Fluke 1577 Insulation Multimeter – Duncan Instruments Canada Ltd
Fluke 1577 Insulation Multimeter
Fluke 1577 Insulation Multimeter
Fluke 1577 Insulation Multimeter
Fluke 1577 Insulation Multimeter

Fluke 1577 Insulation Multimeter

Regular price $ 1,240.00 CAD Sale

Compare with:

This insulation multimeter comes in a compact and handheld design, which enables maximum versatility for both troubleshooting and preventative maintenance. Additionally, this product is also rugged, reliable, and easy to use.

  • Auto discharge of capacitive voltage
  • AC/DC voltage
  • DC millivolts
  • AC/DC milliamps
  • Continuity
  • Auto power off to save battery power
  • True RMS
  • Large display with backlight
  • Live circuit detection prevents insulation test if voltage <30 V is detected for added user protection
  • CAT III 1000V, CAT IV 600V measurement category
  • Accepts magnetic hanging system to free your hands for other work (sold separately)

Applications

  • Troubleshooting
  • Preventative maintenance

Fluke 1577 Specifications

Voltage DC
Maximum Voltage 1000 V
Accuracy ±(0.2% + 2)
Maximum Resolution 0.001 V
Voltage AC
Maximum Voltage 1000 V
Accuracy ±(2% + 3)
Maximum Resolution 0.1 mV
Current DC
Maximum Amps 400 mA
Amps Accuracy ±(1.0% + 2)
Maximum Resolution 0.01 mA
Current AC
Maximum Amps 400 mA
Amps Accuracy ±(2.0% + 2)
Maximum Resolution 0.01 mA
Resistance
Maximum Resistance 50 MΩ
Accuracy ±(1.2% + 2)
Maximum Resolution 0.1 Ω
Insulation Test
Minimum Test Current at 1 kΩ/V 1 mA
Test Voltages 500, 1000 V
Maximum Resistance per Test Voltage 50 V
100 V
250 V
500 V
1000 V: 600 MΩ
Maximum Resolution per Test Voltage 50 V: 0.01 MΩ
100 V: 0.01 MΩ
250 V: 0.1 MΩ
500 V: 0.1 MΩ
1000 V: 0.1 MΩ
Accuracy per Test Voltage 50 V: ±(3% + 5)
100 V: ±(3% + 5)
250 V: ±(1.5% + 5)
500 V: ±(2.0% + 5)
1000 V: ±(2.0% + 5)
Environmental Specifications
Operating Temperature -4 to 131°F (–20 to 55°C)
Storage Temperature -40 to 140°F (-40 to 60°C)
Humidity (Without Condensation) 0 to 95%: 50 to 86°F (10 to 30°C)
0 to 75%: 86 to 104°F (30 to 40°C)
0 to 40%: 104 to 131°F (40 to 55°C)
Operating Altitude 6561.68' (2000 m)
Mechanical and General Specifications
Battery Life Alkaline Meter use: 1000 hours
Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off
Dimensions 7.99 x 3.94 x 1.97" (203 x 100 x 50 mm) (with holster)
Weight 22 oz (624 g)
IP Rating IP40
Safety Specifications
Overvoltage Category Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency Approvals 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V


What's included with the Fluke 1577

  • Multimeter
  • Remote Probe
  • Test Leads
  • Alligator Clips
  • Carrying Case
  • User Documentation
  • Three-Year Warranty