Fluke 1577 Insulation Multimeter
Regular price
$ 1,240.00 CAD
Sale
Compare with:
This insulation multimeter comes in a compact and handheld design, which enables maximum versatility for both troubleshooting and preventative maintenance. Additionally, this product is also rugged, reliable, and easy to use.
- Auto discharge of capacitive voltage
- AC/DC voltage
- DC millivolts
- AC/DC milliamps
- Continuity
- Auto power off to save battery power
- True RMS
- Large display with backlight
- Live circuit detection prevents insulation test if voltage <30 V is detected for added user protection
- CAT III 1000V, CAT IV 600V measurement category
- Accepts magnetic hanging system to free your hands for other work (sold separately)
Applications
- Troubleshooting
- Preventative maintenance
Fluke 1577 Specifications
Voltage DC | |
Maximum Voltage | 1000 V |
Accuracy | ±(0.2% + 2) |
Maximum Resolution | 0.001 V |
Voltage AC | |
Maximum Voltage | 1000 V |
Accuracy | ±(2% + 3) |
Maximum Resolution | 0.1 mV |
Current DC | |
Maximum Amps | 400 mA |
Amps Accuracy | ±(1.0% + 2) |
Maximum Resolution | 0.01 mA |
Current AC | |
Maximum Amps | 400 mA |
Amps Accuracy | ±(2.0% + 2) |
Maximum Resolution | 0.01 mA |
Resistance | |
Maximum Resistance | 50 MΩ |
Accuracy | ±(1.2% + 2) |
Maximum Resolution | 0.1 Ω |
Insulation Test | |
Minimum Test Current at 1 kΩ/V | 1 mA |
Test Voltages | 500, 1000 V |
Maximum Resistance per Test Voltage | 50 V 100 V 250 V 500 V 1000 V: 600 MΩ |
Maximum Resolution per Test Voltage | 50 V: 0.01 MΩ 100 V: 0.01 MΩ 250 V: 0.1 MΩ 500 V: 0.1 MΩ 1000 V: 0.1 MΩ |
Accuracy per Test Voltage | 50 V: ±(3% + 5) 100 V: ±(3% + 5) 250 V: ±(1.5% + 5) 500 V: ±(2.0% + 5) 1000 V: ±(2.0% + 5) |
Environmental Specifications | |
Operating Temperature | -4 to 131°F (–20 to 55°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Humidity (Without Condensation) | 0 to 95%: 50 to 86°F (10 to 30°C) 0 to 75%: 86 to 104°F (30 to 40°C) 0 to 40%: 104 to 131°F (40 to 55°C) |
Operating Altitude | 6561.68' (2000 m) |
Mechanical and General Specifications | |
Battery Life Alkaline | Meter use: 1000 hours Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off |
Dimensions | 7.99 x 3.94 x 1.97" (203 x 100 x 50 mm) (with holster) |
Weight | 22 oz (624 g) |
IP Rating | IP40 |
Safety Specifications | |
Overvoltage Category | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
Agency Approvals | 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
What's included with the Fluke 1577
- Multimeter
- Remote Probe
- Test Leads
- Alligator Clips
- Carrying Case
- User Documentation