u003c\/h3\u003e\n\u003cul data-start=\"1053\" data-end=\"1159\"\u003e\n\u003cli data-start=\"1053\" data-end=\"1082\"\u003e\n\u003cp data-start=\"1055\" data-end=\"1082\"\u003eAEMC 6529 insulation tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1083\" data-end=\"1126\"\u003e\n\u003cp data-start=\"1085\" data-end=\"1126\"\u003eRed\/black test leads with alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1127\" data-end=\"1145\"\u003e\n\u003cp data-start=\"1129\" data-end=\"1145\"\u003e(6) AA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1146\" data-end=\"1159\"\u003e\n\u003cp data-start=\"1148\" data-end=\"1159\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1161\" data-end=\"1164\"\u003e\n\u003ch3 data-start=\"1166\" data-end=\"1186\"\u003e🧰 Applications:\u003c\/h3\u003e\n\u003cul data-start=\"1187\" data-end=\"1346\"\u003e\n\u003cli data-start=\"1187\" data-end=\"1256\"\u003e\n\u003cp data-start=\"1189\" data-end=\"1256\"\u003eTroubleshooting insulation faults in motors, cables, and switchgear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1257\" data-end=\"1302\"\u003e\n\u003cp data-start=\"1259\" data-end=\"1302\"\u003eRegular maintenance of industrial equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1303\" data-end=\"1346\"\u003e\n\u003cp data-start=\"1305\" data-end=\"1346\"\u003eElectrical commissioning and verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":49330040012993,"sku":"AEMC_2126.55","price":472.75,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/aemc-6529-digital-megohmmeter-2126-55.jpg?v=1749512552"},{"product_id":"aemc-6526","title":"AEMC 6526 Handheld Digital Insulation Resistance Tester – 50V to 1000V, Backlit Display, Auto Ranging","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"347\" data-end=\"700\"\u003eThe AEMC® 6526 is a lightweight, battery-powered digital insulation tester designed for maintenance professionals who need accurate, efficient testing in the field. It features \u003cstrong data-start=\"524\" data-end=\"572\"\u003efive selectable test voltages (50V to 1000V)\u003c\/strong\u003e, auto-ranging, and a bright backlit display—all in a compact handheld package built for industrial and commercial environments.\u003c\/p\u003e\n\u003chr data-start=\"702\" data-end=\"705\"\u003e\n\u003ch3 data-start=\"707\" data-end=\"726\"\u003e✅ Key Features:\u003c\/h3\u003e\n\u003cul data-start=\"727\" data-end=\"1076\"\u003e\n\u003cli data-start=\"727\" data-end=\"787\"\u003e\n\u003cp data-start=\"729\" data-end=\"787\"\u003e\u003cstrong data-start=\"729\" data-end=\"757\"\u003eSelectable test voltages\u003c\/strong\u003e: 50V, 100V, 250V, 500V, 1000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"788\" data-end=\"829\"\u003e\n\u003cp data-start=\"790\" data-end=\"829\"\u003e\u003cstrong data-start=\"790\" data-end=\"829\"\u003eInsulation resistance up to 4000 MΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"830\" data-end=\"894\"\u003e\n\u003cp data-start=\"832\" data-end=\"894\"\u003eAutomatically detects and displays \u003cstrong data-start=\"867\" data-end=\"883\"\u003elive voltage\u003c\/strong\u003e up to 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"895\" data-end=\"951\"\u003e\n\u003cp data-start=\"897\" data-end=\"951\"\u003eDual display: digital readout + analog-style bargraph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"952\" data-end=\"1007\"\u003e\n\u003cp data-start=\"954\" data-end=\"1007\"\u003eMeasures \u003cstrong data-start=\"963\" data-end=\"980\"\u003eAC\/DC voltage\u003c\/strong\u003e and continuity with buzzer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1008\" data-end=\"1044\"\u003e\n\u003cp data-start=\"1010\" data-end=\"1044\"\u003eAuto power-off to conserve battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1045\" data-end=\"1076\"\u003e\n\u003cp data-start=\"1047\" data-end=\"1076\"\u003e\u003cstrong data-start=\"1047\" data-end=\"1076\"\u003eCAT IV 600V safety rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1078\" data-end=\"1081\"\u003e\n\u003ch3 data-start=\"1083\" data-end=\"1106\"\u003e📦 What’s Included:\u003c\/h3\u003e\n\u003cul data-start=\"1107\" data-end=\"1233\"\u003e\n\u003cli data-start=\"1107\" data-end=\"1136\"\u003e\n\u003cp data-start=\"1109\" data-end=\"1136\"\u003eAEMC 6526 insulation tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1137\" data-end=\"1184\"\u003e\n\u003cp data-start=\"1139\" data-end=\"1184\"\u003eRed and black test leads with alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1185\" data-end=\"1200\"\u003e\n\u003cp data-start=\"1187\" data-end=\"1200\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1201\" data-end=\"1219\"\u003e\n\u003cp data-start=\"1203\" data-end=\"1219\"\u003e(6) AA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1220\" data-end=\"1233\"\u003e\n\u003cp data-start=\"1222\" data-end=\"1233\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1235\" data-end=\"1238\"\u003e\n\u003ch3 data-start=\"1240\" data-end=\"1260\"\u003e🧰 Applications:\u003c\/h3\u003e\n\u003cul data-start=\"1261\" data-end=\"1487\"\u003e\n\u003cli data-start=\"1261\" data-end=\"1331\"\u003e\n\u003cp data-start=\"1263\" data-end=\"1331\"\u003eMaintenance and testing of motors, switchgear, and electrical panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1332\" data-end=\"1368\"\u003e\n\u003cp data-start=\"1334\" data-end=\"1368\"\u003ePre-commissioning insulation tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1369\" data-end=\"1408\"\u003e\n\u003cp data-start=\"1371\" data-end=\"1408\"\u003eIndustrial electrical troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1409\" data-end=\"1487\"\u003e\n\u003cp data-start=\"1411\" data-end=\"1487\"\u003eIdeal for technicians and contractors working in utilities and manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":49330055676097,"sku":"AEMC 2155.53","price":1300.94,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/megohmmeter-2155-53.png?v=1749513053"},{"product_id":"aemc-5070","title":"AEMC 5070 5kV Digital\/Analog Megohmmeter – Programmable Insulation Tester with USB \u0026 RS-232","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"345\" data-end=\"713\"\u003eThe AEMC® 5070 is a powerful, field-rugged \u003cstrong data-start=\"388\" data-end=\"422\"\u003e5kV digital\/analog megohmmeter\u003c\/strong\u003e designed for advanced insulation resistance testing. With \u003cstrong data-start=\"481\" data-end=\"523\"\u003eprogrammable test voltages up to 5100V\u003c\/strong\u003e, built-in data storage, and USB\/RS-232 interfaces, it’s the ideal solution for utilities, industrial maintenance teams, and OEMs requiring high-voltage insulation tests with full reporting.\u003c\/p\u003e\n\u003chr data-start=\"715\" data-end=\"718\"\u003e\n\u003ch3 data-start=\"720\" data-end=\"739\"\u003e✅ Key Features:\u003c\/h3\u003e\n\u003cul data-start=\"740\" data-end=\"1127\"\u003e\n\u003cli data-start=\"740\" data-end=\"795\"\u003e\n\u003cp data-start=\"742\" data-end=\"795\"\u003e\u003cstrong data-start=\"742\" data-end=\"777\"\u003eTest voltages from 40V to 5100V\u003c\/strong\u003e in 10V increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"796\" data-end=\"848\"\u003e\n\u003cp data-start=\"798\" data-end=\"848\"\u003eInsulation resistance measurements up to \u003cstrong data-start=\"839\" data-end=\"848\"\u003e10 TΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"849\" data-end=\"897\"\u003e\n\u003cp data-start=\"851\" data-end=\"897\"\u003eProgrammable PI, DAR, and Step Voltage testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"898\" data-end=\"946\"\u003e\n\u003cp data-start=\"900\" data-end=\"946\"\u003e\u003cstrong data-start=\"900\" data-end=\"928\"\u003eUSB and RS-232 interface\u003c\/strong\u003e for data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"947\" data-end=\"1001\"\u003e\n\u003cp data-start=\"949\" data-end=\"1001\"\u003eStores up to \u003cstrong data-start=\"962\" data-end=\"990\"\u003e64 complete test results\u003c\/strong\u003e internally\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1002\" data-end=\"1053\"\u003e\n\u003cp data-start=\"1004\" data-end=\"1053\"\u003eLarge digital display with backlight + analog arc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1054\" data-end=\"1095\"\u003e\n\u003cp data-start=\"1056\" data-end=\"1095\"\u003eRechargeable NiMH battery or AC powered\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1096\" data-end=\"1127\"\u003e\n\u003cp data-start=\"1098\" data-end=\"1127\"\u003e\u003cstrong data-start=\"1098\" data-end=\"1127\"\u003eCAT IV 600V safety rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1129\" data-end=\"1132\"\u003e\n\u003ch3 data-start=\"1134\" data-end=\"1157\"\u003e📦 What’s Included:\u003c\/h3\u003e\n\u003cul data-start=\"1158\" data-end=\"1345\"\u003e\n\u003cli data-start=\"1158\" data-end=\"1181\"\u003e\n\u003cp data-start=\"1160\" data-end=\"1181\"\u003eAEMC 5070 megohmmeter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1182\" data-end=\"1231\"\u003e\n\u003cp data-start=\"1184\" data-end=\"1231\"\u003e(2) color-coded test leads with alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1232\" data-end=\"1275\"\u003e\n\u003cp data-start=\"1234\" data-end=\"1275\"\u003e(1) shielded test lead for guard terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1276\" data-end=\"1300\"\u003e\n\u003cp data-start=\"1278\" data-end=\"1300\"\u003eUSB cable and software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1301\" data-end=\"1345\"\u003e\n\u003cp data-start=\"1303\" data-end=\"1345\"\u003ePower cord, user manual, and carrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1347\" data-end=\"1350\"\u003e\n\u003ch3 data-start=\"1352\" data-end=\"1372\"\u003e🧰 Applications:\u003c\/h3\u003e\n\u003cul data-start=\"1373\" data-end=\"1579\"\u003e\n\u003cli data-start=\"1373\" data-end=\"1451\"\u003e\n\u003cp data-start=\"1375\" data-end=\"1451\"\u003eHigh-voltage insulation resistance testing in motors, cables, and switchgear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1452\" data-end=\"1497\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1497\"\u003eUtility and industrial maintenance programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1498\" data-end=\"1534\"\u003e\n\u003cp data-start=\"1500\" data-end=\"1534\"\u003eAcceptance and commissioning tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1535\" data-end=\"1579\"\u003e\n\u003cp data-start=\"1537\" data-end=\"1579\"\u003eAutomated test documentation and archiving\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":49330062164161,"sku":"AEMC 2130.30","price":6366.2,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/megohmmeter-2130-30.png?v=1749513491"},{"product_id":"aemc-1015","title":"AEMC 1015 Compact Insulation Resistance Tester – 250V, 500V, 1000V","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"319\" data-end=\"613\"\u003eThe AEMC® 1015 is a rugged, compact insulation tester designed for everyday use in the field. With selectable test voltages (250V, 500V, 1000V), it’s ideal for troubleshooting and preventative maintenance of motors, wiring, and equipment in industrial, commercial, and residential environments.\u003c\/p\u003e\n\u003cp data-start=\"615\" data-end=\"765\"\u003eBuilt tough and easy to use, the 1015 is perfect for electricians, HVAC techs, and anyone who needs reliable insulation resistance readings on the go.\u003c\/p\u003e\n\u003chr data-start=\"767\" data-end=\"770\"\u003e\n\u003ch3 data-start=\"772\" data-end=\"791\"\u003e✅ Key Features:\u003c\/h3\u003e\n\u003cul data-start=\"792\" data-end=\"1104\"\u003e\n\u003cli data-start=\"792\" data-end=\"845\"\u003e\n\u003cp data-start=\"794\" data-end=\"845\"\u003eSelectable test voltages: \u003cstrong data-start=\"820\" data-end=\"845\"\u003e250V, 500V, and 1000V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"846\" data-end=\"896\"\u003e\n\u003cp data-start=\"848\" data-end=\"896\"\u003eMeasures insulation resistance up to \u003cstrong data-start=\"885\" data-end=\"896\"\u003e2000 MΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"897\" data-end=\"945\"\u003e\n\u003cp data-start=\"899\" data-end=\"945\"\u003eAlso measures \u003cstrong data-start=\"913\" data-end=\"930\"\u003eAC\/DC voltage\u003c\/strong\u003e and continuity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"946\" data-end=\"1001\"\u003e\n\u003cp data-start=\"948\" data-end=\"1001\"\u003eLarge easy-to-read display with analog-style bargraph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1002\" data-end=\"1045\"\u003e\n\u003cp data-start=\"1004\" data-end=\"1045\"\u003eCompact, lightweight design for field use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1046\" data-end=\"1071\"\u003e\n\u003cp data-start=\"1048\" data-end=\"1071\"\u003eAuto power-off function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1072\" data-end=\"1104\"\u003e\n\u003cp data-start=\"1074\" data-end=\"1104\"\u003e\u003cstrong data-start=\"1074\" data-end=\"1104\"\u003eCAT III 600V safety rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1106\" data-end=\"1109\"\u003e\n\u003ch3 data-start=\"1111\" data-end=\"1134\"\u003e📦 What’s Included:\u003c\/h3\u003e\n\u003cul data-start=\"1135\" data-end=\"1257\"\u003e\n\u003cli data-start=\"1135\" data-end=\"1164\"\u003e\n\u003cp data-start=\"1137\" data-end=\"1164\"\u003eAEMC 1015 insulation tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1165\" data-end=\"1208\"\u003e\n\u003cp data-start=\"1167\" data-end=\"1208\"\u003eRed\/black test leads with alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1209\" data-end=\"1227\"\u003e\n\u003cp data-start=\"1211\" data-end=\"1227\"\u003e(6) AA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1228\" data-end=\"1241\"\u003e\n\u003cp data-start=\"1230\" data-end=\"1241\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1242\" data-end=\"1257\"\u003e\n\u003cp data-start=\"1244\" data-end=\"1257\"\u003eCarrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1259\" data-end=\"1262\"\u003e\n\u003ch3 data-start=\"1264\" data-end=\"1284\"\u003e🧰 Applications:\u003c\/h3\u003e\n\u003cul data-start=\"1285\" data-end=\"1509\"\u003e\n\u003cli data-start=\"1285\" data-end=\"1346\"\u003e\n\u003cp data-start=\"1287\" data-end=\"1346\"\u003eTroubleshooting insulation problems in motors and equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1347\" data-end=\"1388\"\u003e\n\u003cp data-start=\"1349\" data-end=\"1388\"\u003eBasic maintenance of electrical systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1389\" data-end=\"1460\"\u003e\n\u003cp data-start=\"1391\" data-end=\"1460\"\u003eTesting wiring insulation in residential and commercial installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1461\" data-end=\"1509\"\u003e\n\u003cp data-start=\"1463\" data-end=\"1509\"\u003eIdeal for HVAC and field service professional\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":49330064556225,"sku":"AEMC 1403.01","price":1228.61,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/megohmmeter-1403-01.png?v=1749513929"},{"product_id":"aemc-6534","title":"AEMC 6534 Digital Megohmmeter – 1000V, Rechargeable, with Locking Test Leads","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"318\" data-end=\"685\"\u003eThe AEMC® 6534 is a rugged, handheld \u003cstrong data-start=\"355\" data-end=\"393\"\u003e1000V insulation resistance tester\u003c\/strong\u003e designed for demanding environments. With a rechargeable battery, built-in AC\/DC voltmeter, and locking test leads for operator safety, the 6534 is ideal for utility technicians, field engineers, and electrical maintenance teams who need reliable, safe, and accurate insulation measurements.\u003c\/p\u003e\n\u003cp data-start=\"687\" data-end=\"862\"\u003eThis model offers intuitive controls, fast stabilization, and a CAT IV 600V safety rating, making it a go-to choice for insulation testing in real-world industrial conditions.\u003c\/p\u003e\n\u003chr data-start=\"864\" data-end=\"867\"\u003e\n\u003ch3 data-start=\"869\" data-end=\"888\"\u003e✅ Key Features:\u003c\/h3\u003e\n\u003cul data-start=\"889\" data-end=\"1295\"\u003e\n\u003cli data-start=\"889\" data-end=\"914\"\u003e\n\u003cp data-start=\"891\" data-end=\"914\"\u003eTest voltage: \u003cstrong data-start=\"905\" data-end=\"914\"\u003e1000V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"915\" data-end=\"956\"\u003e\n\u003cp data-start=\"917\" data-end=\"956\"\u003eInsulation resistance up to \u003cstrong data-start=\"945\" data-end=\"956\"\u003e2000 MΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"996\"\u003e\n\u003cp data-start=\"959\" data-end=\"996\"\u003eMeasures \u003cstrong data-start=\"968\" data-end=\"985\"\u003eAC\/DC voltage\u003c\/strong\u003e up to 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"997\" data-end=\"1038\"\u003e\n\u003cp data-start=\"999\" data-end=\"1038\"\u003eAudible and visual \u003cstrong data-start=\"1018\" data-end=\"1038\"\u003econtinuity check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1039\" data-end=\"1084\"\u003e\n\u003cp data-start=\"1041\" data-end=\"1084\"\u003eRechargeable NiMH battery with long runtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1085\" data-end=\"1154\"\u003e\n\u003cp data-start=\"1087\" data-end=\"1154\"\u003e\u003cstrong data-start=\"1087\" data-end=\"1109\"\u003eLocking test leads\u003c\/strong\u003e for added safety during high-voltage testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1155\" data-end=\"1212\"\u003e\n\u003cp data-start=\"1157\" data-end=\"1212\"\u003eEasy-to-read digital display with analog-style bargraph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1213\" data-end=\"1263\"\u003e\n\u003cp data-start=\"1215\" data-end=\"1263\"\u003eRugged housing with integrated test lead storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1264\" data-end=\"1295\"\u003e\n\u003cp data-start=\"1266\" data-end=\"1295\"\u003e\u003cstrong data-start=\"1266\" data-end=\"1295\"\u003eCAT IV 600V safety rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1297\" data-end=\"1300\"\u003e\n\u003ch3 data-start=\"1302\" data-end=\"1325\"\u003e📦 What’s Included:\u003c\/h3\u003e\n\u003cul data-start=\"1326\" data-end=\"1493\"\u003e\n\u003cli data-start=\"1326\" data-end=\"1355\"\u003e\n\u003cp data-start=\"1328\" data-end=\"1355\"\u003eAEMC 6534 insulation tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1356\" data-end=\"1407\"\u003e\n\u003cp data-start=\"1358\" data-end=\"1407\"\u003eLocking red\/black test leads with alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1408\" data-end=\"1437\"\u003e\n\u003cp data-start=\"1410\" data-end=\"1437\"\u003eRechargeable battery (NiMH)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1438\" data-end=\"1461\"\u003e\n\u003cp data-start=\"1440\" data-end=\"1461\"\u003eCharger\/power adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1462\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1464\" data-end=\"1493\"\u003eUser manual and carrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1495\" data-end=\"1498\"\u003e\n\u003ch3 data-start=\"1500\" data-end=\"1520\"\u003e🧰 Applications:\u003c\/h3\u003e\n\u003cul data-start=\"1521\" data-end=\"1782\"\u003e\n\u003cli data-start=\"1521\" data-end=\"1594\"\u003e\n\u003cp data-start=\"1523\" data-end=\"1594\"\u003eMaintenance and troubleshooting of motors, transformers, and switchgear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1595\" data-end=\"1648\"\u003e\n\u003cp data-start=\"1597\" data-end=\"1648\"\u003eField testing in power utilities and heavy industry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1649\" data-end=\"1696\"\u003e\n\u003cp data-start=\"1651\" data-end=\"1696\"\u003ePre-commissioning insulation resistance tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1697\" data-end=\"1782\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1782\"\u003eTechnicians seeking \u003cstrong data-start=\"1719\" data-end=\"1727\"\u003esafe\u003c\/strong\u003e, \u003cstrong data-start=\"1729\" data-end=\"1741\"\u003eportable\u003c\/strong\u003e, and \u003cstrong data-start=\"1747\" data-end=\"1763\"\u003erechargeable\u003c\/strong\u003e insulation testers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":49330068357313,"sku":"AEMC 2155.55","price":1467.63,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/megohmmeter-2155-55.png?v=1749514308"},{"product_id":"aemc-6536","title":"AEMC 6536 Digital Megohmmeter – 250V to 1000V, Rechargeable, Industrial-Grade Insulation Tester","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"361\" data-end=\"683\"\u003eThe AEMC® 6536 is a \u003cstrong data-start=\"381\" data-end=\"438\"\u003ehigh-performance digital insulation resistance tester\u003c\/strong\u003e with selectable test voltages from \u003cstrong data-start=\"474\" data-end=\"491\"\u003e250V to 1000V\u003c\/strong\u003e, designed for industrial, utility, and field service professionals. Built with safety in mind, it includes \u003cstrong data-start=\"599\" data-end=\"621\"\u003elocking test leads\u003c\/strong\u003e, \u003cstrong data-start=\"623\" data-end=\"652\"\u003erechargeable NiMH battery\u003c\/strong\u003e, and a \u003cstrong data-start=\"660\" data-end=\"675\"\u003eCAT IV 600V\u003c\/strong\u003e rating.\u003c\/p\u003e\n\u003cp data-start=\"685\" data-end=\"847\"\u003eIt combines durability, ease of use, and dependable accuracy in a handheld package—perfect for insulation testing in motors, switchgear, control panels, and more.\u003c\/p\u003e\n\u003chr data-start=\"849\" data-end=\"852\"\u003e\n\u003ch3 data-start=\"854\" data-end=\"873\"\u003e✅ Key Features:\u003c\/h3\u003e\n\u003cul data-start=\"874\" data-end=\"1269\"\u003e\n\u003cli data-start=\"874\" data-end=\"923\"\u003e\n\u003cp data-start=\"876\" data-end=\"923\"\u003e\u003cstrong data-start=\"876\" data-end=\"904\"\u003eSelectable test voltages\u003c\/strong\u003e: 250V, 500V, 1000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"924\" data-end=\"965\"\u003e\n\u003cp data-start=\"926\" data-end=\"965\"\u003eInsulation resistance up to \u003cstrong data-start=\"954\" data-end=\"965\"\u003e2000 MΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"966\" data-end=\"1005\"\u003e\n\u003cp data-start=\"968\" data-end=\"1005\"\u003eMeasures \u003cstrong data-start=\"977\" data-end=\"994\"\u003eAC\/DC voltage\u003c\/strong\u003e up to 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1006\" data-end=\"1042\"\u003e\n\u003cp data-start=\"1008\" data-end=\"1042\"\u003eAudible\/visual \u003cstrong data-start=\"1023\" data-end=\"1042\"\u003econtinuity test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1043\" data-end=\"1087\"\u003e\n\u003cp data-start=\"1045\" data-end=\"1087\"\u003e\u003cstrong data-start=\"1045\" data-end=\"1074\"\u003eRechargeable NiMH battery\u003c\/strong\u003e with charger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1088\" data-end=\"1144\"\u003e\n\u003cp data-start=\"1090\" data-end=\"1144\"\u003e\u003cstrong data-start=\"1090\" data-end=\"1112\"\u003eLocking test leads\u003c\/strong\u003e for safe high-voltage operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1145\" data-end=\"1192\"\u003e\n\u003cp data-start=\"1147\" data-end=\"1192\"\u003eDual display: digital + analog-style bargraph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1193\" data-end=\"1237\"\u003e\n\u003cp data-start=\"1195\" data-end=\"1237\"\u003eRobust design with integrated lead storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1238\" data-end=\"1269\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1269\"\u003e\u003cstrong data-start=\"1240\" data-end=\"1269\"\u003eCAT IV 600V safety rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1271\" data-end=\"1274\"\u003e\n\u003ch3 data-start=\"1276\" data-end=\"1299\"\u003e📦 What’s Included:\u003c\/h3\u003e\n\u003cul data-start=\"1300\" data-end=\"1463\"\u003e\n\u003cli data-start=\"1300\" data-end=\"1329\"\u003e\n\u003cp data-start=\"1302\" data-end=\"1329\"\u003eAEMC 6536 insulation tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1330\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1332\" data-end=\"1371\"\u003eLocking test leads with alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1372\" data-end=\"1399\"\u003e\n\u003cp data-start=\"1374\" data-end=\"1399\"\u003eNiMH rechargeable battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1400\" data-end=\"1431\"\u003e\n\u003cp data-start=\"1402\" data-end=\"1431\"\u003eBattery charger\/power adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1432\" data-end=\"1463\"\u003e\n\u003cp data-start=\"1434\" data-end=\"1463\"\u003eUser manual and carrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1465\" data-end=\"1468\"\u003e\n\u003ch3 data-start=\"1470\" data-end=\"1490\"\u003e🧰 Applications:\u003c\/h3\u003e\n\u003cul data-start=\"1491\" data-end=\"1718\"\u003e\n\u003cli data-start=\"1491\" data-end=\"1542\"\u003e\n\u003cp data-start=\"1493\" data-end=\"1542\"\u003eField testing of motors, transformers, and cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1543\" data-end=\"1577\"\u003e\n\u003cp data-start=\"1545\" data-end=\"1577\"\u003eScheduled preventive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1578\" data-end=\"1625\"\u003e\n\u003cp data-start=\"1580\" data-end=\"1625\"\u003eIndustrial and utility electrical diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1626\" data-end=\"1718\"\u003e\n\u003cp data-start=\"1628\" data-end=\"1718\"\u003eIdeal for electricians and technicians requiring portable, rechargeable insulation testers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":49330072289473,"sku":"AEMC 2155.56","price":1466.75,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/megohmmeter-2155-56.png?v=1749514636"},{"product_id":"aemc-6522","title":"AEMC 6522 Digital Insulation Resistance Tester – 250V, 500V, 1000V","description":"\u003ch2 data-start=\"319\" data-end=\"613\"\u003e\u003cem\u003e\u003cstrong\u003eLimited-time offer: \u003cbr\u003eFree shipping while quantities last!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/h2\u003e\n\u003cp data-start=\"317\" data-end=\"667\"\u003eThe AEMC® 6522 is a \u003cstrong data-start=\"337\" data-end=\"376\"\u003eportable, digital insulation tester\u003c\/strong\u003e that delivers accurate and reliable measurements with simplicity. Offering three fixed test voltages (250V, 500V, 1000V), the 6522 is perfect for electricians and field service professionals performing routine insulation checks in residential, commercial, and light industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"669\" data-end=\"841\"\u003eDesigned for everyday reliability, the 6522 features a large backlit display, built-in voltage detection, and straightforward operation—all in a compact and rugged package.\u003c\/p\u003e\n\u003chr data-start=\"843\" data-end=\"846\"\u003e\n\u003ch3 data-start=\"848\" data-end=\"867\"\u003e✅ Key Features:\u003c\/h3\u003e\n\u003cul data-start=\"868\" data-end=\"1222\"\u003e\n\u003cli data-start=\"868\" data-end=\"910\"\u003e\n\u003cp data-start=\"870\" data-end=\"910\"\u003eTest voltages: \u003cstrong data-start=\"885\" data-end=\"910\"\u003e250V, 500V, and 1000V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"911\" data-end=\"961\"\u003e\n\u003cp data-start=\"913\" data-end=\"961\"\u003eMeasures insulation resistance up to \u003cstrong data-start=\"950\" data-end=\"961\"\u003e2000 MΩ\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"962\" data-end=\"1023\"\u003e\n\u003cp data-start=\"964\" data-end=\"1023\"\u003eBuilt-in live voltage detection (alerts if \u0026gt;25V is present)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1024\" data-end=\"1063\"\u003e\n\u003cp data-start=\"1026\" data-end=\"1063\"\u003eMeasures \u003cstrong data-start=\"1035\" data-end=\"1052\"\u003eAC\/DC voltage\u003c\/strong\u003e up to 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1064\" data-end=\"1104\"\u003e\n\u003cp data-start=\"1066\" data-end=\"1104\"\u003eBacklit LCD with analog-style bargraph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1105\" data-end=\"1149\"\u003e\n\u003cp data-start=\"1107\" data-end=\"1149\"\u003eAutomatic test inhibition on live circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1150\" data-end=\"1190\"\u003e\n\u003cp data-start=\"1152\" data-end=\"1190\"\u003eCompact, durable housing for field use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1191\" data-end=\"1222\"\u003e\n\u003cp data-start=\"1193\" data-end=\"1222\"\u003e\u003cstrong data-start=\"1193\" data-end=\"1222\"\u003eCAT IV 600V safety rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1224\" data-end=\"1227\"\u003e\n\u003ch3 data-start=\"1229\" data-end=\"1252\"\u003e📦 What’s Included:\u003c\/h3\u003e\n\u003cul data-start=\"1253\" data-end=\"1377\"\u003e\n\u003cli data-start=\"1253\" data-end=\"1282\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1282\"\u003eAEMC 6522 insulation tester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1283\" data-end=\"1326\"\u003e\n\u003cp data-start=\"1285\" data-end=\"1326\"\u003eRed\/black test leads with alligator clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1327\" data-end=\"1345\"\u003e\n\u003cp data-start=\"1329\" data-end=\"1345\"\u003e(6) AA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1346\" data-end=\"1377\"\u003e\n\u003cp data-start=\"1348\" data-end=\"1377\"\u003eUser manual and carrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1379\" data-end=\"1382\"\u003e\n\u003ch3 data-start=\"1384\" data-end=\"1404\"\u003e🧰 Applications:\u003c\/h3\u003e\n\u003cul data-start=\"1405\" data-end=\"1620\"\u003e\n\u003cli data-start=\"1405\" data-end=\"1449\"\u003e\n\u003cp data-start=\"1407\" data-end=\"1449\"\u003eElectrical maintenance and troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1509\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1509\"\u003eInsulation testing on wiring, motors, and small equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1510\" data-end=\"1573\"\u003e\n\u003cp data-start=\"1512\" data-end=\"1573\"\u003eRoutine field checks by service professionals and contractors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1574\" data-end=\"1620\"\u003e\n\u003cp data-start=\"1576\" data-end=\"1620\"\u003eIdeal for general-purpose insulation testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AEMC","offers":[{"title":"Default Title","offer_id":49330079662273,"sku":"AEMC2155.51","price":1133.36,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/megohmmeter-2155-51.png?v=1749514935"},{"product_id":"kyoritsu-kew-3025b","title":"Kyoritsu KEW 3025B – Digital High-Voltage Insulation Tester (Up to 2.5 kV)","description":"\u003cp data-start=\"244\" data-end=\"327\"\u003e\u003cstrong data-start=\"200\" data-end=\"241\"\u003eUpgraded replacement for \u003cstrong data-start=\"357\" data-end=\"398\"\u003eUpgraded replacement for\u003ca href=\"https:\/\/duncaninstr.com\/products\/kyoritsu-3025a-digital-2-5kv-insulation-tester\"\u003e model 3025A\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cstrong data-start=\"200\" data-end=\"241\"\u003eKyoritsu KEW 3125B High Voltage Insulation Resistance Tester – 5kV, USB, CAT IV\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe KEW 3125B is a powerful \u003cstrong\u003e5kV insulation resistance tester \u003c\/strong\u003edesigned for professionals who demand reliable performance in high-voltage environments. It combines fast measurement, modern safety features, and a USB interface for easy data transfer—everything needed for industrial, utility, and commissioning work.\u003cbr data-start=\"241\" data-end=\"244\"\u003e\u003c\/p\u003e\n\u003cp data-start=\"748\" data-end=\"767\"\u003e\u003cstrong data-start=\"748\" data-end=\"765\"\u003eWhat it does:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"768\" data-end=\"993\"\u003e\n\u003cli data-start=\"768\" data-end=\"857\"\u003e\n\u003cp data-start=\"770\" data-end=\"857\"\u003eMeasures insulation resistance up to 1 TΩ with selectable test voltages (500V to 5kV)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"858\" data-end=\"936\"\u003e\n\u003cp data-start=\"860\" data-end=\"936\"\u003eProvides reliable results for cables, transformers, motors, and switchgear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"937\" data-end=\"993\"\u003e\n\u003cp data-start=\"939\" data-end=\"993\"\u003eIncludes USB communication for logging and reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"995\" data-end=\"1014\"\u003e\u003cstrong data-start=\"995\" data-end=\"1012\"\u003eWho it's for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1015\" data-end=\"1148\"\u003e\n\u003cli data-start=\"1015\" data-end=\"1041\"\u003e\n\u003cp data-start=\"1017\" data-end=\"1041\"\u003eElectrical contractors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1074\"\u003e\n\u003cp data-start=\"1044\" data-end=\"1074\"\u003eIndustrial maintenance teams\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1075\" data-end=\"1114\"\u003e\n\u003cp data-start=\"1077\" data-end=\"1114\"\u003eUtility and commissioning engineers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1115\" data-end=\"1148\"\u003e\n\u003cp data-start=\"1117\" data-end=\"1148\"\u003eAnyone upgrading from KEW 3025A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1150\" data-end=\"1172\"\u003e\u003cstrong data-start=\"1150\" data-end=\"1170\"\u003eWhy it's better:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1173\" data-end=\"1358\"\u003e\n\u003cli data-start=\"1173\" data-end=\"1206\"\u003e\n\u003cp data-start=\"1175\" data-end=\"1206\"\u003eImproved measurement accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1207\" data-end=\"1245\"\u003e\n\u003cp data-start=\"1209\" data-end=\"1245\"\u003eModern safety design (CAT IV 600V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1246\" data-end=\"1284\"\u003e\n\u003cp data-start=\"1248\" data-end=\"1284\"\u003eAuto-discharge and timer functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1308\"\u003e\n\u003cp data-start=\"1287\" data-end=\"1308\"\u003eUSB output standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1309\" data-end=\"1358\"\u003e\n\u003cp data-start=\"1311\" data-end=\"1358\"\u003eEnhanced screen readability and faster response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1360\" data-end=\"1363\"\u003e\n\u003ch3 data-start=\"1365\" data-end=\"1396\"\u003e✅ Technical Specifications:\u003c\/h3\u003e\n\u003cul data-start=\"1397\" data-end=\"1790\"\u003e\n\u003cli data-start=\"1397\" data-end=\"1448\"\u003e\n\u003cp data-start=\"1399\" data-end=\"1448\"\u003e\u003cstrong data-start=\"1399\" data-end=\"1416\"\u003eTest Voltages\u003c\/strong\u003e: 500V \/ 1000V \/ 2500V \/ 5000V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1449\" data-end=\"1501\"\u003e\n\u003cp data-start=\"1451\" data-end=\"1501\"\u003e\u003cstrong data-start=\"1451\" data-end=\"1482\"\u003eInsulation Resistance Range\u003c\/strong\u003e: 0.01 MΩ to 1 TΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1502\" data-end=\"1543\"\u003e\n\u003cp data-start=\"1504\" data-end=\"1543\"\u003e\u003cstrong data-start=\"1504\" data-end=\"1529\"\u003eShort-Circuit Current\u003c\/strong\u003e: 1.5 mA max\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1544\" data-end=\"1588\"\u003e\n\u003cp data-start=\"1546\" data-end=\"1588\"\u003e\u003cstrong data-start=\"1546\" data-end=\"1557\"\u003eDisplay\u003c\/strong\u003e: Dual digital with bar graph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1589\" data-end=\"1645\"\u003e\n\u003cp data-start=\"1591\" data-end=\"1645\"\u003e\u003cstrong data-start=\"1591\" data-end=\"1607\"\u003ePower Supply\u003c\/strong\u003e: Rechargeable battery or AC adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1646\" data-end=\"1692\"\u003e\n\u003cp data-start=\"1648\" data-end=\"1692\"\u003e\u003cstrong data-start=\"1648\" data-end=\"1665\"\u003eSafety Rating\u003c\/strong\u003e: IEC 61010-1 CAT IV 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1693\" data-end=\"1717\"\u003e\n\u003cp data-start=\"1695\" data-end=\"1717\"\u003e\u003cstrong data-start=\"1695\" data-end=\"1710\"\u003eData Output\u003c\/strong\u003e: USB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1718\" data-end=\"1790\"\u003e\n\u003cp data-start=\"1720\" data-end=\"1790\"\u003e\u003cstrong data-start=\"1720\" data-end=\"1735\"\u003eAccessories\u003c\/strong\u003e: Test leads, alligator clips, carrying case, USB cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFull specifications and manuals available from the manufacturer:\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/01344\/\" target=\"_blank\" rel=\"noopener\"\u003eKyoritsu KEW 3205B on KEW Japan website (in English)\u003c\/a\u003e\u003c\/p\u003e","brand":"Kyoritsu","offers":[{"title":"Default Title","offer_id":49457219666113,"sku":"KEW3025A","price":1554.28,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/unnamed_190e1b82-d082-4b7f-98e9-3168696d8525.jpg?v=1754613689"},{"product_id":"mi-3211","title":"MI 3211 TeraOhmHP 10 kV","description":"\u003ch1 data-start=\"299\" data-end=\"397\"\u003eMetrel MI 3211 TeraOhmHP 10 kV High Voltage Insulation Tester\u003c\/h1\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ch3 data-start=\"323\" data-end=\"396\"\u003ePush your insulation testing further — up to 10 kV with confidence.\u003c\/h3\u003e\n\u003cp data-start=\"398\" data-end=\"763\"\u003eThe \u003cstrong\u003eMetrel MI 3211 TeraOhmHP 10 kV\u003c\/strong\u003e is designed for professionals who need \u003cstrong data-start=\"472\" data-end=\"517\"\u003ereliable, high-voltage insulation testing\u003c\/strong\u003e in power generation, transmission, distribution, and heavy industry. Whether you’re verifying insulation on motors, generators, transformers, or high-voltage cables, the MI 3211 delivers \u003cstrong data-start=\"705\" data-end=\"742\"\u003eprecision, durability, and safety\u003c\/strong\u003e in one instrument.\u003c\/p\u003e\n\u003chr data-start=\"765\" data-end=\"768\"\u003e\n\u003ch2 data-start=\"770\" data-end=\"793\"\u003e\u003cstrong data-start=\"773\" data-end=\"793\"\u003eWhat does it do?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"794\" data-end=\"1038\"\u003eThe MI 3211 measures insulation resistance up to \u003cstrong data-start=\"843\" data-end=\"889\"\u003e30 TΩ at test voltages from 250 V to 10 kV\u003c\/strong\u003e. It provides accurate diagnostics of insulation integrity, helping prevent failures, reduce downtime, and ensure compliance with safety standards.\u003c\/p\u003e\n\u003ch2 data-start=\"1040\" data-end=\"1061\"\u003e\u003cstrong data-start=\"1043\" data-end=\"1061\"\u003eWho is it for?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1062\" data-end=\"1269\"\u003e\n\u003cli data-start=\"1062\" data-end=\"1110\"\u003e\n\u003cp data-start=\"1064\" data-end=\"1110\"\u003eElectrical contractors and utility engineers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1111\" data-end=\"1143\"\u003e\n\u003cp data-start=\"1113\" data-end=\"1143\"\u003eIndustrial maintenance teams\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1171\"\u003e\n\u003cp data-start=\"1146\" data-end=\"1171\"\u003ePower plant technicians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1172\" data-end=\"1269\"\u003e\n\u003cp data-start=\"1174\" data-end=\"1269\"\u003eAnyone working with medium- and high-voltage equipment requiring \u003cstrong data-start=\"1239\" data-end=\"1267\"\u003e10 kV insulation testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1271\" data-end=\"1295\"\u003e\u003cstrong data-start=\"1274\" data-end=\"1295\"\u003eWhy is it better?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1296\" data-end=\"1362\"\u003eCompared to older models (like the MI 3210), the MI 3211 offers:\u003c\/p\u003e\n\u003cul data-start=\"1363\" data-end=\"1744\"\u003e\n\u003cli data-start=\"1363\" data-end=\"1443\"\u003e\n\u003cp data-start=\"1365\" data-end=\"1443\"\u003e\u003cstrong data-start=\"1365\" data-end=\"1394\"\u003eHigher test voltage range\u003c\/strong\u003e (up to 10 kV) for greater application coverage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1444\" data-end=\"1502\"\u003e\n\u003cp data-start=\"1446\" data-end=\"1502\"\u003e\u003cstrong data-start=\"1446\" data-end=\"1478\"\u003eCAT IV \/ 600 V safety rating\u003c\/strong\u003e for robust protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1503\" data-end=\"1577\"\u003e\n\u003cp data-start=\"1505\" data-end=\"1577\"\u003eLarge \u003cstrong data-start=\"1511\" data-end=\"1534\"\u003eLCD graphic display\u003c\/strong\u003e with real-time test progress and results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1578\" data-end=\"1685\"\u003e\n\u003cp data-start=\"1580\" data-end=\"1685\"\u003eAdvanced features: \u003cstrong\u003epolarization index (PI), dielectric absorption ratio (DAR), step voltage, ramp tests\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1686\" data-end=\"1744\"\u003e\n\u003cp data-start=\"1688\" data-end=\"1744\"\u003e\u003cstrong data-start=\"1688\" data-end=\"1719\"\u003eRechargeable Li-ion battery\u003c\/strong\u003e for extended field use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1746\" data-end=\"1749\"\u003e\n\u003ch2 data-start=\"1751\" data-end=\"1786\"\u003e\u003cstrong data-start=\"1754\" data-end=\"1786\"\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1787\" data-end=\"2328\"\u003e\n\u003cli data-start=\"1787\" data-end=\"1854\"\u003e\n\u003cp data-start=\"1789\" data-end=\"1854\"\u003e\u003cstrong data-start=\"1789\" data-end=\"1812\"\u003eTest voltage range:\u003c\/strong\u003e 250 V – 10 kV, adjustable in 50 V steps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1855\" data-end=\"1897\"\u003e\n\u003cp data-start=\"1857\" data-end=\"1897\"\u003e\u003cstrong data-start=\"1857\" data-end=\"1883\"\u003eInsulation resistance:\u003c\/strong\u003e up to 30 TΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1898\" data-end=\"1933\"\u003e\n\u003cp data-start=\"1900\" data-end=\"1933\"\u003e\u003cstrong data-start=\"1900\" data-end=\"1926\"\u003eShort-circuit current:\u003c\/strong\u003e 5 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1934\" data-end=\"2033\"\u003e\n\u003cp data-start=\"1936\" data-end=\"2033\"\u003e\u003cstrong data-start=\"1936\" data-end=\"1962\"\u003eMeasurement functions:\u003c\/strong\u003e RISO, DAR, PI, step voltage, ramp test, capacitance, leakage current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2034\" data-end=\"2079\"\u003e\n\u003cp data-start=\"2036\" data-end=\"2079\"\u003e\u003cstrong data-start=\"2036\" data-end=\"2047\"\u003eSafety:\u003c\/strong\u003e CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2080\" data-end=\"2144\"\u003e\n\u003cp data-start=\"2082\" data-end=\"2144\"\u003e\u003cstrong data-start=\"2082\" data-end=\"2099\"\u003ePower supply:\u003c\/strong\u003e Li-ion rechargeable battery, mains charger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2145\" data-end=\"2208\"\u003e\n\u003cp data-start=\"2147\" data-end=\"2208\"\u003e\u003cstrong data-start=\"2147\" data-end=\"2159\"\u003eDisplay:\u003c\/strong\u003e large LCD with backlight and graphical support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2209\" data-end=\"2297\"\u003e\n\u003cp data-start=\"2211\" data-end=\"2297\"\u003e\u003cstrong data-start=\"2211\" data-end=\"2238\"\u003eMemory \u0026amp; Communication:\u003c\/strong\u003e 8 GB internal memory, USB \u0026amp; Bluetooth® for data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2298\" data-end=\"2328\"\u003e\n\u003cp data-start=\"2300\" data-end=\"2328\"\u003e\u003cstrong data-start=\"2300\" data-end=\"2311\"\u003eWeight:\u003c\/strong\u003e approx. 4.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2330\" data-end=\"2333\"\u003e\n\u003ch2 data-start=\"2335\" data-end=\"2362\"\u003e\u003cstrong data-start=\"2338\" data-end=\"2362\"\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2363\" data-end=\"2553\"\u003e\n\u003cli data-start=\"2363\" data-end=\"2412\"\u003e\n\u003cp data-start=\"2365\" data-end=\"2412\"\u003eHigh-voltage test leads (red\/black, shielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2413\" data-end=\"2432\"\u003e\n\u003cp data-start=\"2415\" data-end=\"2432\"\u003eCrocodile clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2433\" data-end=\"2456\"\u003e\n\u003cp data-start=\"2435\" data-end=\"2456\"\u003eGuard terminal lead\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2457\" data-end=\"2491\"\u003e\n\u003cp data-start=\"2459\" data-end=\"2491\"\u003eMains adapter + charging cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2492\" data-end=\"2509\"\u003e\n\u003cp data-start=\"2494\" data-end=\"2509\"\u003eTransport bag\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2510\" data-end=\"2553\"\u003e\n\u003cp data-start=\"2512\" data-end=\"2553\"\u003eUser manual and calibration certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Metrel","offers":[{"title":"Default Title","offer_id":49522339315905,"sku":"MTMI3211","price":5349.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/files\/MI-3211-TeraOhmHP-10-kV_Ang.webp?v=1757082033"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2967\/3946\/collections\/MI_3210_TeraOhmXA_10_kV.jpg?v=1519988441","url":"https:\/\/duncaninstr.com\/collections\/insulation-tester\/20000v.oembed","provider":"Duncan Instruments Canada Ltd","version":"1.0","type":"link"}