Fluke 1555 FC Kit w/IR3000 10 kV Insulation Tester Kit with IR3000 FC Connector
Regular price
$ 6,000.00 CAD
$ 10,005.00 CAD
Sale
The Fluke 1555C Tester together with the IR3000 FC connector and Fluke Connect App allow users to perform advanced insulation testing by wirelessly transfering test results from the tester to Fluke Connect which eliminates error-prone paperwork and saves your technicianÍs time. Kit includes industrial hard case and high voltage test lead.
This insulation resistance tester offers digital insulation testing up to 10 kV, making it ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables. It can conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, it is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.
Features
- Test voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™
- CAT III 1000 V, CAT IV 600 V safety rating
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
- 3-year warranty
Benefits
When combined with the ir3000FC1550 Connector and Fluke Connect, it provides three unique benefits that increase work efficiency and safety:
- Real-time trending – show a graph of current insulation test data on your phone, rather than trying to interpret a hard-to-read set of changing numbers on the tester itself. Makes it easy to see if your test values are shifting in the right direction. You no longer need to import values into a separate spreadsheet
- Remote configuration and operation of your tester – take full control of your tester through your smartphone. Remote start and stop allows the user to move out of potentially hazardous zones before engaging tests and monitoring results
- Simple, quick report creation using drag and drop tools – faster, more understandable and more accurate reporting for the maintenance manager or a customer contracting the test procedure
Applications
- General purpose electrical maintenance
- Preventive and predictive maintenance
- Troubleshooting
Fluke FLUKE-1555 FC KIT Specifications
Insulation Resistance | ||
Test voltage (DC) | Range (DC) | Accuracy (± reading) |
250 V | < 250 kΩ 250 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ |
Unspecified 5% 20% Unspecified |
500 V | < 500 kΩ 500 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ |
Unspecified 5% 20% Unspecified |
1000 V | < 1 MΩ 1 MΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ |
Unspecified 5% 20% Unspecified |
2500 V | < 2.5 MΩ 2.5 MΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ |
Unspecified 5% 20% Unspecified |
5000 V | < 5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ |
Unspecified 5% 20% Unspecified |
10000 V | < 10 MΩ 10 MΩ to 200 GΩ 10 GΩ to 2 TΩ > 2 TΩ |
Unspecified 5% 20% Unspecified |
Leakage Current Measurement | ||
Range | 1 nA to 2 mA | |
Accuracy | ± (5 % + 2 nA) | |
Capacitance Measurement | ||
Range | 0.01 uF to 15.00°F | |
Accuracy | ± (15 % rdg + 0.03°F) | |
Timer | ||
Range | 0 to 99 minutes | |
Accuracy | Resolution Setting: 1 minute Indication: 1 second | |
Live Circuit Warning | ||
Range | Warning Range 30 V to 660 V AC/DC, 50/60 Hz | |
Accuracy | Voltage Accuracy ± (15 % + 2 V) | |
Additional | ||
Bar Graph Range | 0 to 1 TΩ | |
Insulation Test Voltage Accuracy | -0 %, +10 % at 1 mA load current | |
Induced AC Mains Current Rejection | 2 mA maximum | |
Charging Rate for Capacitive Load | 5 seconds per °F | |
Discharge Rate for Capacitive Load | 1.5 s/°F |
What's included with the Fluke FLUKE-1555 FC KIT
- Insulation Resistance Tester
- IR3000FC1550 Connector
- Certificate of Calibration
- Test Cables with Alligator Clips
- Infrared adapter with interface cable
- FlukeView® Forms Basic CD-ROM
- AC Power Cord
- English Manual
- Users Manual on CD-ROM
- Quick Reference Card
- Software License Agreement
- Registration Card
- FlukeView® Forms Installation Guide
- USB-IR Cable Installation Guide
- Heavy Duty Alligator Clip Leads
- IP67 Hard Carrying Case