Fluke 1555/KIT Insulation Resistance Tester Kit, 10kV
Regular price
$ 7,800.00 CAD
Sale
Voltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600V AC or DC for increased user safety. With selectable test voltages in 50V steps from 250 to 1000V and 100V steps above 1000V. Complete kit including test cable set.
Evaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. Add this instrument to your preventive or predictive maintenance programs to identify potential equipment failures before they occur.
Features
- Test voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user-defined label for easy recall
- Long battery life gives the user over 750 tests between charges
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
Applications
- Building Automation
- Commercial
- Defense
- Military and Aerospace
- HVAC/R
- Industrial
- Maintenance and Repair
- Mining
- Oil and Gas
- Motor Drive and Control
Specifications
Insulation Resistance | ||
Test voltage (DC) | Range (DC) | Accuracy (± reading) |
250 V | < 250 kΩ 250 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ |
Unspecified 5% 20% Unspecified |
500 V | < 500 kΩ 500 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ |
Unspecified 5% 20% Unspecified |
1000 V | < 1 MΩ 1 MΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ |
Unspecified 5% 20% Unspecified |
2500 V | < 2.5 MΩ 2.5 MΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ |
Unspecified 5% 20% Unspecified |
5000 V | < 5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ |
Unspecified 5% 20% Unspecified |
10000 V | < 10 MΩ 10 MΩ to 200 GΩ 10 GΩ to 2 TΩ > 2 TΩ |
Unspecified 5% 20% Unspecified |
Leakage Current Measurement | ||
Range | 1 nA to 2 mA | |
Accuracy | ± (5 % + 2 nA) | |
Capacitance Measurement | ||
Range | 0.01 uF to 15.00°F | |
Accuracy | ± (15 % rdg + 0.03°F) | |
Timer | ||
Range | 0 to 99 minutes | |
Accuracy | Resolution Setting: 1 minute Indication: 1 second | |
Live Circuit Warning | ||
Range | Warning Range 30 V to 660 V AC/DC, 50/60 Hz | |
Accuracy | Voltage Accuracy ± (15 % + 2 V) | |
Additional | ||
Bar Graph Range | 0 to 1 TΩ | |
Insulation Test Voltage Accuracy | -0 %, +10 % at 1 mA load current | |
Induced AC Mains Current Rejection | 2 mA maximum | |
Charging Rate for Capacitive Load | 5 seconds per °F | |
Discharge Rate for Capacitive Load | 1.5 s/°F |
What's included with the Fluke 1555/KIT
- Insulation Resistance Tester
- Certificate of Calibration
- Test cables with alligator clips (red, black, green)
- Infrared adapter with interface cable
- FlukeView® Forms Basic CD-ROM
- AC power cord
- English manual
- User's manual on CD-ROM
- Quick reference card
- Software license agreement
- Registration card
- FlukeView® Forms installation guide
- USB-IR cable installation guide
- Heavy duty alligator clip leads
- Carrying Case